Original source · versioned page text
2756-500
Attached to the e-mail RAL21/0016 - Response to Council's Information Request.
WATER LIVE WORKS CONNECTION
UNITYWATER TO INSTALL NEW 20mm WATER
METER FOR LOT 1 AT DEVELOPERS EXPENSE
PAD 9.2m
EXISTING WM
TO REMAIN .
|
SEWER LIVE CONNECTION 4
EXISTING SEWER CONNECTION TO B
| ‘CAPPED AND DECONISSIONED AT BY
PRIVATE WORKS AT DEVELOPERS
EXPENSE
LIVE SEWER WORKS TABLE
UNITYWATER PRIVATE WORKS TO CAP AND DECOMISSION EXISTING
CONNECTION FOR 1/RP128401 AT DEVELOPERS EXPENSE
UNITYWATER PRIVATE WORKS TO BREAK INTO 1/1 AND CONSTRUCT
2A | 150mm STUB TEMPORARY CAPPED PRIOR TO START OF
CONSTRUCTION
CONTRACTOR OR PRIVATE WORKS TO INSTALL LINE 1 UPTO 3m
FROM EXISTING 1/1
2¢_| AFTER SUCCESSFUL ON MAINTENANCE, NOTIFY UNITYWATER,
UNITYWATER TO MAKE LIVE BY CONSTRUCTING REMAINDER OF
WORKS OR CONTRACTOR TO COMPLETE WORKS AS DIRECTED BY
UNITYWATER AT DEVELOPERS EXPENSE
NOTE:
ALL LIVE WORKS ON EXISTING SEWER MAINS ARE TO BE CARRIED OUT BY
UNITYWATER AT THE DEVELOPER'S EXPENSE, OR AS DIRECTED BY UNITYWATER
‘ALL WORKS ON EXISTING WATER MAINS TO BE CARRIED OUT BY UNITYWATER AT THE
DEVELOPER'S EXPENSE,
EXISTING SERVICES SHOWN ARE BASED ON DIAL BEFORE YOU DIG RECORDS AND ARE
‘TO BE CONFIRMED PRIOR TO THE COMMENCEMENT OF CONSTRUCTION WORKS.
180 | 2662095 (1/2)
180 | 2662498 (1/1)
HDD DRILLING
‘SEWER TO BE TUNNEL BORED UNDER
GODWIN ST AND GUMNUT CT INTERSECTION
NOTE:
REINSTATE ALL CONCRETE PATHS AND
VERGE AREAS AFTER COMPLETION OF
CONSTRUCTION
PROPOSED FEATURES
[SEWER LIVE CONNECTION 2
EGRTRACTOR TO CONSTRTCT UPTO
FOU eNSIINS
CONNECTION TO EXSTNG MANHOLE BY
UNITYWATER PRIVATE WORAS ORAS
DRECTED BY UW AT DAELOPENS COST
LEGEND
EXISTING FEATURES
OVERALL RP BOUNDARY
— —— CADASTRAL EASEMENT
-- —— CADASTRAL RP BOUNDARY
ROAD KERB & CHANNEL
— -L -6 — — — Wi WATER RETICULATION
— — — vi — —W— WATER RETICULATION DBYD
— — —s -€— —5 — SEWER RETICULATION
— — —s -€— —s — SEWER RETICULATION DBYD
— — —#iOH-o—— OVERHEAD ELECTRICAL
———1t———1 — TELSTRA
CONCRETE
Ss DN180 uPVC SN8 SEWER MAIN
@ ‘SEWER STRUCTURE NUMBER
‘SEWER HOUSE CONNECTION BRANCH
Hos STANDARD.
KBE ELECTRICAL OFFSET
HEEB BUILD TO BOUNDARY OFFSET
—--- ‘WMH WATER METER
— — — — NATURAL CONTOUR
UNITYWATER TO BREAK IN
AT DEVELOPERS EXPENSE
MAKE GOOD
EXISTING BENCHING
CONNECTION DETAIL 1/1
S
NT
MANHOLE DETAIL 4/1
‘SCALENTS
SCALE 1:500 03,
CONTOUR
SUNSHINE COAST OFFICE NORTHLAKES OFFICE “8D. 17%
Building A, Level 1 Conporate Suite A, Bid 2 ~
6 Innovaton Parkway, 2-4 Finders Parade,
Birtinya 4575, Qld North Lakes 4509, id
‘wa ContourCE comau
Ph. (07) $493 9777
[email protected] au
PROPOSED RESIDENTIAL DEVELOPMENT
AT 108 GOODWIN ST, TEWANTIN
FOR STEPHAN VAN DER WALT
PLAN TITLE:
DEVELOPMENT PLAN WATER AND SEWER
SERVICES
FOR APPROVAL - NOT FOR CONSTRUCTION
PLAN DETAILS: PLAN AMENDMENTS:
Designed: anf Rev | Date | Comment Tired] Chesed
Drawn BH
Checked sc
Datum: AND
Date ‘Aue 2024
"© Teagan Copy, Ola an oth pups ofan
‘sy means be eae, sored i arestovlaytn oan
Be vod far censuston wth! po won approval
po crtlon roretoad
with pew ps
ha CepyraN Reo parle nay nny nop
sion of ComoutCosulingEngneas Th lan sl at
2756 - 500 REVISION: ==
See the original
The page text is free to read. Viewing or downloading an original file needs an account.