Council archive · source document
3278 Colour 250717 · MCU17/0523
Attached to the e-mail Information response - MCU17/0523.
ROOF LEVEL 1 GROUND ROOF LEVEL 1 GROUND ROOF 939 17 ret 55 W—-- [#20 | 920 | | | iho | ' Moe | O Bn Bn |, 920 Shr | we Bth | | LEVEL 1 [DP Tt 1 1 | i i | | | | 620) ! | | [i #20 EXISTING WATER METER | ELECTRIGAL WC Bn L'DRY So 1 lHws| | [1 © — HC <a} Bn O Jtroot He O Sk Wc Shr ' | LL | | y GROUND 20 920 1\920 L v1 --------- L---4 NX Lf | | ! ! NOTE: aaa LI © THE AUTHOR HAS STRONGLY SUGGESTED A ~ OQ an I I DUAL HOT WATER SYSTEM FOR THIS ae Shr I I LAYOUT. THE SHOWN HOT WATER SYSTEM 920 HOT >60deg LINE TO WN 4 | KITCHEN IS NOT THE PREFERRED SOLUTION OF THE — SINKS I AUTHOR AND THE AUTHOR CAN NOT BE ONES TO EYCIENE <50deg \ Sk MADE RELIABLE FOR DEFICIENCIES I OCCURRING DURING THE OPERATION OF FIXTURES BASEMENT es BASEMENT THIS HOT WATER SYSTEM. WATER RETICULATION DIAGRAMATIC Ss 1 ROOF | FIXTURE DISCHARGE | PIPE. DIA. 3 | oO! Bth 40 8| QI Bn 40 | | Shr 50 | wc 100 Sk 50 | S$ uT 50 | | 2 Safe tray 50 | | FW 65 uno Bn Bn | 100 under ground Bth va IWC |FWG Shr ' NOTE: ES boo ALL STACK JUNCTION SHALL 1 COMPLY WITH AS3500.2.2013, | CLAUSE 6.6.5 OPPOSED CONNECTIONS i |_-AAV UNDER BENCH AND RESTRICTED ZONES | KITCHEN Sk | 9100 Lt Bn | Bn Shi cos [TC we lL FWG td L Fwe hr NYPICAL 865 IWC cue I — KO =E= 9100 9100 9100 BAR Sk Bn Sh 1 ORG cos IIc we Shr \y Fwe | ORG T BASEMENT | | ~~ F— 100uPVC 9100 \ \ 33 FU 9 100uPVC Note: Install strainer and PLV set to 500 kPa on incoming cold water, where SANITARY DRAINAGE ELEVATION SINGLE STACK SYSTEM mains press exceeds 680 kPa CW to fixtures oe Isolating valve NRV po --—HW yempering ‘<i Strainer at 50 deg at 60 deg to Sk & Ldry where applicable Hot Water ) System Temp/Press relief valve position o’flow directly over safe tray outlet 25 ~ (.25 Vl 50 | SS No trap reqd if To FWG 950 less than 1200 from FWG LEVEL 1 GROUND BASEMENT SPECIFICATIONS ITEM DESCRIPTION MANUFACTURER NOTES FS ER SYSTEM ELECTRICAL STORAGE RHEEM RHEEM PLUS 315 FOG ATER SYSTEM ELECTRICAL STORAGE RHHEM RHEEM PLUS 250 ror wre woo | aoa REE a we he DOWN PIPES 8150 & 4100 c.0.8. REFER DETAIL ORG REFER DETAIL DISCHARGE OF POOL BACKWASH REFER DETAIL STORMWATER § INFILTRATION CHAMBER CUSTOM MADE REFER DETAIL CONCRETE & BLOCKWORK | REFER DETAIL NOTE: ALL SPECIFIED MANUFACTURERS SHALL BE AS NOTED OR EQUAL APPROVED. SIGNED BY THE PRINCIPAL AND SENIOR DESIGN ENGINEER DR.—ING. REINHOLD KOENNING RPEQ7023 MSC, PHD, MEAUST, AHSCA DATE AS PER TITLE BLOCK DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED FOR ASSESSMENT, TENDERING AND CONSTRUCTION. [Amd Description Date Issue Notes Date For Development Approval For Building Approval For Tender x 21-07-17 For Construction xX 21-07-17 As Constructed E Hydraulic 3: \- contact: Reinhold Koenning MigAust AHSCA PO Box 181 Moffat Beach, QLD, 4551 email: [email protected] PH: (07) 5491 4333 CLIENT : WEIER & COPLEY ARCHITECT : LL CHRIS CLOUT DESIGN (PRosect: 26/512 DAVID LOW WAY 26 MARCUS DUNES COURT CASTAWAYS BEACH A DRAWING TITLE: ELEVATIONS ss w SPECIFICATIONS | Design] #H.|checked] h [Date | 21-07-17 | Dwg. No. ‘AMD. SCALE : N/A ON At UNo.| 5 of 5 3278-5 J RPD:— LOT 26 SP 111721
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
3278 COLOUR 250717.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.