APPENDIX 4 – SLOPE STABILITY REPORT




P a g e | 44                          TOWN PLANNING REPORT


[OCR of page images]
 

APPENDIX 4 — SLOPE STABILITY REPORT

 

 

Page |44 TOWN PLANNING REPORT

 

 
Full text of the other 35 pages

Page 2

                                                                                                                   [email protected]
                                                                                                                         arcosgroup.com.au
                                                                                                                        ABN 51 640 311 841




 Attention: Mark and Elle Bennet                                                                                             27 Mar 2025
 By Email                                                                                        ARCOS PROJECT:AG2500070.00
                                                                                                             Report 01 Revision Rev A
Report on Geotechnical Investigation
Proposed Residential Development
19 Attunga Heights, Noosa Heads
Arcos Unit Group Pty Ltd (Arcos Group) has undertaken a geotechnical investigation for the above project and client.
SUMMARY OF INVESTIGATION

                     Results of Australian Geomechanic Society Landslide Risk Assessment
                                                                    Low
Note:     The above is a summary of the detailed investigation results discussed within this report. The entire report must be read,
          understood and kept in entirety.




Senior Geotechnical Engineer




Andre Dos Santos B.Eng (Civ), MIEAust, RPEQ,
CPEng, NER
[email protected]
For and On Behalf of Arcos Group




Sunshine Coast | Brisbane | Gold Coast

Page 3

                                                                                                        ABN 51 640 311 842
                                                                                                        arcosgroup.com.au
                                                                                       Sunshine Coast | Brisbane | Gold Coast




1         INTRODUCTION
Arcos Unit Group Pty Ltd (Arcos Group) was commissioned to undertake a geotechnical investigation for the project
at the location described on the title page of this report.
This report outlines the results of the investigation, laboratory testing, analysis, and interpretive reporting on the
following items:
 Review of the existing slope stability hazards, their attributed risks and impacts of the proposed development in
  alignment with the practices set out within the Australian Geomechanics Society guidelines; and,
 Provide recommendations from a geotechnical context that will avoid or reduce any potential instability.
This report must be kept in entirety. The use of this document is exclusively undertaken in accordance with our terms
and conditions.

2         REGIONAL GEOLOGY
The site is in an area underlain by Pleistocene aged parabolic sand dunes, which typically comprises “quartz sand”.

3         EXISTING STABILITY RISK
Local authorities prepare mapping tools to aid in assessing potential slope stability requirements. The mapping tools
are a “high level” approach where the site specific investigations are specific to a particular site/allotment. It is
important to note that where a site specific investigation and slope stability assessment are undertaken, they take
precedence.
Reference to the available overlays for the area show the site has been initially mapped as “Moderate” in terms of
landslide hazard.

4         GEOTECHNICAL INVESTIGATION
A soil test has recently been undertaken by Australian Soil Investigations (ASI). The soil test comprised the drilling
of two bores to between 2 m and 3 m depth using hand-held auger equipment. In summary, the subsurface conditions
encountered in the bores generally comprised loose to medium dense silty sand (which is consistent with the
published geology). No groundwater seepage was encountered in the bores; however, it should be noted that
groundwater is transient and can fluctuate with seasonal changes and human influences (such as broken
infrastructure). A copy of the ASI report is attached.

5         WALKOVER ASSESSMENT
Geotechnical comments are based on the factual findings of the investigation, best practice, local experience,
published correlations; however, are fundamentally founded in opinion and this should be considered.
A site walkover assessment was undertaken by a Geotechnical Engineer on 26 March 2025. The site is located on
the western flank of a hill within the Yunaman Bushland Reserve. The site is occupied by an existing brick veneer
dwelling and an empty in-ground pool at the rear. These structures appeared to be stable, and no visible signs of
distress (associated with downhill slope movements) were observed. Topographically, the site is initially relatively flat
and level from the road but then gently slopes down towards the western boundary. Slopes angles are moderate and
range between 5° and 10°. No obvious signs of disturbed ground, tension cracks or hummocks were noted at the
site and surrounding area during the walkover assessment. A variety of vegetation ranging from small shrubs to
mature trees were observed. The mature trees at the site were all observed to be typically vertical with no misshapen
or curved trunks. Misshapen or curved trunks are usually good indicators for previous slope instability.



Sunshine Coast | Brisbane | Gold Coast

Page 4

                                                                                                         ABN 51 640 311 842
                                                                                                         arcosgroup.com.au
                                                                                        Sunshine Coast | Brisbane | Gold Coast




 Figure 1: Front of site                                      Figure 2: Rear of site


6         AGS ASSESSMENT
Landslides are caused where a soil or rock mass has a decrease in strength, usually attributed to groundwater,
resulting in the material not being able to maintain its own self-weight resulting in a slope failure.
The Australian Geomechanics Society (AGS) developed a set of tools and procedures for assessing the stability of
a slope. The tools and procedures presented with the AGS documentation form the basis of the assessment
undertaken herein and their documentation is attached for reference.
The guidelines also identify that the regulator typically sets the standard for levels of tolerable risk. AGS defines
tolerable risk as “risks within a range that society can live with so as to secure certain benefits. It is a range of risk
regarded as non-negligible and needing to be kept under review and reduced further if practicable”.
The guides suggest that areas of moderate or greater risk should not be developed unless a rigorous remediation
plan be implemented to reduce the area to a level of Acceptable Risk. AGS defines acceptable risk as “risk which
everyone affected is prepared to accept. Action to further reduce such risk is usually not required unless reasonably
practicable measures are available at low cost in terms of money, time and effort.”.
AGS suggest that regulators generally accept risk levels of “low” or lower as a level of acceptable risk.
AGS prepared a semi-quantitative assessment tool for determining the level of risk for a site. The tool separates the
potential hazards for a site, from a stability context, and rates them with a level of risk frequency. The multiplication
of these individual risk frequency summates as the risk frequency rating which is then measured against the levels
of risk nominated by AGS.
The results of this analysis are shown in Table 1.




Sunshine Coast | Brisbane | Gold Coast

Page 5

                                                                                                           ABN 51 640 311 842
                                                                                                           arcosgroup.com.au
                                                                                          Sunshine Coast | Brisbane | Gold Coast




TABLE 1: AGS ASSESSMENT

                Hazard                         Likelihood               Consequence                      Risk Level
              Global failure                      Rare                      Medium                            Low
         Creep in shallow sand                   Possible                 Insignificant                    Very Low
  Rotational or translational slide down         Unlikely                    Minor                            Low
                 the slope

  Failure of engineered retaining walls           Rare                      Medium                            Low


Based on the results of the AGS assessment, the perceived risk to property based on the conditions encountered
and information available at the time of the assessment is “Low”.

7         HILLSIDE CONSTRUCTION
The following works should be implemented in addition to other items highlighted within this document. These points
are considered to be typical good hillside construction practice as explained in attached documentation:
 Footings should be founded into medium dense (or better) silty sand.
 Fill should be limited to no more than 1.5 m and should be step keyed into the existing slope. The fill should be
  formed at no steeper than 3H:1V, unless retained by an engineered retention system. All fill should be placed in
  accordance with AS3798.
 The design and integrity of retaining structures will need to be confirmed to adhere to good hillside construction
  methodologies including being globally stable (ie. designed to achieve a minimum safety factor of 1.5 against
  global instability).
 All stormwater and surface water is to be discharged by an approved stormwater drainage system.
 Avoid leakage from underground services and drains. Any leaking services or blocked drains should be remedied
  promptly.
 Erosion protection of cut and fill batters will be required. Batters should incorporate crest and toe drainage. Batters
  should be vegetated appropriately to minimise erosion.
 Overland flow paths will need to be carefully directed to approved outlets to minimise erosion possibility.

8         GEOTECHNICAL RECOMMENDATIONS
The following sections details specific geotechnical constraints or recommendations in addition to general hillside
construction notes.


8.1       FOOTINGS
In accordance with industry standards, a geotechnical engineer from Arcos should undertake the testing within the
footings to confirm that the encountered material is in alignment with the adopted parameters and assumptions
provided within this report. Where this does not occur, Arcos cannot be held liable for any of the information presented
within this report.
All footings will need to be designed to accommodate potential ground surface movement, settlement values and
any additional settlement values associated with the placement of new fill.
Settlement for suitably sized and designed high level footings should be in the order of 1-2% of the width of the
footing.



Sunshine Coast | Brisbane | Gold Coast

Page 6

                                                                                                       ABN 51 640 311 842
                                                                                                       arcosgroup.com.au
                                                                                      Sunshine Coast | Brisbane | Gold Coast




If footings are located adjacent to an underground service or other obstruction that is not homogenous with the
founding strata, the footing should be extended a minimum 0.3 m below an imaginary line projected at a 45 degree
angle from the lowest point of the service/obstruction. This is depicted graphically for reference:




Where footings found into medium dense silty sand, they may be dimensioned for a maximum allowable bearing
pressure of 100 kPa. Based on the borelogs, the above material is encountered at approximately 1.1 m to 1.3 m
depth below existing surface levels at the time of the investigation.
The ultimate geotechnical end bearing and shaft adhesion parameters are presented in Table 2 for deep level
footings where high level footings are not suitable. The values given will need to reduced by applying a suitable
geotechnical strength reduction factor (Φg) for limit state or divided by a suitable factor of safety for working stress
methods. The Φg should be selected by the designer.
TABLE 2: DEEP LEVEL FOOTING – ULTIMATE GEOTECHNICAL PARAMETERS (LONG PILE)

                  Material                          Bored               Bored            Screw               Screw

                                                  Fb (kPa)             Fs (kPa)        Fb (kPa)             Fs (kPa)
           Medium dense silty sand                    450                 5                450                  NR
 Notes: Fb = Base Bearing (Ultimate); Fs = Shaft Adhesion (Ultimate)


The upper 1 m of soil profile should be ignored in shaft calculations for bored piles to allow for shrinkage cracks. Due
to installation disturbance, shaft adhesion should be ignored for steel screw piles. The values presented in Table 2
assume that the material equal to four pile diameters below the base of any footings is as strong or stronger.
Settlement values are subjected to a variety of factors; however, a properly designed and constructed pile should
have a serviceability settlement between 1% and 2% of its’ diameter.
Lateral capacity of steel screw piles could be increased by constructing concrete pile caps or by using proprietary
head attachments which are dragged into the soil providing additional lateral resistance at the pile head. It should
be noted that the lateral support is generally limited and is generally suited to structures that can accommodate some
lateral movement.




Sunshine Coast | Brisbane | Gold Coast

Page 7

                                                           ABN 51 640 311 842
                                                           arcosgroup.com.au
                                          Sunshine Coast | Brisbane | Gold Coast




ATTACHMENTS
About Your Geotechnical Report
Interpretation of the Subsurface Sheets
Practice Note Guidelines
Client Supplied Information




Sunshine Coast | Brisbane | Gold Coast

Page 8

                                                                                                    ABN 51 640 311 842
                                                                                                    arcosgroup.com.au
                                                                                   Sunshine Coast | Brisbane | Gold Coast




                                         ABOUT YOUR GEOTECH REPORT



                                                            Reporting
These notes have been provided to clarify and               The report has been prepared and reviewed by
enhance the reader’s understanding of the                   suitably qualified and experienced persons. The
terminology used throughout the report, and also to         persons draw on previous experience, local
identify where limitations exist. All investigations are    knowledge, published literature, and otherwise
undertaken based on budgetary constraints which             standard engineering approaches and principals. The
impart a level of uncertainty as a result of limiting the   context of which the report has been prepared for must
amount of investigation undertaken.                         be considered and if the context changes, due
                                                            consideration should be given to the possibility that the
                                                            report is no longer considered relevant and review by
Copyright                                                   Arcos Unit Group Pty Ltd must be undertaken.
This report remains the property of Arcos Unit Group        Arcos Unit Group Pty Ltd undertakes quality
Pty Ltd at all times unless ownership is transferred in     assurance checks in accordance with its’ quality
writing. It cannot be included in any documentation         system requirements; however, restrictions on the
without the express written permission of Arcos Unit        project outside of Arcos Unit Group Pty Ltd’s control
Group Pty Ltd                                               can result in unanticipated variations, changes in
                                                            policy or interpretation of said policies by the relevant
                                                            authority, or the actions of contractors subject to
Subsurface Report Sheets (Bores etc)                        commercial pressure.
The provided subsurface sheets are inherently an
interpretation undertaken by a suitably qualified and
experienced person; however, the reliability of the
                                                            Site Variations
provided information will rely on the method of             If site variations become evident at the time of
investigation. It is prudent to state that these sheets     construction or after the release of a report, Arcos Unit
only represent a very small percentage of the               Group Pty Ltd requests immediately notification. This
subsurface conditions across a particular project.          notification is proposed in order to assist in
                                                            remediation prior to any permanent structures or
It reasons that given the relatively small representation
                                                            design procedures are undertaken.
of the subsurface conditions for a project, spacial
variability between testing locations must be taken into
consideration including the orientation of strata           Collaboration
intersections.
                                                            Arcos Unit Group Pty Ltd strongly recommends open
The presence or lack of groundwater is usually stated       and collaborative communication about the use and
on the subsurface sheets; however, it must be noted         inherent interpretation of Arcos Unit Group Pty Ltd’s
that the measurements undertaken onsite are typically       report. Please contact the author of the report to
very inaccurate and if the presence or lack of              arrange for an obligation free discussion regarding the
groundwater will have any degree of affect on the           potential benefits of having geotechnical consultants.
project, additional groundwater monitoring techniques
should be employed such as groundwater monitoring
wells.




Sunshine Coast | Brisbane | Gold Coast

Page 9

                                                                                                           ABN 51 640 311 842
                                                                                                           arcosgroup.com.au
                                                                                        Sunshine Coast | Brisbane | Gold Coast




                                      Interpretation of the Subsurface Sheets


The terminology included on Arcos Unit Group Pty            the most important component. Typically, the strength
Ltd’s has been evolved from AS1726:2016. Typically          of rock is based on laboratory testing, tactile
a soil’s strength, colour, plasticity, grain size, other    assessment and other observations as relevant. The
inclusions, and moisture will be described. A rock’s        industry standard method for assessing the strength of
strength, weathering, colour, grain, and other              rock in the field is to use the point load strength index
inclusions are typically described.                         (AS4133.4.1). It is important to note that the point load
                                                            strength index does not take into consideration the
                                                            degree of fracturing of a rock mass which can both
Soil                                                        lower and increase the overall rock strength. The
Soil is typically described by the components that          strength of rock is broken down as follows:
make it up by percentage or whichever has a                 Very Low Strength (VLS)              < 2 MPa (UCS)
governing behaviour. The types and sizes reproduced         Low Strength (LS)                    2 to 6 MPa (UCS)
from AS1726 are:                                            Medium Strength (MS)                 6 to 20 MPa (UCS)
Boulder >200 mm                                             High Strength (HS)                   20 to 60 MPa (UCS)
Cobble 63 to 200 mm                                         Very High Strength (VHS)             60 to 200 MPa (UCS)
Gravel 2.36 to 63 mm                                        Extremely High Strength (EHS)        > 200 MPa (UCS)
Sand    0.075 to 2.36 mm                                    Very Low Strength (VLS)              < 0.1 Is(50)
Silty   0.002 to 0.075 mm                                   Low Strength (LS)                    0.1 to 0.3 Is(50)
Clay    < 0.002 mm                                          Medium Strength (MS)                 0.30 to 1.0 Is(50)
The strength of soil is usually assessed by suitably        High Strength (HS)                   1.0 to 3.0 Is(50)
experienced persons through the use of laboratory           Very High Strength (VHS)             3.0 to 10.0 Is(50)
test results, published literature, field assessments or    Extremely High Strength (EHS)        > 10.0 Is(50)
a combination of the above. The strength of soil is         The Is(50) values are based on a correlation between
characterised into either cohesive (clays and silts) or     the unconfined compressive strength (UCS) of 20.
cohesionless (sands and gravels) as shown below:            This value varies significantly and site specific testing
Cohessive Soil Strength Term                                must take precedence.

Very Soft            < 12.5 kPa                             Rock weathering is broken down as follows:
Soft                 12.5 to 25 kPa                         Extremely weathered (EW) Behaves as soil but rock structure
Firm                 25 to 50 kPa                                  evident
Stiff                50 to 100 kPa                          Highly weathered (HW) Colour and strength of original fresh rock
                                                                    is not recognisable. Decomposition of rock evident
Very Stiff           100 to 200 kPa
                                                            Moderately weathered (MW)    Defects are heavily stained with
Hard                 > 200 kPa
                                                                   rock mass showing signs of discolouration
Cohesionless Soils Strength Term (uncorrected Qc)           Slightly weathered (SW)     Some staining but minimal to no
Very Loose           <2 MPa                                          change in strength

Loose                2 to 5 MPa                             Fresh stained       (FS) Minor staining evident

Medium Dense         5 to 15 MPa                            Fresh rock        (FR) No change

Dense                15 to 25 MPa                           Rock fracturing is broken down as follows and can only
Very Dense           > 25 MPa                               be accurately described where undamaged
                                                            continuous sampling has been undertaken:
                                                            Fragmented (Fg)      Defect spacings < 20 mm
Rock
                                                            Highly Fractured (HF)    Defect spacings 20 to 50 mm
Rock is typically described by the components that          Fractured (Fr) Defect spacings 50 to 200 mm
make it up by percentage or whichever has a                 Slightly Fractured (SF) Defect spacings 200 to 1000 mm
governing behaviour. The strength of rock is typically      Unbroken (Ub) Defect spacings > 1000 mm




Sunshine Coast | Brisbane | Gold Coast

Page 10

                                                          ABN 51 640 311 842
                                                          arcosgroup.com.au
                                         Sunshine Coast | Brisbane | Gold Coast




Sunshine Coast | Brisbane | Gold Coast

Page 11

                                                          ABN 51 640 311 842
                                                          arcosgroup.com.au
                                         Sunshine Coast | Brisbane | Gold Coast




Sunshine Coast | Brisbane | Gold Coast

Page 12

                                                          ABN 51 640 311 842
                                                          arcosgroup.com.au
                                         Sunshine Coast | Brisbane | Gold Coast




Sunshine Coast | Brisbane | Gold Coast

Page 13

                                                          ABN 51 640 311 842
                                                          arcosgroup.com.au
                                         Sunshine Coast | Brisbane | Gold Coast




Sunshine Coast | Brisbane | Gold Coast

Page 14

                 SOIL TEST REPORT

                 Address         :   Lot 10 on RP89506
                                     19 Attunga Heights
                                     Noosa Heads

                 Client          :   M. Bennett

                 Date            :   26 March 2025

                 Report No       :   250131(S)




Phone: 0428 310 453
Email: [email protected]
Address: 174 Railway Road, Cooran Qld 4569
Australian Soil Investigations Pty Ltd
ABN: 11147854439

Page 15

1.0        INTRODUCTION:

Australian Soil Investigations has performed a limited site investigation and established a site classification in
accordance with AS 2870-2011 at the above address. This site classification report does not include an assessment
of Slope Stability or Landslide Risk. Fieldwork has been performed by an experienced geotechnician hand auguring
equipment.

            This report must be read and considered as a whole. All of our recommendations and appendices
            attached must be read, considered and followed by all people involved in this project including
            the client to ensure adequate long term performance of a footing system constructed on this site.
            If you are unsure of any of the requirements herein, you must seek clarification from this office.


2.0        SITE CLASSIFICATION:

After considering the results of our field investigation performed on 25/03/2025 we have classified this site as:


                                                        Class P

The classification has been calculated from test work performed on the soil profile encountered on the day of our
fieldwork and consideration of AS2870-2011. Any disturbance of the soil profile may result in a change to the
classification.

The ‘P’ classification relates to the poor bearing capacity and abnormal moisture conditions encountered during our
testing on site. Please refer to our definitions list appended to this report for further descriptions of these
characteristics.

The abnormal moisture conditions are due to the removal of the existing building, the presence and proximity of trees
to the allotment and existing trees located on the proposed construction area that will be removed.

With respect to potential surface movements through seasonal moisture variations, the site could be considered
equivalent to a class S site.

Site Classification: The site classification is calculated in accordance with the “AS2870-2011 Residential Slabs and
Footings-Construction” and relates to the estimation of Ys, “The characteristic surface movement” within reactive soil
profiles. The limits used for this classification are as follows:

                                  Predicted Surface Movement        Classification

                                  Ys = <=20mm                       S       Slight
                                  Ys = >20 – 40mm                   M       Moderate
                                  Ys = >40 – 60mm                   H1      High-1
                                  Ys = 60 – 75mm                    H2      High-2
                                  Ys = > 75mm                       E       Extreme
                                  Problem sites                     P       Problem


3.0        SITE DESCRIPTION:

The construction area has a gradient in the order of 8-9%.

Vegetation on the construction area (and nearby surrounds) consists of grasses and scattered trees.

The trees are located in the neighbouring allotment on and adjacent the proposed construction site.

The trees are of a height and proximity that could affect the moisture conditions within the proposed construction site.
Refer to the appendices to the rear of this report for guidance on Trees and Construction.

The existing surface drainage is good and sub-surface drainage is good.




      Australian Soil Investigations                           1                            ASI Ref: 250131(S)

Page 16

4.0        FINDINGS:

The soil profiles encountered are shown on the attached borelog sections.

No water table was encountered during our testing program.

The sandy soils encountered are susceptible to collapse when unconfined. This may effect excavations and result
in additional earthworks and increased concrete volumes. Temporary shoring or Forma-Tube may be required to
retain the sands prior to concreting.

The samples classified on-site were assessed as having negligible plasticity, therefore laboratory testing was
considered unnecessary.

We have assessed the expected differential movement of the soil profiles encountered to be the equivalent of a site
with a Ys of less than 20mm.

Fill, which we have described as uncontrolled was encountered to the following depths

                                       Test Site 1 - 500 mm        Test Site 2 - 400mm

At the time of writing this report we were unable to describe the fill as controlled. This can be revised if documentation
is available indicating that this fill has been compacted and certified in accordance with AS 3798-2007.



The following foundation material will provide a safe bearing capacity (100 kPa) for buildings within the scope of AS
2870-2011.

                FOUNDATION MATERIAL - NATURAL MEDIUM DENSE SILTY SAND

We strongly recommend that any footing design for this allotment be carried out by a suitably qualified
person in accordance with AS2870-2011.

Where site drainage and landscaping does not conform to the specifications of AS 2870-2011 and CSIRO
Information Service Sheet BTF-18 (2003) damage to the building can be expected. A single copy of this
document is issued with the original issue of this report. Please consult your builder or contact this office
to obtain a copy.

NOTE:       The information contained herein has been compiled following our field and laboratory testing,
            accepted engineering theory and discussions with and information supplied by our client, whom is
            noted on the header page of this report. We offer no warranty for the use of this report by other
            parties without prior written consent from this office.
            The report must be read in conjunction with the attached appendices. If you do not have a copy of
            these please contact our office and a copy can be issued to you.




WADE HOLMES – QBCC 1120066
for and on behalf of:
AUSTRALIAN SOIL INVESTIGATIONS – QBCC 15072110



      Australian Soil Investigations                           2                             ASI Ref: 250131(S)

Page 17

APPENDICES
A.   SITE PLAN

B.   BORELOGS

C.   DEFINITIONS

D.   LIMITATIONS

E.   RECOMMENDATIONS
     C.1 - Builders
     C.2 - Owners
     C.3 - Builder/Owner - Trees

F.   DETAIL SHEETS
     D.1 - Plumbing Requirements Class M, H1, H2 & E Sites
     D.2 - Site Drainage recommendations

G.   CSIRO- Home Owners Guide

Page 18

                                                                Revision   Description              Date
                                                                                                    .
                                                                                                    .
                                                                                                    .




                                                                                         BH 2



                                                         8-9%




                                   BH 2




  SITE PLAN
                                             Lot 10
   Site Drainage
                                            RP89506
   Vegetation
                                            506sq.m                        AUSTRALIAN
        BH 2
                                                                     SOIL INVESTIGATIONS
                Borehole location.

                Slope
                                                                 Title        SITE PLAN
                measured as a percentage gradient from
                high ground to low ground.                       Project

DO NOT DIMENSION OFF THIS DIAGRAM.                               Date:                    Drg No.
                                                                                                    Rev.

Page 19

  Australian Soil Investigations              LOG SECTIONS         Ref No. 250131
  Client:         M. Bennett
  Location:       (Lot 10 on RP89506) 19 Attunga Heights, Noosa Heads
  Date:           25/03/2025
                                    (House Site)
Depth         TEST SITE No 1           P    Depth          TEST SITE No 2         P
 100           Fill Silty Sand (SM)                1    100           Fill Silty Sand (SM)             1
 200       Fine to coarse grained dark             1    200       Fine to coarse grained dark          1
 300         grey, roots, moist, loose             1    300         grey, roots, moist, loose          1
 400                                               1    400              Silty Sand (SM)               1
 500             Silty Sand (SM)                   1    500       Fine to coarse grained, grey,        1
 600      Fine to coarse grained, grey,            1    600            roots, moist, loose             1
 700           roots, moist, loose                 1    700                                            1
 800                                               1    800                                            1
 900                                               2    900                                            2
1000                                               2   1000                                            2
1100                                               2   1100             Silty Sand (SM)                3
1200                                               2   1200       Fine to coarse grained, pale         3
1300            Silty Sand (SM)                    2   1300      grey, moist, becoming medium          2
1400      Fine to coarse grained, pale             2   1400                   dense                    3
1500     grey, moist, becoming medium              3   1500                                            3
1600                  dense                        3   1600                                            4
1700                                               4   1700                                            4
1800                                               4   1800                                            5
1900                                               4   1900                                            5
2000                                               4   2000                     End                    5
2100                                               4   2100                                            6
2200                                               5   2200                                            5
2300                                               5   2300                                            6
2400                                               5   2400                                            6
2500                                               6   2500                                            6
2600                                               6   2600                                            7
2700                                               7   2700                                            6
2800                                               7   2800                                            7
2900                                               6   2900                                            7
3000                    End                        7   3000                                            7
3100                                               7   3100
3200                                               7   3200



   Depth = mm below ground level.
   P = blows per 100mm penetration with an approved 9kg penetrometer.
   Notation such as (SP) refers to the soil description to Table A1 AS1726 ‘Guide to the description
   identification and classification of soils’.
   Solid lines represent sharp interface between different soil types. Dotted lines represent
   gradation form one soil type to another.
   Abbreviations used
   UTP - unable to penetrate, Bec. – becoming, N.S.L. – Natural Surface Level
   Med. – medium, MW - Moderately weathered
   EW - extremely weathered, Plast. - Plasticity
   No recovery means unable to extract samples from the base of the bore hole because the soil
   will not bind in the auger head.
   The colour of the soil is often abbreviated, for example Gy = grey Or = orange.

Page 20

C.      DEFINITIONS
Safe Bearing capacity: The soil nominated in this report as a suitable foundation material has an allowable bearing capacity of 100KPa and
is considered safe for the construction of a dwelling that is in accordance with AS2870-2011.
Cohesive Soils:      Clays and silt soils that have inherent cohesive (binding) strength.
Granular Soils:      Gravels and sand soils that have no cohesive strength. Individual particles can flow under certain conditions.
Controlled Fill: Manually placed soil which has been placed and compacted to achieve sufficient bearing capacity to support a structure
according to AS 2870-2011. Fill certified at Level 1 according to AS 3798 and 95% Relative Field Density is considered controlled fill.
Partially Controlled: Manually placed soil which appears to have been compacted under controlled conditions but, at the time of preparing
this report, no compaction certificate suitable for compliance to Level 1 of AS 3798-2007 had been presented.
Uncontrolled Fill: Manually placed soil (overlying the natural soils) which is not adequate to support a normally loaded footing or floor slab
or structural load.
Unexcavatable Rock: Strong material that does not soften in water or collapse under the combination of loading and wetting. Material that
cannot readily be excavated by a backhoe.
Excavatable Rock: A rock-like material including shaly material and strongly cemented sand or gravel which does not shrink or swell with
changes in soil moisture, but is readily excavatable with a conventional backhoe.
Load Bearing Wall: In our design work a load bearing wall is defined as any wall imposing on the footing a service load greater than 10kN/m.
A load bearing wall will normally be supported by a slab thickening or footing in our slab designs.
Natural (Strata): Refers to soil that is neither fill or imported material but one that is in its original undisturbed state and position.
Gravel: Coarse particles, larger than sand size, but less than 60mm in diameter.
Cobbles: Rocks greater than 60mm in diameter but less than 600mm in diameter.
Boulders: Rocks larger than 600mm in diameter.



                                                      SOIL STRENGTH INDICATIONS
             NON-COHESIVE (GRANULAR) SOILS                                                             COHESIVE SOILS
 Loose          A 12mm rod/bar can be easily pushed in by hand               Soft            Can be moulded by light finger pressure.

 Medium         A 12 mm rod/bar can be pushed in 300mm with                  Firm            Can be moulded by strong finger pressure.
 Dense          difficulty
 Dense          A 12mm rode cannot be pushed in by hand.                     Stiff           Cannot be moulded by fingers. Can be indented by
                                                                                             thumb with pressure.
                                                                             Very Stiff      Can be indented only by thumb nail.
N.B.   These indications should be used for guidance only. These indications can vary greatly under Abnormal Moisture Conditions.
Please contact Australian Soil Investigations for on-site clarification of soil strengths.



D.      LIMITATIONS
AS2870-2011:            This report has been completed in accordance with AS2870-2011 the Australian Standard for “Residential Slabs and
Footings” design and construction. The standard provides performance based criteria for its design recommendations. This criteria is not
based upon crack or movement free performance. The code states “It is acknowledged that minor foundation movements occur on nearly all
sites and that it is impracticable to design a footing system that will protect the building from movement under all circumstances”. The code
provides guidance on the assessment of crack sizes in walls and floors and suggests acceptable limits. Should the potential owner not be
satisfied with this criteria we should be notified such that any recommendations can be amended to suit their requirements. However, it should
be noted this could dramatically increase the construction costs.
Field Testing: Our investigation and the results and recommendations contained herein have been compiled following careful consideration
of our clients supplied information and instructions. Any variation to this information may render this report incorrect. Furthermore this report
must not be used by any person other than our client noted at the head of the report.
Client Supplied Information: In writing this report we have considered all the information supplied to us by the client. Should the client or
his agent have omitted to supply us with relevant information our report may be irrelevant and / or inappropriate. We do not accept
responsibility for the consequences in such cases.
Borelogs: The soil profiles reported in our Borelogs Section represent the soil conditions at our test sites and have been located were we
believe best represents the soils within the proposed building envelope. However soil conditions can change dramatically over short distances,
therefore such point type exploration programs may not locate all variations. If site preparations/excavations reveal soil conditions that are
different from those shown in our Borelogs we must be notified immediately. Changes to the site classification and/or footing design may be
necessary.
Site Information: The site information shown on the attached plans such as surface grades and levels are estimations taken during our field
testing and are provided for a rough guide. They must not be used for any design purposes. Site plan dimensions are as measured from the
noted visible site feature during our field testing.
Previous/Future Excavations: The recommendations contained in this report have not considered the effects of any previous, current or
future excavations, mines or slope instability problems that are not highlighted in the clients supplied information or, that was not clearly visible
during our field testing. If such features exist we must be advised so that our design can be adjusted to accommodate them.

 Australian Soil Investigations                                  Appendix Page 2 of 6                                                 Appendices.1

Page 21

Trees: Trees can have a considerable influence over the over the performance of a structures foundation, in particular those founded on
reactive soils (Class S, M, H & E). The trees demand for moisture will change the moisture characteristics of the surrounding soils leading to
localised shrinking and swelling which can exceed the expected soil movement. This can include trees that have been removed prior to
construction. During our Field-testing we have considered trees that existed on or adjacent the site and allowed for them in our
recommendations. We are unable to assess for the potential effects of trees planted after our testing, reference should be made to
“Recommendations for Builders/Owners-Trees” in Appendix D that follows.
Moisture Conditions: The moisture conditions noted within this report are as recorded at the time of our field testing and have been included
in our assessment of the site. Changes to site drainage, the planting of trees or a rising water table can lead to increased levels of moisture
within the soils leading to either an increased classification or design requirements. We must be notified of any increase in moisture conditions.
Also refer to “Recommendations for Builders/Owners – Site Drainage in Appendix D that follows.
Aggressive/Contaminated Soils: This report does not consider the presence of contaminants or sulphates within the tested soils as this is
beyond the scope of this report and our expertise. Engagement of a specialist consultant is advised if this form of assessment is required.
Landslip: This report does not address slope stability issues. A specialist report must be obtained to assess such hazards.
Shrinkage Cracking:           Shrinkage cracking of concrete occurs as the initial moisture in the concrete evaporates from mix causing
shrinkage to occur. The cracking as a result of this shrinkage is not a sign of structural failure and is to be expected in most concrete elements
poured on-site. AS2870-2011 states “Shrinkage cracking can be expected in concrete floors”.



E         RECOMMENDATIONS
E.1     Recommendations for Builders and Foundation Designers
Codes of Practice: All construction work associated with this report must be undertaken in accordance with the BCA “part 3.1 – Site
Preparation” and “part 3.2 – Footings & Slabs” and AS2870-2011 “Residential Slabs and Footings”.
Underground Services/Plumbing: Where structures are built over filled, soft or loose soils, services will need to be supported so that
potential movement within the soils does not cause them damage or cause incorrect alignment which could cause leakage. Such measures
can include but are not limited to the provision of expansion joints, sleeved or foam lagged pipe penetrations throughout the structure or
treatment of the soils prior to construction. The attached illustrations detail minimum requirements.
Arrange plumbing fixtures so that the slab and beam penetrations are kept to a minimum and where necessary sleeved to allow for movement
with 40mm thick closed cell polythene or similar material. Where the penetration is within 150mm of the base of a beam or footing, the depth
of this footing element should be deepened by approximately twice the diameter of the penetration. All plumbing and drainage must comply
with the requirements of the National Plumbing and Drainage Code AS3500.
For Class H & E sites, AS2870 - 2011 requires that plumbing pipes servicing dwellings in class H & E sites be fitted with sleeved expansion
joints, rotational swivel joints and foam lagged penetrations.
Refer to the attached detail sheet “Plumbing Requirements Class M, H and E sites.
Site Drainage - Class A Sites: The ground surrounding the dwelling and the building site must be graded and drained so that stormwater is
shed away from the house area in all directions during and after construction. Particular attention should be given to all drainage so stormwater
is not introduced to the foundation soils leading to potential scour. Roof water must be diverted away from the building prior to and after the
roof is installed. Correct drainage is an essential part of our recommendations. If the site is not prepared correctly, excessive foundation
movements may occur leading to damage within the supported structure.
Site Drainage - Class S, M, H & E Sites: The ground surrounding the dwelling and the building site must be graded and drained so that
stormwater is shed away from the house area in all directions, during and after construction. A minimum grade of 1 : 20 (vertical : horizontal)
for 1.5m must be provided. Hard landscaping such as terrace slabs adjacent the dwelling can assist in this. Roof water must be diverted
away from the building site prior to and after the roof is installed. Where building delays occur, temporary downpipes may be necessary.
Constant maintenance of roof drainage is essential. If a rainwater tank (or similar) is to be sited within 6 meters of a structural footing, we
should be consulted for further advice. External water taps, air conditioner overflows, tank and hot water cylinder overflows should be over
grated pits connected to the drainage system. The ground surrounding the building must be graded and drained so water is shed away from
the house in all directions.
Particular care should be taken with drainage, plumbing and electrical trenches so that they do not introduce moisture into the soils supporting
the foundations or destabilise the footings by undermining them. The base of any trenches under the floor or within 1.5 meters of the building
should be sloped away from the house and should be backfilled with compacted clay plug.
Correct drainage is an essential part of our recommendations and is documented in the CSIRO handout BTF-18 attached to the clients copy
of this report. (Additional copies available upon request.) If the site is not prepared correctly, excessive soil moisture may occur in some
areas, which can lead to excessive foundation movements possibly damaging the supported structure.
Inspections: We require 24 hours notice if you require engineers site inspections. Inspections can be booked between 8.30am and 4.30pm
Monday to Friday by telephoning 07 5455 5604.
Silt Retention: The builder is responsible for ensuring appropriate silt retention measures are in placed and maintained throughout
construction.
Site Classification: The site classification is calculated in accordance with the “AS2870-2011 - Residential Slabs and Footings-Construction”
and relates to the estimation of Ys, “The characteristic surface movement” within reactive soil profiles. The limits used for this classification
are as follows:
                                     Predicted Surface Movement                   Classification
                                     Ys = <=20mm                                  S          Slight
                                     Ys = >20 – 40mm                              M          Moderate
                                     Ys = >40 – 60mm                              H1         High-1
                                     Ys = 60 – 75mm                               H2       High-2
                                     Ys = > 75mm                                  E          Extreme
                                     Problem sites                                P          Problem

 Australian Soil Investigations                                Appendix Page 3 of 6                                               Appendices.1

Page 22

E.2     Recommendations for Owners
Foundation Maintenance and Owners Responsibilities: The soils surrounding and under the foundations must be protected from scour
or washout from stormwater by ensuring adequate drainage as noted above.
Localised concentrations of moisture such as overflows from hot water cylinders or air conditioners can lead to excessive localised foundation
movements and must also be adequately drained away from the foundations as noted above.
In all types of soil conditions, if an automatic watering system irrigates within 2.5 meters of a foundations, instability problems and excessive
foundation movements are likely to occur. Also site drainage as discussed above must be maintained.
Ongoing foundation maintenance is documented in the CSIRO handout BTF-18, attached to the client’s copy of this report. (Additional copies
available upon request.)
Refer to the attached detail sheet “General Requirements for Site Drainage”
Additional Requirements - Class A & S Sites: Trees and dense shrubs must be kept well away from the building foundations. Refer to the
following section “Recommendations – Builders/Owners – Trees”. In all types of soil conditions, if an automatic watering system irrigates within
2.5 meters of a footing, instability problems may occur. Water should not be allowed to pond on the ground near the building. Finished
surface grades around the building should also ensure scour of soils cannot occur. Additional field gullies and drainage might be required.
In all instances the ground should be sloped away from the foundations at a grade of no less than 1 in 20 (vertical to horizontal) for at least
1.5m.
Additional Requirements - Class M, H & E Sites: Trees and dense shrubs must be kept well away from the building foundations. Refer to
the following section “Recommendations – Builders/Owners – Trees”.
The soil near the building should be protected against the increased moisture that occurs in gardens or permeable landscaping built adjacent
the foundations. Automatic irrigation systems must not be used adjacent structural foundations. If required, these forms of landscaping must
be constructed over impermeable membranes that drain the excessive moisture away from the foundations into correctly installed field gullies
and drains.
We strongly recommend the construction of hard landscaped paths or terrace slabs adjacent building foundations for at least a distance of
1.5m to protect the foundations from excessive moisture.
E.3     Recommendations – Builders/Owners - Trees
Trees and landscaped gardens can have a dramatic influence over the moisture content of the soils they are grown in. This can lead to
increased soil movement through shrinking and swelling. Where these trees or gardens are within close proximity of structural foundations
the soil movements can affect the structural integrity of the foundations.
For Class M, H and E sites the following recommendations for the minimum distance between trees and footings should be followed:-

                                          Site Class                      Offset to Tree
                                           Class M            :              0.75 x h
                                           Class H            :              1.0 x h
                                           Class E            :              1.5 x h
Where ‘h’ is the mature height of the tree, further refinement of this recommendation can be pursued where tree species can be considered.
Where a row or group of trees exists the above recommendation should be doubled.
In some instances the installation of root barriers can lessen the effect of trees on foundation performance. Please contact Australian Soil
Investigations for options.
The following table provides some guidance on mature tree heights:-
        APPROXIMATE TREE HEIGHTS
 10 to 20m Height – Acacias, Ash, Athel Tree, Candlebark, Manna Gum, Pepper Tree, Willows, Yate, Yellow Gum
 20 to 30m Height – But-But, Cedars, English Oak, Lemon Gum, Palms, Planes, Sheoaks, Silky Oak, Spotted Gum, Casuarina
 30 to 60m Height – Blue Gum, Cypress, English Elm, Figs, Karri, Pines, River Gum, Sugar Gum


The removal of trees from the proposed construction can also greatly affect the moisture conditions of the soil. We recommend allowing the
soil time to reach moisture equilibrium prior to construction commencing. Please contact our office for further guidance on this matter.




 Australian Soil Investigations                                   Appendix Page 4 of 6                                           Appendices.1

Page 23

F        DETAIL SHEETS
F.1      Plumbing Requirements Class M, H1, H2 & E Sites




 Australian Soil Investigations                 Appendix Page 5 of 6   Appendices.1

Page 24

F.2      Site Drainage recommendations




 Australian Soil Investigations          Appendix Page 6 of 6   Appendices.1

Page 25

BUILDING ‘Techotocy|nesounces

FOUNDATION MAINTENANCE AND
FOOTING PERFORMANCE

Understanding and preventing soil-related building movement

This Building Technology Resource is designed to identify causes of soil-related
building movement, and to suggest methods of prevention of resultant cracking.

Buildings can and often do move. This movement can be up,
down, lateral or rotational. The fundamental cause of movement
in buildings can usually be related to one or more problems in the
foundation soil. It is important for the home owner to identify the
soil type in order to ascertain the measures that should be put in
place in order to ensure that problems in the foundation soil can
be prevented, thus protecting against building movement.

SOIL TYPES

The types of soils usually present under the topsoil in land zoned
for residential buildings can be split into two approximate groups —
granular and clay. Quite often, foundation soil is a mixture of both
types. The general problems associated with soils having granular
content are usually caused by erosion. Clay soils are subject to
saturation and swell/shrink problems.

Classifications for a given area can generally be obtained by
application to the local authority, but these are sometimes unreliable
andif there is doubt, a geotechnical report should be commissioned.
As most buildings suffering movement problems are founded on
clay soils, there is an emphasis on classification of soils according to
the amount of swell and shrinkage they experience with variations
of water content. Table 1 below is a reproduction of Table 2.1 from
Australian Standard AS 2870-2011, Residential slabs and footings.

CAUSES OF MOVEMENT

SETTLEMENT DUE TO CONSTRUCTION
There are two types of settlement that occur as a result of construction:

> Immediate settlement occurs when a building is first placed on
its foundation soil, as a result of compaction of the soil under the
weight of the structure. The cohesive quality of clay soil mitigates
against this, but granular (particularly sandy) soil is susceptible.

> Consolidation settlement is a feature of clay soil and may take
place because of the expulsion of moisture from the soil or
because of the soil’s lack of resistance to local compressive or
shear stresses. This will usually take place during the first few
months after construction but has been known to take many
years in exceptional cases.
These problems may be the province of the builder and should be
taken into consideration as part of the preparation of the site for
construction.

EROSION

Allsoils are prone to erosion, but sandy soil is particularly susceptible
to being washed away. Even clay with a sand component of say
10% or more can suffer from erosion.

SATURATION

This is particularly a problem in clay soils. Saturation creates a bog-
like suspension of the soil that causes it to lose virtually all of its
bearing capacity. To a lesser degree, sand is affected by saturation
because saturated sand may undergo a reduction in volume,

particularly imported sand fill for bedding and blinding layers.
However, this usually occurs as immediate settlement and should
normally be the province of the builder.

SEASONAL SWELLING AND SHRINKAGE OF SOIL

All clays react to the presence of water by slowly absorbing it,
making the soil increase in volume (see table below, from AS 2870).
The degree of increase varies considerably between different clays,
as does the degree of decrease during the subsequent drying out
caused by fair weather periods. Because of the low absorption and
expulsion rate, this phenomenon will not usually be noticeable
unless there are prolonged rainy or dry periods, usually of weeks
or months, depending on the land and soil characteristics.

The swelling of soil creates an upward force on the footings of the
building, and shrinkage creates subsidence that takes away the
support needed by the footing to retain equilibrium.

SHEAR FAILURE
This phenomenon occurs when the foundation soil does not have
sufficient strength to support the weight of the footing. There are
two major post-construction causes:

» Significant load increase.

» Reduction of lateral support of the soil under the footing due to
erosion or excavation.

In clay soil, shear failure can be caused by saturation of the soil
adjacent to or under the footing.

TREE ROOT GROWTH

Trees and shrubs that are allowed to grow in the vicinity of footings
can cause foundation soil movement in two ways:

» Roots that grow under footings may increase in cross-sectional
size, exerting upward pressure on footings.

TABLE 1. GENERAL DEFINITIONS OF SITE CLASSES.

Class Foundation

A Most sand and rock sites with little or no ground movement from
moisture changes

5 Slightly reactive clay sites, which may experience only slight
ground movement from moisture changes

M Moderately reactive clay or silt sites, which may experience
moderate ground movement from moisture changes

1 Highly reactive clay sites, which may experience high ground
Movement from moisture changes

42 Highly reactive clay sites, which may experience very high ground
Movement from moisture changes

E Extremely reactive sites, which may experience extreme ground

Movement from moisture changes

Source: Reproduced with the permission of Standards Australia Limited © 2011. Copyright
in AS 2870-2011 Residential slabs and footings vests in Standards Australia Limited.

© CSIRO 2021

Page 26

 

 

 

 

Wall cracking
due to uneven
footing settlement

 

FIGURE 1 Trees can cause shrinkage and damage.

» Roots in the vicinity of footings will absorb much of the moisture
in the foundation soil, causing shrinkage or subsidence.

UNEVENNESS OF MOVEMENT

The types of ground movement described above usually occur
unevenly throughout the building’s foundation soil. Settlement
due to construction tends to be uneven because of:

> Differing compaction of foundation soil prior to construction.

> Differing moisture content of foundation soil priorto construction.
Movement due to non-construction causes is usually more uneven
still. Erosion can undermine a footing that traverses the flow or can
create the conditions for shear failure by eroding soil adjacent to a
footing that runs in the same direction as the flow.

Saturation of clay foundation soil may occur where subfloor walls
create a dam that makes water pond. It can also occur wherever
there is a source of water near footings in clay soil. This leads to a
severe reduction in the strength of the soil which may create local
shear failure.

Seasonal swelling and shrinkage of clay soil affects the perimeter
of the building first, then gradually spreads to the interior through
absorption. The swelling process will usually begin at the uphill
extreme of the building, or on the weather side where the land is
flat. Shrinkage usually begins on the side of the building where the
sun’s heat is greatest.

EFFECTS OF UNEVEN SOIL MOVEMENT ON STRUCTURES

EROSION AND SATURATION

Erosion removes the support from under footings, tending to
create subsidence of the part of the structure under which it occurs.
Brickwork walls will resist the stress created by this removal of support
by bridging the gap or cantilevering until the bricks or the mortar
bedding fail. Older masonry has little resistance. Evidence of failure
varies according to circumstances and symptoms may include:

> Step cracking in the mortar beds in the body of the wall or
above/below openings such as doors or windows.

» Vertical cracking in the bricks (usually but not necessarily in line
with the vertical beds or perpends).
Isolated piers affected by erosion or saturation of foundations will
eventually lose contact with the bearers they support and may
tilt or fall over. The floors that have lost this support will become
bouncy, sometimes rattling ornaments etc.

SEASONAL SWELLING/SHRINKAGE IN CLAY

Swelling foundation soil due to rainy periods first lifts the most
exposed extremities of the footing system, then the remainder
of the perimeter footings while gradually permeating inside the
building footprint to lift internal footings. This swelling first tends
to create a dish effect, because the external footings are pushed
higher than the internal ones.

The first noticeable symptom may be that the floor appears slightly
dished. This is often accompanied by some doors binding on the
floor or the door head, together with some cracking of cornice
mitres. In buildings with timber flooring supported by bearers

and joists, the floor can be bouncy. Externally there may be visible
dishing of the hip or ridge lines.

As the moisture absorption process completes its journey to the
innermost areas of the building, the internal footings will rise. If the
spread of moisture is roughly even, it may be that the symptoms
will temporarily disappear, but it is more likely that swelling will
be uneven, creating a difference rather than a disappearance in
symptoms. In buildings with timber flooring supported by bearers
and joists, the isolated piers will rise more easily than the strip
footings or piers under walls, creating noticeable doming of flooring.

As the weather pattern changes and the soil begins to dry out, the
external footings will be first affected, beginning with the locations
where the sun's effect is strongest. This has the effect of lowering
the external footings. The doming is accentuated, and cracking
reduces or disappears where it occurred because of dishing, but
other cracks open up. The roof lines may become convex.

Doming and dishing are also affected by weather in other ways. In
areas where warm, wet summers and cooler dry winters prevail,
water migration tends to be toward the interior and doming will
be accentuated, whereas where summers are dry, and winters are
cold and wet, migration tends to be toward the exterior and the
underlying propensity is toward dishing.

MOVEMENT CAUSED BY TREE ROOTS

In general, growing roots will exert an upward pressure on footings,
whereas soil subject to drying because of tree or shrub roots will
tend to remove support from under footings by inducing shrinkage.

COMPLICATIONS CAUSED BY THE STRUCTURE ITSELF

Most forces that the soil causes to be exerted on structures are
vertical — i.e. either up or down. However, because these forces
are seldom spread evenly around the footings, and because the
building resists uneven movement because of its rigidity, forces
are exerted from one part of the building to another. The net result
of all these forces is usually rotational. This resultant force often
complicates the diagnosis because the visible symptoms do not
simply reflect the original cause. A common symptom is binding
of doors on the vertical member of the frame.

EFFECTS ON FULL MASONRY STRUCTURES

Brickwork will resist cracking where it can. It will attempt to span
areas that lose support because of subsided foundations or raised
points. It is therefore usual to see cracking at weak points, such as
openings for windows or doors.

In the event of construction settlement, cracking will usually
remain unchanged after the process of settlement has ceased.

With local shear or erosion, cracking will usually continue to develop
until the original cause has been remedied, or until the subsidence
has completely neutralised the affected portion of footing and the
structure has stabilised on other footings that remain effective.

In the case of swell/shrink effects, the brickwork will in some cases
return to its original position after completion of a cycle, however it
is more likely that the rotational effect will not be exactly reversed,
and it is also usual that brickwork will settle in its new position and
will resist the forces trying to return it to its original position. This
means that in a case where swelling takes place after construction
and cracking occurs, the cracking is likely to at least partly remain
after the shrink segment of the cycle is complete. Thus, each time
the cycle is repeated, the likelihood is that the cracking will become
wider until the sections of brickwork become virtually independent.

With repeated cycles, once the cracking is established, if there is
no other complication, it is normal for the incidence of cracking to
stabilise, as the building has the articulation it needs to cope with the
problem. This is by no means always the case, however, and monitoring
of cracks in walls and floors should always be treated seriously.

Upheaval caused by growth of tree roots under footings is not a
simple vertical shear stress. There is a tendency for the root to also

© CSIRO 2021

Page 27

exert lateral forces that attempt to separate sections of brickwork
after initial cracking has occurred.

The normal structural arrangement is that the inner leaf of
brickworkin the external walls and at least some of the internal walls
(depending on the roof type) comprise the load-bearing structure
on which any upper floors, ceilings and the roof are supported. In
these cases, it is internally visible cracking that should be the main
focus of attention, however there are a few examples of dwellings
whose external leaf of masonry plays some supporting role, so
this should be checked if there is any doubt. In any case, externally
visible cracking is important as a guide to stresses on the structure
generally, and it should also be remembered that the external
walls must be capable of supporting themselves.

EFFECTS ON FRAMED STRUCTURES

Timber or steel framed buildings are less likely to exhibit cracking
due to swell/shrink than masonry buildings because of their
flexibility. Also, the doming/dishing effects tend to be lower
because of the lighter weight of walls. The main risks to framed
buildings are encountered because of the isolated pier footings
used under walls. Where erosion or saturation causes a footing to
fall away, this can double the span which a wall must bridge. This
additional stress can create cracking in wall linings, particularly
where there is a weak point in the structure caused by a door or
window opening. It is, however, unlikely that framed structures will
be so stressed as to suffer serious damage without first exhibiting
some or all of the above symptoms for a considerable period.
The same warning period should apply in the case of upheaval.
It should be noted, however, that where framed buildings are
supported by strip footings there is only one leaf of brickwork and
therefore the externally visible walls are the supporting structure
for the building. In this case, the subfloor masonry walls can be
expected to behave as full brickwork walls.

EFFECTS ON BRICK VENEER STRUCTURES

Because the load-bearing structure of a brick veneer building
is the frame that makes up the interior leaf of the external walls
plus perhaps the internal walls, depending on the type of roof,
the building can be expected to behave as a framed structure,
except that the external masonry will behave in a similar way to
the external leaf of a full masonry structure.

WATER SERVICE AND DRAINAGE

Where a water service pipe, a sewer or stormwater drainage pipe is
in the vicinity of a building, a water leak can cause erosion, swelling
or saturation of susceptible soil. Even a minuscule leak can be
enough to saturate a clay foundation. A leaking tap near a building
can have the same effect. In addition, trenches containing pipes
can become watercourses even though backfilled, particularly
where broken rubble is used as fill. Water that runs along these
trenches can be responsible for serious erosion, interstrata
seepage into subfloor areas and saturation.

Pipe leakage and trench water flows also encourage tree and
shrub roots to the source of water, complicating and exacerbating
the problem. Poor roof plumbing can result in large volumes of
rainwater being concentrated in a small area of soil:

> Incorrect falls in roof guttering may result in overflows, as may
gutters blocked with leaves etc.

» Corroded guttering or downpipes can spill water to ground.

» Downpipes not positively connected to a proper stormwater
collection system will direct a concentration of water to soil
that is directly adjacent to footings, sometimes causing large-
scale problems such as erosion, saturation and migration of
water under the building.

SERIOUSNESS OF CRACKING

In general, most cracking found in masonry walls is a cosmetic
nuisance only and can be kept in repair or even ignored. Table 2
below is a reproduction of Table C1 of AS 2870-2011.

AS 2870-2011 also publishes figures relating to cracking in
concrete floors, however because wall cracking will usually reach
the critical point significantly earlier than cracking in slabs, this
table is not reproduced here.

PREVENTION AND CURE
PLUMBING

Where building movement is caused by water service, roof
plumbing, sewer or stormwater failure, the remedy is to repair the
problem. It is prudent, however, to consider also rerouting pipes
away from the building where possible and relocating taps to
positions where any leakage will not direct water to the building
vicinity. Even where gully traps are present, there is sometimes
sufficient spill to create erosion or saturation, particularly in
modern installations using smaller diameter PVC fixtures. Indeed,
some gully traps are not situated directly under the taps that are
installed to charge them, with the result that water from the tap
may enter the backfilled trench that houses the sewer piping. If
the trench has been poorly backfilled, the water will either pond
or flow along the bottom of the trench. As these trenches usually
run alongside the footings and can be at a similar depth, it is not
hard to see how any water that is thus directed into a trench can
easily affect the foundation's ability to support footings or even
gain entry to the subfloor area.

GROUND DRAINAGE

In all soils there is the capacity for water to travel on the surface
and below it. Surface water flows can be established by inspection
during and after heavy or prolonged rain. If necessary, a grated
drain system connected to the stormwater collection system is
usually an easy solution.

It is, however, sometimes necessary when attempting to prevent
water migration that testing be carried out to establish watertable
height and subsoil water flows. This subject may be regarded as an
area for an expert consultant.

PROTECTION OF THE BUILDING PERIMETER

It is essential to remember that the soil that affects footings extends
well beyond the actual building line. Watering of garden plants,
shrubs and trees causes some of the most serious water problems.

For this reason, particularly where problems exist or are likely to
occur, it is recommended that an apron of paving be installed
around as much of the building perimeter as necessary. This
paving should extend outwards a minimum of 900 mm (more in
highly reactive soil) and should have a minimum fall away from
the building of 1:60. The finished paving should be no less than
100 mm below brick vent bases.

It is prudent to relocate drainage pipes away from this paving,
if possible, to avoid complications from future leakage. If this is
not practical, earthenware pipes should be replaced by PVC and
backfilling should be of the same soil type as the surrounding soil
and compacted to the same density.

Except in areas where freezing of water is an issue, it is wise to
remove taps in the building area and relocate them well away
from the building — preferably not uphill.

It may be desirable to install a grated drain at the outside edge of
the paving on the uphill side of the building. If subsoil drainage is
needed this can be installed under the surface drain.

CONDENSATION

In buildings with a subfloor void, such as where bearers and joists
support flooring, insufficient ventilation creates ideal conditions
for condensation, particularly where there is little clearance
between the floor and the ground. Condensation adds to the
moisture already present in the subfloor and significantly slows
the process of drying out. Installation of an adequate subfloor
ventilation system, either natural or mechanical, is desirable.

© CSIRO 2021

Page 28

TABLE 2. CLASSIFICATION OF DAMAGE WITH REFERENCE TO WALLS.

Description of typical damage and required repair

Hairline cracks
Fine cracks which do not need repair
Cracks noticeable but easily filled. Doors and windows stick slightly.

Cracks can be repaired and possibly a small amount of wall will need to be replaced. Doors and

windows stick. Service pipes can fracture. Weathertightness often impaired.

Extensive repair work involving breaking-out and replacing sections of walls, especially over doors
and windows. Window and door frames distort. Walls lean or bulge noticeably, some loss of

bearing in beams. Service pipes disrupted.

Approximate crack width limit Damage category
<0.1mm 0—Negligible
<imm 1—-Very Slight
<5mm 2-Slight

5-15 mm (or a number of cracks 3 mm 3— Moderate

or more in one group)

15-25 mm but also depends onnumber 4 - Severe

of cracks

Source: Reproduced with the permission of Standards Australia Limited © 2011. Copyright in AS 2870-2011 Residential slabs and footings vests in Standards Australia Limited.

Warning: Although this Building Technology Resource deals with
cracking in buildings, it should be said that subfloor moisture can
result in the development of other problems, notably:

>» Water that is transmitted into masonry, metal or timber building
elements causes damage and/or decay to those elements.

» High subfloor humidity and moisture content create an ideal
environment for various pests, including termites and spiders,
and mould.

> Where high moisture levels are transmitted to the flooring and
walls, an increase in the dust mite count can ensue within the
living areas. Dust mites, as well as dampness in general, can
be a health hazard to inhabitants, particularly those who are
abnormally susceptible to respiratory ailments.

THE GARDEN

The ideal vegetation layout is to have lawn or plants that require
only light watering immediately adjacent to the drainage or paving
edge, then more demanding plants, shrubs and trees spread out in
that order.

Overwatering due to misuse of automatic watering systems is a
common cause of saturation and water migration under footings.
If it is necessary to use these systems, it is important to remove
garden beds to a completely safe distance from buildings.

EXISTING TREES

Where a tree is causing a problem of soil drying or there is the
existence or threat of upheaval of footings, if the offending roots
are subsidiary and their removal will not significantly damage
the tree, they should be severed and a concrete or metal barrier
placed vertically in the soil to prevent future root growth in the
direction of the building. If it is not possible to remove the relevant
roots without damage to the tree, an application to remove the
tree should be made to the local authority. A prudent plan is to
transplant likely offenders before they become a problem.

INFORMATION ON TREES, PLANTS AND SHRUBS

State departments overseeing agriculture can give information
regarding root patterns, volume of water needed and safe distance
from buildings of most species. Botanic gardens are also sources
of information.

Garden bed covered
with mulch

Tree height selected for
nce from house

Drained pathway

© Medium
Q height
oO

Shrubs oo

Carport Path Driveway

 

FIGURE 2 Gardens for a reactive site.

EXCAVATION

Excavation around footings must be properly engineered. Soil
supporting footings can only be safely excavated at an angle
that allows the soil under the footing to remain stable. This angle
is called the angle of repose (or friction) and varies significantly
between soil types and conditions. Removal of soil within the
angle of repose will cause subsidence.

REMEDIATION

Where erosion has occurred that has washed away soil adjacent
to footings, soil of the same classification should be introduced
and compacted to the same density. Where footings have been
undermined, augmentation or other specialist work may be
required. Remediation of footings and foundations is generally the
realm of a specialist consultant.

Where isolated footings rise and fall because of swell/shrink effect,
the home owner may be tempted to alleviate floor bounce by filling
the gap that has appeared between the bearer and the pier with
blocking. The danger here is that when the next swell segment of
the cycle occurs, the extra blocking will push the floor up into an
accentuated dome and may also cause local shear failure in the
soil. If it is necessary to use blocking, it should be by a pair of fine
wedges and monitoring should be carried out fortnightly.

@ CSIROPUBLISHING

1300 788 000 | +61 3 9545 8400 | [email protected] | www.publish.csiro.au
For information about CSIRO testing services visit www.csiro.au/en/work-with-us/services
ISBN 9781486312962 (print)/9781486312979 (digital) © CSIRO 2021
(replaces Building Technology File 18, 18-2011 and Information Sheet 10/91)
Unauthorised copying of this material is prohibited.

IMPORTANT DISCLAIMER: This information is prepared for Australia and general in nature. It may be incomplete or inapplicable in some cases.
Laws and regulations may vary in different places. Seek specialist advice for your particular circumstances.
To the extent permitted by law, CSIRO excludes all liability to any person for any loss, damage, cost or other consequence that may result from using this information.

© CSIRO 2021

Page 29

  
 
 
 

 

 

 

 

 

 

  

 

 

 

   

ATTUNGA

North Surveys Pty Ltd ACN 010 803 291

(trading as NorthGroup Consulting) hereby
certify the contours shown on this plan represent
Natural Ground Level as determined on site.

D

Director

 

24/3/LOL5

Date

Scale 1:200 Lengths are in Metres.

HEIGHTS (

 

cp cP
BUP104992 BUPE8S7
0°03'00" 20.105
r2., : :

©
x

g ;

5 s

N §

aubeeas 5 a 1”
8 & RPe9506
9 XN
—_————_— © N

. RP89506

Qe,
Pe,
<o 0'03'00" 20.105 a,
we \ Ys,
ee,
Ss
BENCH MARK
RL 63.907
©

 

 

 

 

 

 

0 | 20/03/25] Original Issue
No| Date | Revision

Seat 1:200

V Datum: AHD | Contourint. 0.2m
V Origin: CORS

H Datum: Cadastral | H Origin: RP89506
Local Authority: Sunshine Coast RC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Surveyed: BW Date: 19/03/25

Drawn: BW Date: 20/03/25

File Ref: 202068 003 | FB: GsI
SHEET 1 OF 1

‘This drawing was generated using AutoCAD Software other formats available on request.

 

 

10 0 5 10 15

 

Qi Pfiloraoaup Corrisulturig

4 Title/Project: Natural Ground Level Survey
19 Attunga Heights, Noosa
Client: Beach Designs

 

 

Creating exceptional value in delivering Surveying, Scanning & Town Planning Solutions

>r'202068 003 NGL* 0

Page 30

                                                                                                                       190                            5820                             190       2200       190                             6120                         90 1110 190                                  4046                             2000

                                                           3000                                                                                       6200                                       2200                                             7700




                                                                                                                                                                                                                                                                                                                                                                                                                                                                     590
   2000




                                                                                                                                                                                                                                                                                                    6000mm setback




                                                                                                                                                                                                                                                                                                                     4500mm setback
                                                                                                                                                                                               BALUSTRADE
           190




                                                                                                                                                                                                                                                                                                                                                                                                                                                                     3315
                                                                                                                                                      TV




                                                                                                                                             living                                                                                                                                                                  pool

                                                                                                                                                                                                                                                                                                                                                                                                 EXISTING TREE

                                                                                                                                                                                                                                            alfresco




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                3580
                                                                                                                                                                                                                                                                                                                                                                                                                                                                     3600
                                                                                                               BALUSTRADE




                                                                                                                                                                                                                                                                                                                                                                                                                                                         4200
           9015




                                                                                                                                                                                                                                                                                                                                                                                                                                                                     190600
                                                                                                                                                                                                                                                                                                                                                                                                                                                         1000 190



                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         190
                                                                                                                                                                                                                                                                                                                                                                                                                                    Attunga Heights
                                                                                                                                                    dining




                                                                                                                                                                                                                                                                                                                                                                                                                                                                     1910
                   190




                                                                                                                                                                                                                                                entry
                                                                                                               PLANTER




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         2910
   15805




                                                                                                                                                                                                                                                                                                                                                                                                                                                         910
                   1910




                                                                                                                                                                                                                                                                                                                                                                                                                                                         190 1000

                                                                                                                                                                                                                                                                                                                                                                                                                                                                     190 1200 190 1000
           190

                   190




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         190
                                                                                                                                                                                   F
                                                                                                                                                                                                                                                   lift         study




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         1800

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                9720
                                                                                                                                                                                                                                                                                                                                                                                                                                                         2330
                                                                                                                                                                                                pdr
           2930

                   2930




                                                                                                                                               kitchen




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         190
                                                                                                                                                                                                                                                                    ROBE




                                                                                                                                                                                                                                                                                                                                                                                                                                                         90
                                                                                                                                                                                               ROBE
           90

                   90 900 90




                                                                                                                                                                                                                                                                                                                                                                                                                                                                     4230
                                                                                                                                                                                                                                                                                      WINDOW SEAT
                                                                                                                                                                                                                                                                                                                                                                                              EXISTING TREES




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         3630
                                                                                                                                   butlers




                                                                                                                                                                                                                                                                                                                                                                                                                                                         3200
                                                                                                                                                                                                                                     bed 2
                                                            1500mm setback

                                                                             2000mm setback

                                                                                              2500mm setback
           3200




                                                                                                                                                      bed 3                                                                                                 bed 1
                                                                                                                                                                                                                  ROBE




                                                                                                                                                                                                 bthrm
                   2210




                                                                                                                                                                                   ROBE




                                                                                                                                                                                                                                  WINDOW SEAT




                                                                                                                                                                                                                                                                                                                                                                                                                                                         600190

                                                                                                                                                                                                                                                                                                                                                                                                                                                                     190

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         190
                                                                                                                                                       WINDOW SEAT
           190

                   190




                                                                                                                            2500mm setback

                                                                                                                            2000mm setback




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                2900
                                                                                                                                                                                                                                                                                                                                        driveway
   2300




                                                                                                                            1500mm setback




                                                                                                                       190 900                             4920                                1500                      3640               190    1600   190        2510                           100                                                                               total floor area = 180m²
                                                                                                                                      90                                                  90         90                                                                                      90
                                                                                                                       190           1920                    3200              600               2440          600                   3000                       3600                                100                                                                               site cover = 206m²
                                                                                                                                               90                                 90                         90                                    90                                        90
                                                           3000                                                                                                   8620                                                                             7480                                                                                6046


                                                                                        Plan
                                                                                        Ground Level                                                                 1 : 100

                                                                                                                                                                                                                                                                                                                                                        No.                      Description                                         Date
                                                                                                                                                                         Project                                         Client                                    Drawing                                                            Drawn by      A              Draft Issue A                                                 17/03/2025                         Project number                           Scale at A3
                                                                                                                                                                         19 Attunga Heights                              Bennett Residence                         GROUND LVL -                                                       DRH           B              Concept Issue B                                               20/03/2025
                                                   dennishillarchitect                                                                                                                                                                                             FLOORPLAN
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         065                    1 : 100

                                            mobile: 0438 20 55 66 | [email protected]
                                                         www.dennishillarchitect.com                                                                                                                                                                                                                                                                                                                                                                                CONCEPT.06
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.                      20/03/2025 8:00:23 PM

Page 31

                                                                                                                                                                                                                                                                                                                        6000mm setback




                                                                                                                                                                                                                                                                                                                                                    4500mm setback
                                                                                                                                                                                                                                        master bed




                                                                                                                                                                                                                                                                                             ensuite
                                                                                                                                                            skylight




                                                                                                                                                           plunge
                                                                                                                                                            pool


                                                                                                                                                                                                                                                                    lift




                                                                                                                                                                                                                                                                                               WIR
                                                                                                                                                                           terrace
                                                                                      1500mm setback

                                                                                                       2000mm setback

                                                                                                                         2500mm setback




                                                                                                                                                                                                                        retreat
                                                                                                                                                                                                                      FR      BAR                      TV

                                                                                                                                          2500mm setback

                                                                                                                                          2000mm setback

                                                                                                                                          1500mm setback




                                                                                                                                                                                                                                                                                                                                                total floor area = 102m²

                                                                                                                        Plan
                                                                                                                        Upper Level                                    1 : 100




                                                                                                                                                                                                                                                                                                                                                                         No.                 Description                             Date
                                                                                                                                                             Project                                 Client                                                        Drawing                                                               Drawn by                    A         Draft Issue A                                     17/03/2025                  Project number               Scale at A3
                                                                                                                                                             19 Attunga Heights                      Bennett Residence                                             UPPER LVL -                                                           DRH                         B         Concept Issue B                                   20/03/2025
                                                   dennishillarchitect                                                                                                                                                                                             FLOORPLAN
                                                                                                                                                                                                                                                                                                                                                                                                                                                                      065                    1 : 100

                                            mobile: 0438 20 55 66 | [email protected]
                                                         www.dennishillarchitect.com                                                                                                                                                                                                                                                                                                                                                                          CONCEPT.07
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.   20/03/2025 8:00:28 PM

Page 32

ROOF DRAINAGE


NOTES:

All work to conform with Part MP 4.2 of the                                                                                                                                                                                                                               600          1500                                                               7000
Queensland Development Code (QDC)
(Water Saving Targets).




                                                                                                                                                                                                                                                                                                                                                                                              6000mm setback




                                                                                                                                                                                                                                                                                                                                                                                                                 4500mm setback
Roof stormwater is to discharge to local
government requirements and approval.
Tank/s overflow and downpipes not
connected to rainwater tank/s to discharge




                                                                                                                                                                                                                                                          600




                                                                                                                                                                                                                                                                                                                                                                                                                                  600
to interallotment drainage system/ to
nominated discharge points via bubbler
system/ to discharge to street channel system.


Based on assumed 5 minute rainfall intensity -
258mm/h 20 years recurrence interval.




                                                                                                                                                                                                                                                                                                     line of upper level walls under
Gutters & downpipes shall be in accordance




                                                                                                                                                                                                                                                          5200
with AS/NZS3500.5 domestic & Part 3.5.2, Vol 2
of the NCC.

All downpipes to be 90mm/100mm U-PVC.
All gutters to be 150 Half Round Gutters
(7042mm² Cross section area).
Falls to be in accordance with clause 3.5.2.4,
Vol 2 of the NCC.

•     Effective roof catchment area (dwelling
                                                                                                                                                                                                                                                                                                                                            skylights
      only) 145 m²




                                                                                                                                                                                                                                                                                                                                                                                                                                  13700
•     Roof catchment per downpipe 50m²
•     Downpipes must not serve more than
      12m of gutter length for each downpipe
•     Total rainfall intensity 145m² X 258mm/50 =
      748.2L/min
•     Stormwater pipes - 100 dia. Laid at 1 in
      100 minimum grade.
Downpipes are to be located where they will                                                                                                                                                                                                                                                                                            Roof Catchment Area




                                                                                                                                                                                                                                                          8500
not create a hazard to building users nor                                                                                                                                                                                                                                                                                                     145m²
impede window & door openings and the
like.                                                                                                                                                                                                                                                                                                                                       kliplok roofing
                                                                                                                                                                                                                                                                                                                                                   3.0°
 They are to be installed as close as
practicable to the supporting structure while
maintaining termite inspection clearances of
                                                                                                                                                            1500mm setback

                                                                                                                                                                             2000mm setback

                                                                                                                                                                                              2500mm setback




25mm. Downpipes are to be protected from
potential mechanical damage, be installed
no less than 100mm from electrical cables &
gas pipes & no less than 50mm from other
services (AS3500.3.2 S4.11)




                                                                                                                                                                                                                                                          600




                                                                                                                                                                                                                                                                                                                                                                                                                                  600
Downpipes are to service 12m maximum                                                                                                                                                                           2500mm setback
gutter length & be within 1.2m from each                                                                                                                                                                       2000mm setback
valley unless overflow is provided for (NCC
Vol2 7.4.5)                                                                                                                                                                                                    1500mm setback                                             600                                                                     8500




                                                                                                                                                                                       Plan
                                                                                                                                                                                        Upper Level Pitching                                1 : 100




                                                                                                                                                                                                                                                                                                                                                                     No.                 Description                                          Date
                                                                                                                                            Project                                                                         Client                                 Drawing                                                                 Drawn by              A         Draft Issue A                                                  17/03/2025         Project number               Scale at A3
                                                                                                                                            19 Attunga Heights                                                              Bennett Residence                      ROOF DRAINAGE                                                           DRH                   B         Concept Issue B                                                20/03/2025
                                                   dennishillarchitect                                                                                                                                                                                             PLAN
                                                                                                                                                                                                                                                                                                                                                                                                                                                                      065                    1 : 100

                                            mobile: 0438 20 55 66 | [email protected]
                                                         www.dennishillarchitect.com                                                                                                                                                                                                                                                                                                                                                                          CONCEPT.09
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.   20/03/2025 8:00:29 PM

Page 33

                                                                                                                                                                                                                                                                                                                                                                                           Upper Level Pitching
                                                                                                                                                                                                                                                                                                                                                                                           RL 70.250 m




                                                                                                                                                                                                                                                                                                                                                                                           Upper Level
                                                                                                                                                                                                                                                                                                                                                                                           RL 67.550 m




                                                                                                                                                                                                                                                                                                                                                                                           Ground Level
                                                                                                                                                                                                                                                                                                                                                                                           RL 64.550 m




                                                                                                        1             Elevation
                                                                                                                      East Elevation                                                         1 : 100




                                                                                                                                                                                                                                                                                                                                                                                      Upper Level Pitching
                                                                                                                                                                                                                                                                                                                                                                                      RL 70.250 m




                                                                                                                                                                                                                                                                                                                                                                                      Upper Level
                                                                                                                                                                                                                                                                                                                                                                                      RL 67.550 m




                                                                                                                                                                                                                                                                                                                                                                                      Ground Level
                                                                                                                                                                                                                                                                                                                                                                                      RL 64.550 m




                                                                                                                                                                                                                                                                                                                                                                                      Basement Level
                                                                                                                                                                                                                                                                                                                                                                                      RL 61.850 m


                                                                                                                 2             Elevation
                                                                                                                               West Elevation                                                          1 : 100

                                                                                                                                                                                                                                                                                                                                                        No.                      Description                                         Date
                                                                                                                                            Project                                                  Client                                                        Drawing                                                Drawn by                  A              Draft Issue A                                                 17/03/2025                  Project number               Scale at A3
                                                                                                                                            19 Attunga Heights                                       Bennett Residence                                             ELEVATIONS                                             DRH                       B              Concept Issue B                                               20/03/2025
                                                   dennishillarchitect                                                                                                                                                                                                                                                                                                                                                                                                065                    1 : 100

                                            mobile: 0438 20 55 66 | [email protected]
                                                         www.dennishillarchitect.com                                                                                                                                                                                                                                                                                                                                                                          CONCEPT.11
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.   20/03/2025 8:00:32 PM

Page 34

                                                                                                                                                                                                                                   8m max heigh
                                                                                                                                                                                                                                                    t



                                                                                                                                                                                                                                                                                                                                                                                                                                Upper Level Pitching
                                                                                                                                                                                                                                                                                                                                                                                                                                RL 70.250 m




                                                                                                                                                                                                                                                                                                                                                                                                                                Upper Level
                                                                                                                                                                                                                                                                                                                                                                                                                                RL 67.550 m




                                                                                                                                                                                                                                                                                                                                                                                                                                Ground Level
                                                                                                                                                                                                                                                                                                                                                                                                                                RL 64.550 m


                                                                                                                                                                                                                        NGL



                                                      1             Elevation
                                                                    North Elevation                                                         1 : 100
                                                                                                                                                                                                                                                                                                                                                                                                                                Basement Level
                                                                                                                                                                                                                                                                                                                                                                                                                                RL 61.850 m




                                                                                                                                                                                                                                                                     height
                                                                                                                                                                                                                                                           8m max




                                                                                                                                                                                                                                                                                                                                                                                                                             Upper Level Pitching
                                                                                                                                                                                                                                                                                                                                                                                                                             RL 70.250 m




                                                                                                                                                                                                                                                                                                                                                                                                                             Upper Level
                                                                                                                                                                                                                                                                                                                                                                                                                             RL 67.550 m




                                                                                                                                                                                                                                                                                                                                                                          3000
                                                                                                                                                                                                                                                                                                                                                                                                                             Ground Level
                                                                                                                                                                                                                                                                                                                                                                                                                             RL 64.550 m
                                                                                                                                                                2278




                                                                                                                                                                                                                                          NG L




                                                                                                                                                                                                                                                                                                                                                                                                                             Basement Level
                                                                                                                                                                                                                                                                                                                                                                                                                             RL 61.850 m




                                        2             Elevation
                                                      South Elevation                                                         1 : 100
                                                                                                                                                                                                                                                                                                                                                        No.                      Description                                         Date
                                                                                                                                            Project                                                  Client                                                        Drawing                                                Drawn by                  A              Draft Issue A                                                 17/03/2025                  Project number               Scale at A3
                                                                                                                                            19 Attunga Heights                                       Bennett Residence                                             ELEVATIONS                                             DRH                       B              Concept Issue B                                               20/03/2025
                                                   dennishillarchitect                                                                                                                                                                                                                                                                                                                                                                                                065                    1 : 100

                                            mobile: 0438 20 55 66 | [email protected]
                                                         www.dennishillarchitect.com                                                                                                                                                                                                                                                                                                                                                                          CONCEPT.12
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.   20/03/2025 8:00:35 PM

Page 35

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     Upper Level Pitching
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     RL 70.250 m




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     Upper Level
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     RL 67.550 m
                                                                                                                                                                                                                                                                                                                    1000m(h) from pool side to provide fall-prevention




                                                                                                                                                                                                                                              500
 2470
2000




                                                                                                                                                                                                                                                                                                                           1000




                                                                                                                                                                                                                                                                                                                                                                                                                 1100
                                                                                                                                                                                                                                                                                    2000
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     Ground Level




                                                                                                                                                                                                                                                                                                                                                                             2746
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     RL 64.550 m




                                                                                                                                                                                                                                                                                                                                                                                                                                                  400




                                                                                                                                                                                                                                                                                                                                                                                                                                                                             400
                                                                                                                                                                                                                                                                                                                                                                                                   2000
               190        2740                          4280               100 1790                 2610        100                               8295
                                                                                2190
                                                                                                                                                                                                                                                             2051                                                     11695
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     Basement Level
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     RL 61.850 m

             1             Elevation                                                                                                                                                                                                          2             Elevation                                                                                                                   4000                             4000                           3400

                           East Elevation - Boundary Wall                                         1 : 150                                                                                                                                                   North Elevation - Boundary Wall                                         1 : 150




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   Upper Level Pitching
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   RL 70.250 m




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   Upper Level
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   RL 67.550 m




                                                                                                                                                                                                                                                                                                                                                                                             400
                                                                                                                                                                                                                                                                                                                                                                 400
                                                                                                                                                                                                                                                                                                                                         400
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   Ground Level




                                                                                                                                                                                                                                                                                                                  400




                                                                                                                                                                                                                                                                                                                                                                                      2000
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   RL 64.550 m




                                                                                                                                                                                                                                                                                            400
                                                                                                                                                                                                                                                                400
                                                                                          200




                                                                                                                                                                                                                          400
                                                                                                                                                                                             200




                                                                                                                                                                                                                                                                                     2000
                                                                                                                                                                                                                                                                                                                                             g lot
                                                                                                                                                                                                                                                                                                                                   ighbourin
                                                                                                                                                                                                                                                                                                                          NGL at ne
                                                                                                        2000




                                                                                                                                                                                                                                                                                                                                                                                    3200                    3000                    2800
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   Basement Level
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   RL 61.850 m

                                                                                                                                                                                                                                                 4546                            3000                     3000                    2400                  3200
                          2400                              5800                                                                     11905


                   4             Elevation                                                                                                                                                                                           3              Elevation
                                 West Elevation - Boundary Wall                                         1 : 150                                                                                                                                     South Elevation - Boundary                                             1 : 150
                                                                                                                                                                                                                                                    Wall




                                                                                                                                                                                                                                                                                                                                                         No.                    Description                                           Date
                                                                                                                                             Project                                                  Client                                                          Drawing                                              Drawn by                  A              Concept Issue B                                               20/03/2025                  Project number                Scale at A3
                                                                                                                                             19 Attunga Heights                                       Bennett Residence                                               BOUNDARY                                             DRH
                                                    dennishillarchitect                                                                                                                                                                                               WALLS
                                                                                                                                                                                                                                                                                                                                                                                                                                                                       065                    1 : 150

                                             mobile: 0438 20 55 66 | [email protected]
                                                          www.dennishillarchitect.com                                                                                                                                                                                                                                                                                                                                                                          CONCEPT.13
 Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.   20/03/2025 8:00:39 PM

Page 36

                                                          ABN 51 640 311 842
                                                          arcosgroup.com.au
                                         Sunshine Coast | Brisbane | Gold Coast




   Contact Us

          07 5293 7648

          @arcosgroup

          [email protected]

          arcosgroup.com.au



Sunshine Coast | Brisbane | Gold Coast

Used in these records

About this file

File size
11.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Slope Stability Report (rec. 16.04.25).pdf · 11.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.