ROOF DRAINAGE
NOTES:
All work to conform with Part MP 4.2 of the 600 1500 7000
Queensland Development Code (QDC)
(Water Saving Targets).
6000mm setback
4500mm setback
Roof stormwater is to discharge to local
government requirements and approval.
Tank/s overflow and downpipes not
connected to rainwater tank/s to discharge
600
600
to interallotment drainage system/ to
nominated discharge points via bubbler
system/ to discharge to street channel system.
Based on assumed 5 minute rainfall intensity -
258mm/h 20 years recurrence interval.
line of upper level walls under
Gutters & downpipes shall be in accordance
5200
with AS/NZS3500.5 domestic & Part 3.5.2, Vol 2
of the NCC.
All downpipes to be 90mm/100mm U-PVC.
All gutters to be 150 Half Round Gutters
(7042mm² Cross section area).
Falls to be in accordance with clause 3.5.2.4,
Vol 2 of the NCC.
• Effective roof catchment area (dwelling
skylights
only) 145 m²
13700
• Roof catchment per downpipe 50m²
• Downpipes must not serve more than
12m of gutter length for each downpipe
• Total rainfall intensity 145m² X 258mm/50 =
748.2L/min
• Stormwater pipes - 100 dia. Laid at 1 in
100 minimum grade.
Downpipes are to be located where they will Roof Catchment Area
8500
not create a hazard to building users nor 145m²
impede window & door openings and the
like. kliplok roofing
3.0°
They are to be installed as close as
practicable to the supporting structure while
maintaining termite inspection clearances of
1500mm setback
2000mm setback
2500mm setback
25mm. Downpipes are to be protected from
potential mechanical damage, be installed
no less than 100mm from electrical cables &
gas pipes & no less than 50mm from other
services (AS3500.3.2 S4.11)
600
600
Downpipes are to service 12m maximum 2500mm setback
gutter length & be within 1.2m from each 2000mm setback
valley unless overflow is provided for (NCC
Vol2 7.4.5) 1500mm setback 600 8500
Plan
Upper Level Pitching 1 : 100
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence ROOF DRAINAGE DRH B Concept Issue B 20/03/2025
dennishillarchitect PLAN
065 1 : 100
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com CONCEPT.09
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 20/03/2025 8:00:29 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Slope Stability Report (rec. 16.04.25).pdfRelated documentApplication case desk ↗
About this file
- File size
- 11.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.