Council archive · source document
08/0946 - MCU - Detached House [As Published] · 132008.946
DETACHED HOUSE CODE
Specific Outcomes and Acceptable Solutions
SPECIFIC OUTCOMES
non-habitable areas;
c) ensure drainage does not adversely impact upon other
premises; and
d) ensure filling or excavation does not adversely impact
upon other premises by—
i. causing ponding of water on the sife or nearby land; and
ii. increasing flooding, which adversely affects the safety or
use of any land upstream and downstream; and
ili, adversely affecting the flow of water in any overland flow
path.
AND
03 Development does not adversely impact on the Lake
Macdonald water supply.
ACCEPTABLE SOLUTIONS
levels are available—not less than
the specified level;
b) for areas where flood modelling is
available—a minimum of 500mm
above the modelled flood level; and
c) for areas where flood modelling is
not available, a minimum of 500mm
above the highest known flood
level:18 or
$2.2 For additions of not more than
50m2 to an existing building or
structure —floor levels of habitable
rooms are not less than the level of
other habitable rooms in the building
or structure;
AND
$2.3 Filling, other than accessways,
does not extend more than im
beyond the footprint of any building
or structure, measured from outer
walls of the building or structure.
Advisory note
Council encourages _ building
methods that avoid the use of fill
such as suspended floor construction
COMPLIANCE
NIA
COMMENTS
required by Council. Excavation is required
to allow for the basement facilities this area
at the lowest point is 0.400m AHD. This area
is not defined as a habitable room as the
land uses are of a specialised nature, being
car parking and gymnasium. These facilities
will not be occupied for extended periods of
time, for this reason the risk of flood impacts
are reduced.
$2.2 Not Applicable
The proposal is not for an extension to an
existing development.
$2.3 Compliant
The proposal involves the excavation of
760m3 of fill and 300m? of backfill. The
excavation does not exceed outside the
building footprint or structure.
* Solution: ~ = Acceptable Solution
AIS = Altemative Solution
N/A = Not applicable to this proposal
49 Wyuna Drive, Noosaville
Page 2
e CONICS b
COUNCIL Wits
ce], a
| |
Attachment 1
Detached House Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0946 - MCU - Detached House [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.