TIMBER TRUSSESS @ 600 CRS FITTED IN
ACCORDANCE WITH MANUFACTURER'S SPEC. 15 DEGREE PITCH NOTE:
COLORBOND SHEET ROOFING FITTED IN ACCORDANCE 1. Emergency lift off hinges to all wc's.
WITH MANUFACTURER'S SPEC. FOR N3 WIND LOADS OR 2. Mechancial ventilation to all Bathrooms and Ensuites.
TO ENGINEER'S REQUIREMENTS. 3. All demolished material including rubble, all tree parts and building products to be removed
from site and disposed of in accordance with local authorities.
5. All workmanship and material to be in accordance with the latest building regulations and
relevant codes and standards including amendments and to manufacturer's specifications.
6. Check rwp requirements for each region, as shown are suggested only.
7. Builder to ensure all plans are in compliance with Australian Standards and Building Codes.
8. Provide Safety Glass to bathrooms and other areas where required.
PLASTERBOARD 9. Pipe all stormwater from roof to Rainwater tank.
3000 APPROX.
INTERNAL LINING TO WALLS, 10. Smoke alarms to be hard wired in accodance with relevant codes and standards.
CEILING AND BULKHEADS
TIMBER FRAMED WALLS
2400
TO ENGINEER'S DESIGN
DECKING AND FLOOR
STRUCTURE
TO ENGINEERING DESIGN
50
PIERS
TO ENGINEERING DESIGN
A
A201
OFFICE - NORTH EAST ELEVATION OFFICE - SOUTH EAST ELEVATION OFFICE - SECTION A-A
SCALE : 1 : 100 SCALE : 1 : 100 SCALE : 1 : 100
15 Deg
CRS CRS
CRS CRS
15 Deg 15 Deg
15 Deg
OFFICE ROOF PLAN
SCALE : 1 : 100
LIFT UP PASS
1100
2100 x 1500 900 x 1500
DECK SLIDING DOOR SLIDING WINDOW
OFFICE - NORTH WEST ELEVATION OFFICE - SOUTH WEST ELEVATION
90
SLIDING WINDOW
775
DESK 50mm
600 x 900
OPAQUE
SCALE : 1 : 100 SCALE : 1 : 100
HIGH COUNTER
SLIDING DOOR
JETTY
2100 x 1800
4730
2530
2350
800
OFFICE
775
DESK
90
900 x 1500 900 x 1500
SLIDING WINDOW SLIDING WINDOW
1100
3320 600 300 1700
90 1100 90 1070 90 5920 90
KEY CSR COLORBOND
SHEET ROOF
HT 1600 8450 2100
HOSE TAP
SW STORM WATER
12150
FLOOR GULLY S SMOKE ALARM
FG
HW HOT WATER
DOWN PIPE
DP
F FRIDGE OFFICE FLOOR PLAN
N
D DOOR
FLAT ROOF SCALE : 1 : 100
CSD CAVITY SLIDING DOOR FLR
CLIP LOCK OR
W WINDOW
SIMILAR
APPROVED PLANS
PD PLUMBING DUCT
RH RAIN HEAD OPW17/0024
FALL DIRECTION
3D VIEW OFFICE
NOOSA COUNCIL
Preliminary
SP SPITTER A/C AIR-CONDITIONER
UNIT
18 MAY 2017
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Osco Finance
Use written dimensions only. DO NOT scale drawings. Contractors to verify all Office Floor Plan and Elevations SITE ADDRESS: 9 Cardell Road, Tewantin
dimensions and levels on site prior to commencing works and shop drawings.
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and details, DRAWING No:
Oct 2016
A201
ISSUE: B DATE: 17/02/2017 DATE:
the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 If in doubt, please request clarification. DO NOT ASSUME. SCALE: 1 : 100 SHEET SIZE: A3