Council archive · source document
Application Report · MCU10/2113.03
20 Peregian Esplanade, Peregian Beach PERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES PROPOSAL COMPLIANCE to safely access a vessel from the jetty. AO13.9 AO13.9 All attachments to jetties, including but The subject site is not located within tidal areas ☐Compliant not limited to boat lifts, jetski cradles, or the waterways of the Noosa Waters Estate. ☒N/A floating berths and floating pontoons are As such, this criterion is not applicable. ☐Performance Solution located within the quay line. AO13.10 AO13.10 Pontoons are structurally capable of The subject site is not located within tidal areas ☐Compliant sitting on the sand bed. Rollers and or the waterways of the Noosa Waters Estate. ☒N/A bracing should account for this situation As such, this criterion is not applicable. ☐Performance Solution AO13.11 AO13.11 Jetties and pontoons are free standing The subject site is not located within tidal areas ☐Compliant and do not rely on connecting to any or the waterways of the Noosa Waters Estate. ☒N/A revetment wall or other structure. As such, this criterion is not applicable. ☐Performance Solution Design, Construction and Safety for Boat Ramps - prescribed tidal works outside Noosa Waters Estate PO14 AO14.1 AO14.1 Boat ramps are designed and Where there is an existing revetment The subject site is not located within tidal areas ☐Compliant constructed to— wall— or the waterways of the Noosa Waters Estate. ☒N/A a) allow access by a wheeled boat a) the level of a boat ramp surface at As such, this criterion is not applicable. ☐Performance Solution trailer; the revetment wall is no more than b) ensure that unacceptable risks to 150 millimetres above the top of personal and public safety are the wall, not more than 500 unlikely to be caused; millimetres below the top of the c) avoid cluttering of the waterways; wall and not more than 200 d) avoid excessive traffic volumes millimetres above the existing within foreshore areas and beach; adjoining lands; and b) the ramp extends into the waterway no more than 9 metres 142
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Application Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.