Log in to see the plans as drawnGENERAL NOTES:
DRAWINGS PROVIDED ARE FOR ARCHITECTURAL DESIGN PURPOSES ONLY. CONSTRUCTION
MUST REFER TO STRUCTURAL ENGINEERING DOCUMENTATION AND LOCAL BUILDING CERTIFIER
FOR CORRECT BUILDING METHOD, MATERIALS ETC. IN NO WAY ARE THESE DRAWINGS TO BE
USED FOR CONSTRUCTION.
DRAWINGS TO BE READ IN CONJUNCTION WITH OTHER CONSULTANTS DOCUMENTATION.
REFER ANY DISCREPANCIES TO THE RELEVANT CONSULTANT FOR WRITTEN DIRECTION.
THIS SET OF PLANS IS SUFFICIENT TO OBTAIN A BUILDING PERMIT; HOWEVER, ALL
MATERIALS AND METHODS OF CONSTRUCTION NECESSARY TO COMPLETE THE PROJECT
ARE NOT NECESSARILY DESCRIBED. THE PLANS DELINEATE AND DESCRIBE ONLY LOCATIONS,
DIMENSIONS, TYPES OF MATERIALS AND GENERAL METHODS OF ASSEMBLING OR FASTENING
AND OTHER CONSULTANTS DOCUMENTATION SPECIFIES THE PARTICULAR PRODUCTS,
MATERIALS AND TYPE OF CONSTRUCTION RECOMMENDED FOR THIS DESIGN.
DIMENSIONS TAKE PRECEDENCE OVER SCALED MEASUREMENTS. DETAILS AND SECTIONS ON
THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL
REQUIREMENTS THROUGHOUT. DETAILS NOTED "TYPICAL" IMPLY ALL LIKE CONDITIONS
TREATED SIMILARLY, UNLESS NOTED OTHERWISE. THE ARCHITECTURAL DETAILS SHOWN ARE
INTENDED TO FURTHER ILLUSTRATE THE VISUAL DESIGN CONCEPT AND THE MINIMUM
RECOMMENDED WEATHER PROTECTION FOR THIS PROJECT. BUILDING CODE REQUIREMENTS,
OTHER CONSULTANTS DOCUMENTATION AND PRODUCT MANUFACTURER'S WRITTEN
INSTRUCTIONS SHALL ALSO BE CONSIDERED IN ORDER TO COMPLETE THE CONSTRUCTION OF
THE DETAILS, AND IN SOME CASES MAY SUPERSEDE THE DETAILS.
THE BUILDER AND ALL SUB CONTRACTORS SHALL REVIEW THE FULL CONTENT OF THE PLANS
FOR DISCREPANCIES AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. THE BUILDER AND
SUB CONTRACTORS SHALL BE RESPONSIBLE FOR ANY WORK NOT IN CONFORMANCE WITH THE
PLANS OR IN CONFLICT WITH ANY RELEVANT CODE.
ALL CONSTRUCTION SHALL COMPLY WITH THE MOST STRINGENT REQUIREMENTS OF ALL
CURRENT APPLICABLE STATE AND COUNCIL LAWS, RULE, CODES AND REGULATIONS. IF THE
Subject Site
BUILDER OR ANY SUB CONTRACTOR PERFORMS ANY WORK IN CONFLICT WITH THE ABOVE
MENTIONED LAWS, THEN THE CONTRACTOR IN VIOLATION SHALL BEAR ALL COSTS OF
REPAIR ARISING OUT OF THE NON-CONFORMING WORK.
THE BUILDER IS RESPONSIBLE TO CHECK ALL EXISTING SERVICES PRIOR TO BEGINNING
CONSTRUCTION. BUILDER TO VERIFY PROPERTY BOUNDARIES AND BUILDING LINES PRIOR
TO COMMENCEMENT OF WORKS IN ASSOCIATION WITH APPROVALS.
ALL SERVICES INCLUDING FIRE FIGHTING SERVICES, OCCUPANT WARNING SYSTEMS,
LIGHTING, POWER, WATER SUPPLY, SANITARY DRAINAGE, STORMWATER, MECHANICAL
VENTILATION AND AIR CONDITIONING TO BE IN ACCORDANCE WITH RELEVANT
CONSULTANTS DETAILS.
ALL STRUCTURAL ELEMENTS TO BE IN ACCORDANCE WITH ENGINEERS DESIGN AND DETAILS.
WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH RELEVANT CURRENT,
SAA CODES AND STATUTORY AUTHORITIES REQUIREMENTS.
ANY ADDITION OR DELETION OR CHANGE IN THE SCOPE OF WORK DESCRIBED BY THE PLANS
SHALL BE BY WRITTEN APPROVAL TO THE RELEVANT CONSULTANT.
Design Information
• Address: 33 Rene Street, Noosaville 4566
• Lot & Plan: Lot 52 Plan RP187152
• Local Government (Council): Noosa Shire
• Industry Zone
• Site Area 1054m2
• Proposed fitness business
Council Approval
Proposed Fitness Business
collinsbuildingdesigns.com.au 33 Rene St, Noosaville
Date: 24.07.2018
Mob: 0474 141 348
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 3 pages
Page 2
D E N
G A R
Lot 51
RP187152
T
E
b o u n d a r y
bike parking bay bike parking bay
E
y
15 6
1
r
R
a
d
2
T
Lot 52
n
T
N
7
RP187152
u
3
14
E
o
S
y
M
b
r
4
D E N
E
a
d
S
undercover parking 8
5
A
13
n
G A R
E
u
o
existing carpark
b
to be landscaped 12 11 10 9 Turn area to be kept
around clear at all times
b o u n d a r y
bay
driveway to be used as SH ARED CONCRETE DRIVEWAY
access to rear carprk
E
Lot 53
N
RP 187152
E
D E N
R
G A R
Council Approval
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Site Plan Proposed Fitness Business
33 Rene St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Pegasus PT Scale: 1 : 300 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Date: 24.07.2018 Rev: A01_ A102
Page 3
9450 27950 13000
90 3574 90 24106 90
90
90
3515
Entry Sled Tracks
15 79m2 6
1
90
2
5207
Entry
Grassed Area
105m2
17185
7
3
90
14
walkway
5276
Office
4
Rubber floor various weights 8
145m2
90
undercover
5
parking
2917
13
Toilets
90
90
3235
12 11 10 9
b o u n d a r y
9450 90 4952 90 22728 90 13000
Council Approval
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Ground Floor Plan Proposed Fitness Business
33 Rene St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Pegasus PT Scale: 1 : 150 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Date: 24.07.2018 Rev: A01_ A103
Page 4
9450 27950 13000
90 3574 90 24106 90
90
90
3515
15
6
1
90
2
5207
17185
7
3
90
14
4
Kitchen
8283
undercover 8
parking
5
13
90
90
12 11 10 9
3235
b o u n d a r y
9450 90 4952 90 22728 90 13000
Council Approval
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Upper Floor Plan Proposed Fitness Business
33 Rene St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Pegasus PT Scale: 1 : 150 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Date: 24.07.2018 Rev: A01_ A104