Request for Further Information - 010.2007.00002179.001 [As Published] · 172007.2179

of 2

Text shows just the words. Original shows the document exactly as it was published.

                                                       Duncan Thompson – Ph. 5449 5175
                                                       Email: [email protected]
                                                       Application Ref: 2007/2179




5 November 2007


R. J. Neller
CARE R. J. Neller
PO Box 284
PEREGIAN BEACH QLD 4573




Dear Rick,

Re: Application for a Development Permit for 07/2179 Preliminary Building
    Work Assessable Against the Planning Scheme situated at 66 Tingira
    Crescent SUNRISE BEACH described as LOT: 30 RP: 126838

I refer to the above application and wish to advise that following preliminary
examination of the plans, the following information is required to be submitted:-
1.      Amended plans that demonstrate that the proposed works comply with
        acceptable solution S1.3 of the Building Works Code with respect to setbacks.

2.      Amended plans that demonstrate that the proposed works comply with Specific
        Outcome O6 of the Building Works Code with respect to the maximum number of
        stories.

        Your attention is drawn to applicable administrative terms described in The
        Noosa Plan.
        Building height in storeys means the number of storeys in a building measured vertically at
        any point, provided that a basement shall not count as a storey. Despite this parking
        accommodation is to be regarded as a storey, even if it is in a basement unless access to
        such parking accommodation is limited to one opening a maximum of 6m wide only.

        Basement means a space where the ceiling height is either below natural ground surface or
        does not project more than one metre above natural ground surface.


3.      Amended plans that demonstrate that the proposed works comply with probable
        solution S17.2 of the Natural Resources Overlay Code with respect to
        cantilevered decks as described below.
        S17.2 Cantilevered decks that are uncovered and unenclosed located seaward of the coastal
        building line:
        a) do not extend seaward of the average of the outermost seaward projection of buildings on
            directly adjoining properties; and
        b) are a maximum depth of 3m;
        c) are setback a minimum of 6m from the seaward boundary of the site.




     Award Winner - Australian Clean Beach
       Challenge 2004 Litter Prevention
Full text of the other 1 page

Page 2

Please provide four copies of all information that you are providing. In addition, it
would assist Council if you could also provide an electronic copy of your response.
Please be aware that under Section 3.2.12 of the Integrated Planning Act, the applicant
is to respond to any information request within 12 months of the request or otherwise,
the application lapses.
Under the provisions of the Integrated Planning Act 1997, you as the applicant, have
three options available in response to this Information Request. You may give the
assessment manager (in this instance Council) and each referral agency (if any):-

1.      all of the information requested; or

2.      part of the information requested together with a letter asking the assessment
        manager and each referral agency to proceed with the assessment of the
        application; or

3.      a letter:-

        3.1. stating that you do not intend to supply any of the information requested;
             and

        3.2. asking the assessment manager and each referral agency to proceed with
             the assessment of the application.
The above information is required to be submitted, prior to assessment of the
application. If any further matters arise as part of assessment of this application, you
will be advised accordingly.

Should you have any further queries in relation to the above, please do not hesitate to
contact Duncan Thompson on the above number.

Yours faithfully,



Daniel Smith
ASSISTANT PLANNING OFFICER




     Award Winner - Australian Clean Beach
       Challenge 2004 Litter Prevention

Used in these records

About this file

File size
12 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Request for Further Information - 010.2007.00002179.001 [As Published].pdf · 12 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.