Skip to the record
The only place to find full transcripts.

Original source · versioned page text

Compiled Plans & Documents OPW18-0342 02.pdf

of 192

Page text read automatically using OCR, there may be inaccuracies

                                                                          Bushfire Constraint Assessment – Peer Review
                                                                                                BlueCare, Sunrise Beach



 Bushfire
 Mitigation                LandGraphics 2009          2016 Requirements            Comment
 Measures
 Fire hydrants             reticulated water supply   reticulated water supply
                           and relevant Australian    and fire hydrants in
                           Standard                   accordance with AS 2419
                                                                                   Agree with 2009 recommendation
 Gas and Electricity       Comply with AS1596         No specific requirements     (and electrical lines are to be located
                                                                                   underground)
                                                      Construction requirements
                           Construct buildings to
 Building Construction                                based on BAL – calculated    BALs must be recalculated – target to
                           Level 1 and 2 per
 Standards                                            using Method 2 detailed in   be no greater than BAL-29.
                           AS3959-1999
                                                      AS3959-2009
 Street Numbering          Clear and easily
                                                      No specific requirements     Agree with 2009 recommendation
 and Identification        identifiable
                                                      No specific requirements
 Internal Roads            2 wheel drive              (no cul-de-sacs for lot      Agree with 2009 recommendation
                                                      reconfigurations)
 First Aid Fire Fighting   Install fire hose reels    No specific requirements     Agree with 2009 recommendation
                                                      No specific requirements –
                           Prepare Evacuation
 Evacuation Plan                                      but required by Decision     Evacuation Plan must be prepared
                           Plan
                                                      Notice.
                           Consider requirements
 Landscaping                                          No specific requirements     Agree with 2009 recommendation
                           of APZ
 Maintenance               Regular maintenance        No specific requirements     Agree with 2009 recommendation




PR132938; Final / October 2016                                                                                    Page 11

Log in to download the original (Compiled Plans & Documents OPW18-0342 02.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.