                              BOLTS OR NAILS AS PER TABLE
                              9.4.2(viii). BLOCKS TO BE BOTH SIDES
                              OF RAFTER OR BOTTOM CHORD
                                                                                                                                                         INTERNAL BRACING WALL
                                                                                                                                                                                                                       GENERAL NOTES:
                                                                TRUSS                                                                                                                                                  GN01-VERIFY ALL DIMENSIONS, LEVELS, SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING ANY WORKS OR ORDERING MATERIALS.
                                                                                                                                                                                TOP PLATE                               ENSURE THAT ALL BUILDING WORKS CONFORM TO THE NATIONAL CONSTRUCTION CODE (NCC) OF AUSTRALIA, CURRENT AUSTRALIAN
                                                                                                                                                                                                                       STANDARDS, BUILDING REGULATIONS, LOCAL BY-LAWS AND TOWN PLANNING REQUIREMENTS. REPORT ALL DISCREPANCIES TO THIS
                                                                                                                          STUD                                                                                         OFFICE FOR CLARIFICATION.
                                                                                                                                                                                                                       GNO2-THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL ENGINEERING DRAWINGS.
                                                                                           BRACING WALL                                                                                                                GN03-THE CONTRACTOR SHALL CARRY OUT THE WORK IN ACCORDANCE WITH THE N.C.C, AUSTRALIAN STANDARDS & LOCAL AUTHORITY
          BLOCKING PIECES LARGE ENOUGH
                                                                                                                                                                                                                       REQUIREMENTS.
          TO AVOID SPLITTING                                                                                                                                                        EXTERNAL WALL
                                                                                                                                                                                                                       GN04-ALL SERVICES ARE TO COMPLY WITH PART 3.12.5 OF THE N.C.C.
                                                                                                                                                                                                                       GN05-ALL WET AREAS TO COMPLY WITH NCC 3.8.1 AND AS.3740 - 2010. WALL FINISHES SHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm
                                                                                                                         30 x 0.8 mm G.I. STRAPS                                                                       ABOVE FLOOR LEVEL TO SHOWER ENCLOSURES, AND 150mm ABOVE BATHTUBS, BASINS, SINKS AND TROUGHS IF WITHIN 75mm OF THE WALL, U.N.O.
         FORCE MUST BE                                                                 GAP MUST BE PROVIDED
         TRANSFERRED IN                                                                                                  WITH NUMBER OF NAILS EACH                                                                     GN06-PROVIDE NOGGINGS TO WET AREA ROOMS TO SECURE FIXING OF ACCESSORIES INCLUDING TOWEL RAILS, SHOWER BASKET, HAND
                                                                                       TO ALLOW FOR TRUSS
         THIS DIRECTION                                                                                                  END OF STRAP AS PER                                                                           DRYERS AND TOILET ROLL HOLDERS.
                                                                                       DEFLECTION
         TO WALL                                                                                                         TABLE FIGURE 9.4.2(ix)                                                                        GN07-W.C DOORS TO COMPLY WITH NCC ie: HAVE LIFT OFF HINGES, OPEN OUTWARD, SLIDING DOOR OR TO HAVE 1.2M BETWEEN THE PAN AND
                                                  WALLS AT                                                                                                                    STUDS
                                                                                                                                                                                                                       THE DOORWAY
                                                  RIGHT ANGLES
                                                                                                                                                                                                                       GN08-ALL DOORS LEADING TO EXITS, AND IN EXITS, ARE TO BE FITTED WITH DOOR FURNITURE
                                                                                                                                                                                                                       GN09-MOUNTED BETWEEN 900mm & 1200mm ABOVE FLOOR LEVEL, AND BE CAPABLE OF BEING OPENED BY A SINGLE-HANDED DOWNWARD
                              BRACING WALL TO TRUSSES / CEILING & FLOOR JOISTS                                            BRACING WALL TO EXTERNAL WALL
                                                                                                                                                                                                                       ACTION ON A SINGLE DEVICE WITHOUT THE USE OF A KEY, FROM THE DIRECTION THAT A PERSON WOULD SEEK EGRESS.
                                                                                                                                                                                                                       GN10-VERIFY ALL STRUCTURAL REQUIREMENTS BEFORE AND DURING CONSTRUCTION.
                                                                                                                                                                                                                       GN11-SMOKE DETECTORS TO BE DIRECT MAINS WIRED WITH BATTERY BACK UP AND TO COMPLY WITH 3786 - 1993
                                                                                                                                                                                                                       GN12-PROVIDE ELECTRICAL SAFETY SWITCHES TO ALL SWITCHBOARDS.
                                                                                                                                                                                                                       GN13-ENSURE ALL NEW AND EXISTING WORKS ARE WATERTIGHT.
                                                                                                                                                                                                                       GN14-SEWER SHALL BE IN ACCORDANCE WITH THE RELEVANT AUTHORITY'S REQUIREMENTS. STORMWATER SHALL BE TAKEN TO LEGAL POINT
                                                                                                                                                                                                                       OF DISCHARGE TO THE SATISFACTION OF THE RELEVANT AUTHORITY.
                                                                                                                                                                                                                       GN15-FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES AND EASEMENT LINES.
                                                                               TWO LOOPED STRAPS (30 X 0.8mm G.I.)                                                                                                     GN16-PROVIDE FULL HEIGHT BRICKWORK ARTICULATION EXPANSION JOINTS OPEN AT MAX. 6.0M CENTRES OR AS REQUIRED BY ENGINEER
                  F8 - 100 X 38                                                4/2.8mm DIA. NAILS EACH END                                                                                                             AND THE SOIL REPORT.
                  BRIDGING PIECE                                               AND TO BRIDGING                                                                                                                         GN17-PROVIDE WALL TIES TO BRICKWORK AT MAXIMUM 600mm CENTRES IN EACH DIRECTION AND WITHIN 300MM OF ARTICULATION JOINTS.
                                                                                       30° MAX.                                                                                                                        GN18-ENSURE THAT ALL STEEL WORK, BRICK CAVITY TIES, AND STEEL LINTELS, ETC. THAT ARE
                                                                                                                                                                                                                       GN19-IMBEDDED OR FIXED INTO MASONRY BE PROTECTED IN ACCORDANCE WITH A.S. 1650 OR A.S. 3700- 2012 TABLE 2.2, HOT DIPPED GALV.,
                                                                                                                                                                                                                       S/LESS STEEL OR CADMIUM COATED.
                                                                                                                          2 nailing plates each end of                                                                 GN20-PROVIDE CAVITY FLASHING AND PROVIDE WEEP HOLES EVERY SECOND PERPEND MIN. 2 BRICK COURSES ABOVE & BELOW WINDOWS
                                                                                                                                                                       M 10 Bolts
                                                                                                                          bridging, legs not bent
                                                                                                                                                                                                                       WHERE REQUIRED
                                                                                                                          with 6/2.8 mm Ø nails to
                                                                                                                                                                                                                       GN21-WINDOW SIZES ARE NOMINAL ONLY ACTUAL SIZES WILL VARY ACCORDING TO MANUFACTURER. WINDOWS TO BE FLASHED ALL AROUND.
                                                                                                                          each face
                                                                                                                                                                                                                       ALL WINDOW OPENINGS ARE TO BE MEASURED ON SITE PRIOR TO MANUFACTURE
                                                                                             3/75 X 3.15mm                                                                                                             - ALL INTERNAL GLAZING TO BE IN ACCORDANCE WITH AS1288-2006 AND ALL EXTERNAL GLAZING TO BE IN ACCORDANCE WITH AS2047-1999
                            GAP TO                                                           DIA. NAILS                                                                                                                GN22-SOIL CLASSIFICATION - THESE PLANS SHALL BE READ IN CONJUNCTION WITH THE SOIL REPORT BYTHE RELEVANT ENGINEER
                            TRUSS                                                                                                                                                                                      GN23-FOOTINGS TO BE FOUNDED AT THE MINIMUM DEPTHS AS INDICATED IN THE SOIL REPORT.
                                                                                                                                                                                                                       (OR AS PER ENGINEERS DETAILS)
                                                                             TRUSS
                                                                                                                                                     100 X 50 mm bridging piece                                        GN24-INSTALL ALL WALL AND ROOF BRACING AS REQUIRED BY AS1684.4 SECTION 8
                                                                                                                                                     on edge                                                           GN25-SWIMMING POOL SAFETY REQUIREMENTS MUST BE INSTALLED IN ACCORDANCE WITH AS1926.1- 1993 & AS1926.2-2007
                                                                        BRACING WALL
                                                                                                                                                                                                                       GN26-ALL EXPOSED DOWNPIPES ARE TO BE ZINCALUME OR SELECTED COLORBOND FINISH. PROVIDE 90mm DIA HEAVY DUTY PVC DRAIN
                            WALLS PARALLEL
                                                                                                                                                                                                                       MINIMUM 1:100 FALL. PROVIDE MINIMUM 75mm DOWN PIPE AT 12m CENTRES,
                            BRACING WALL TO TRUSSES & CEILING JOISTS                                                         BRACING WALL TO FLOOR JOISTS                                                              GN27-EXTERNAL CLADDING TO BE INSTALLED AND WATERPROOFED TO MANUFACTURES SPECIFICATIONS

                                                                                                                                                                                                                       GN28-ALL WORKS SHALL COMPLY WITH, BUT NOT LIMITED TO, THE CURRENT/RELEVANT EDITION OF THE BCA AND THE
                                                                                                                                                                                                                       FOLLOWING AUSTRALIAN STANDARDS:
                                                                                                                                                                                                                       AS 1288 GLASS IN BUILDINGS - SELECTION AND INSTALLATION
                                                                                                                                                                                                                       AS 1562 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING
                                                                                                                                                                                                                       AS 1684 RESIDENTIAL TIMBER FRAMED CONSTRUCTION- NON CYCLONIC
                                         Nailing plates or framing                                                                                                                                                     AS 1720 TIMBER STRUCTURES
                                         anchor (legs not bent)                                                                                                                                                        AS 1860.2 PARTICLEBOARD FLOORING - INSTALLATION
                                         to either end of nogging                                                                                                                                                      AS 2049 ROOF TILES
                                         6/2.8 mm Ø nails each face                                                                                                                                                    AS 2870 RESIDENTIAL SLABS AND FOOTINGS
                                                                                                                                                                                                                       AS 2904 DAMP-PROOF COURSES AND FLASHINGS
                      Shear blocks                                                                                                                                                                                     AS 3600 CONCRETE STRUCTURES
                      nailed or bolted                                   100 x 30 mm                                                                                                                                   AS 3660 TERMITE MANAGEMENT - NEW BUILDING WORK
                      as per table                                       nogging                                                                                                                                       AS 3700 MASONRY STRUCTURES
                      Fig 9.4.2. (VI)                                                                                                                                                                                  AS 3740 WATERPROOFING FOR DOMESTIC WET AREAS
                                                                                                                                                                                                                       AS 3786 SMOKE ALARMS
                                                                                                                                                                                                                       AS 4055 WIND LOADS FOR HOUSING
                                                                                                                                                          M 10 Bolts
                                                                                                                                                                                                                       AS 4100 STEEL STRUCTURES
                                                                                                                                                                                                                       AS 4440 INSTALLATION OF NAIL PLATED TIMBER ROOF TRUSSES
                                                                                                                                                                                                                       AS 3500 GUTTERS & DOWN PIPES

                                                                                                                                                                                                                       THESE NOTES ARE NEITHER EXHAUSTIVE, NOR A SUBSTITUTE FOR REGULATIONS, STATUTORY REQUIREMENTS,
                          GAP TO TRUSS                                                                                                                                                                                 BUILDING PRACTICE OR CONTRACTUAL OBLIGATIONS,
                                                                                                                                                                                                                       AND UNLESS EXPRESSLY STATED OTHERWISE, ARE PROVIDED ONLY AS GUIDELINES.
                                                               BRACING WALL
                                                                                                                              Double joist or 450 mm long full depth cleat
                                                                                                                              nailed to joist with 6/75 x 3.15 mm Ø nails


                               TRUSSES PARALLEL TO BRACING WALL                                                               BRACING WALL TO FLOOR JOISTS




© COPYRIGHT. THIS DRAWING REMAINS THE PROPERTY OF G.J GARDNER HOMES & IS PROVIDED FOR THE USE AS DESCRIBED & MAY NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. ANY LANDSCAPING (WHEN SHOWN) ARE FOR ILLUSTRATIVE PURPOSES ONLY AND DO NOT FORM PART OF ANY CONTRACT.
                                                                                                                                                                                                                                                            PAGE: SHEET SIZE: REV DRN CHK DETAILS                        DATE:
                                                                                                                                           CLIENT:                                                  PROJECT ADDRESS:       PROPOSED NEW RESIDENCE              10      A3
                                                                                                                                                                                                                                                                                                                                   I/WE HAVE CHECKED THE PLANS AND AGREE THAT
                                                                                                                                                                                                                                                                                                                                   THEY ACCURATELY DEPICT THE HOUSE FOR
                                                                                                                                                                                                                                                                                  MM MM CONCEPT DRAWINGS FOR PRICING    25.01.21
                                                                         CUSTOM                                                            Steven Turvey                                                                                                    JOB NUMBER:           MM MM CONSTURCTION SET INC. AMENDS    26.03.21
                                                                                                                                                                                                                                                                                                                                   CONSTRUCTION.

                                                                                                                                                                                                    6 & SP253957                                            Job Number            MM MM RFI AMENDS                      15.04.21
                                                                                                                                                                                                                                                                                                                                   JOB SPECIFICATION BY BUILDER TAKES
                                                                                                                                                                                                                                                                                                                                   PRECEDENCE OVER THESE PLANS.
         GJ NOOSA PTY LTD                                                                                                                  DRAWING TITLE:                                           18 Yatama Plc,                                          SALESPERSON:

               QLD                                                                                                   QLD                                                                            Cooroibah                                               Chris Mcneil                                                           OWNER SIGNED: ............................... DATE: ..........
                                                                      © COPYRIGHT EXCLUSIVE                                                                                                                                                                 DATE:                                                                  OWNER SIGNED: ............................... DATE: ..........
           QBCC 1303975                                               TO G.J.GARDNER HOMES                       QBCC 1257143             Typical Tie-Down Details                                                                                          26.03.21                                                               BUILDER SIGNED: .............................   DATE: ..........
Log in to download the original file

18 Yatama Drv - WD 15.04.21 (1)- Shed Plotted.pdf · 2.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.