Original source · versioned page text
Callaghan and Toth IWMP Report revised
ecoAID®
Technical Data
Chamber Volume (m3) 0.516m3
Min Installed Storage
(incl. 150mm rock bedding 0.822m3
and cover layer) ps = 0.40
Chamber Physical Length 1.00m
D
Chamber Installed Length 0.97m
B
Chamber Width 1.16m
Chamber Height 0.68m
Min Installed Storage Height
(incl. 150mm rock bedding 0.98m
and cover layer)
LEGEND:
A. ecoAID® EC1000 Chamber
B. ecoAID® EC1000 End Cap
C. bidim® A24 non-woven geotextile surround
D. bidim® Filter Wrap (over C-A-R)
E. 40kN Woven geotextile (along base of C-A-R)
1. Finished surface layer as specified by design engineer
2. Backfill material as specified by design engineer
3. 20-50mm Ø drainage rock/RCC/scoria
4. Subgrade
5. 150mm – 625mm Ø (OD) inlet pipe
6. Connecting pipe network
min < H > max
7. Manhole inlet structure
8. 100mm – 150mm Ø optional inspection/ventilation pipe
9. 100 – 150mm Ø optional lateral equalisation pipes
* The rock component provides additional storage and it's porosity
(typically 40%) is used when calculating the tanks overall storage
capacity.
* The ecoAID® system can be installed in a single or double layer
configuration.
* Please refer to our ecoAID® standard detail drawings for more
information.
ecoAID® COVER REQUIREMENTS
NOT SUBJECT TO Hmin Hmax
VEHICLE LOADING
eg - Public open space 300 2500
SUBJECT TO VEHICLE LOADING
not in roadway 450 2500
in sealed roadway 600 2500
under unsealed roadway 750 2500
minimum required values maximum allowable values