“ ih

ken hicks

Land Development

9. Provide a plan of the building and other structures indicating the exact location of the
sewer on the site and demonstrate that the proposed structures comply with the setbacks
to sewer required by Council's “Existing Services Code". If it is proposed to relocate the
sewer please provide a plan of the alternative, as plans currently indicate a pool over the
top of the existing sewer and buildings within the required setback.

Response

The existing sewer is wholly contained within proposed sewer easement A on SP194337 (copy
attached in Appendix C). This survey plan has been prepared in accordance with conditions of
development permit 05/1917. The proposed development has been amended to relocate all
building and structures clear of this sewer easement as required by the Existing Services Code.

10. Provide a plan indicating the proposed access arrangement from David Low Way in more
detail.

Response

A plan indicating the proposed access arrangement from David Low Way will be provided as
part of an Operational Works application. It is envisaged that the driveway will provide for left-
inleft-out access.

11. Justify why more on site rainwater storage (3000 litres proposed) is not required given that
the units are for rental accommodation and will require water usage, although to a lesser
extent than a normal dwelling unit. Officers believe that the motel units are not exempt
from Schedule 8 and require some rainwater reuse capacity.

Response

Schedule 8 specifically refers to rainwater tanks for dwelling units. The proposal only includes
one dwelling unit, together with 12 accommodation units. The applicant is however prepared to
provide a reasonable rainwater tank provision for the development. A 3000 litre rainwater tank
is required for a single dwelling house which would have a roof area in the order of 200-250m*.
The proposed motel has a roof area of 565m?. In this regard provision of rainwater tanks having
a storage capacity of 9000 litres is considered reasonable in this instance.

12. Provide evidence that the queuing distance to the visitor spaces complies with
AS2890. 1:2004 - Parking Facilities Part 1 Off-street Car Parking.

Response

Correspondence from TTM traffic consultants confirming the adequacy of the queuing distance
is attached in Appendix D.

Used in these records

About this file

File size
2.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

06_2552 - Response to information request dated 08_01_07 [As Published].pdf · 2.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.