Council archive · source document
Revised Engineering Plans · MCU24/0153.01
Plans and drawings: the text below has words only, no drawings.
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
S
SERVICES NOTES
S
1. UNLESS OTHERWISE STIPULATED BY TELECOMMUNICATIONS LEGISLATION AT THE TIME OF CONSTRUCTION,
THE DEVELOPMENT MUST BE PROVIDED WITH ALL NECESSARY CONDUITS, PITS AND PIPES TO ACCOMMODATE
THE FUTURE CONNECTION OF OPTIC FIBRE TECHNOLOGY TELECOMMUNICATIONS.
>
2. CERTIFICATION MUST BE SUBMITTED TO COUNCIL FROM ALL RELEVANT SERVICE PROVIDERS (ENERGEX,
S
NBN AND UNITYWATER) WHICH CERTIFIES THAT THE DEVELOPMENT HAS MET THE REQUIREMENTS OF THIS
DECISION NOTICE AND ALL APPLICABLE LEGISLATION AT THE TIME OF CONSTRUCTION.
>
GEOTECHNICAL NOTES
1. ALL WORKS MUST BE CARRIED OUT IN ACCORDANCE WITH THE RECOMMENDATIONS CONTAINED IN THE
S
PROPOSED UNIT DEVELOPMENT REPORT PREPARED BY TECTONIC ON THE 30th OF SEPTEMBER 2024, REF.
>
24265-001-REV0.
EARTHWORKS AND RETAINING WALLS NOTES
>
1. ALL EARTHWORKS AND ASSOCIATED BATTERS/RETAINING STRUCTURES, BOTH ABOVE AND BELOW GROUND
S
RETAINING WALL LEVEL, BOTH TEMPORARY AND PERMANENT, MUST BE CONTAINED ENTIRELY WITHIN THE SUBJECT SITE
BY OTHERS UNLESS WRITTEN PERMISSION FROM THE RESPECTIVE LANDOWNER(S) IS PROVIDED TO COUNCIL. ALL
EARTHWORKS MUST BE UNDERTAKEN IN ACCORDANCE WITH THE PROVISIONS OF AUSTRALIAN STANDARD
>
AS3798: GUIDELINES ON EARTHWORKS FOR COMMERCIAL AND RESIDENTIAL DEVELOPMENTS.
2. WHERE THE DEVELOPMENT INVOLVES EXCAVATION OR FILLING OVER, OR ADJACENT TO, DRAINAGE, WATER
S
SUPPLY OR SEWERAGE INFRASTRUCTURE, ALL ACCESS CHAMBER SURFACE LEVELS MUST BE ADJUSTED TO
>
PROVIDE A FREEBOARD OF 100MM ABOVE THE FINISHED GROUND SURFACE LEVEL.
3. ALL RETAINING WALLS MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE PLANNING
TOW = 46.15 m SCHEME AND MUST BE CERTIFIED BY AN RPEQ WHERE EXCEEDING 1.0M IN HEIGHT. ALL RETAINING WALLS
>
TOW = 46.40 m BOW = 42.95 m THAT ARE PUBLICLY ACCESSIBLE AND EXCEED 1.0M IN HEIGHT MUST BE FITTED WITH A COMMERCIAL GRADE
S
BOW = 42.95 m H = 3.20 m SAFETY FENCE.
H = 3.45 m
>
LOT CP
S
D
NOTE:
02
>
TOW = 46.15 m GTP689
2
BOW = 42.95 m EXCEPT WHERE NOTED ON PLAN AND ASSOCIATED DESIGN DRAWINGS,
LOT CP H = 3.20 m ALL IN-GROUND SERVICES WITHIN THE PROPERTY BOUNDARY INCLUDING
>
TOW = 47.06 m
S
BUP102822 BOW = 42.95 m
BUT NOT LIMITED TO: STORMWATER DRAINAGE, SEWERAGE, WATER, GAS,
ELECTRICAL AND COMMUNICATIONS TO BE SAFELY BE DISCONNECTED,
H = 4.11 m
REMOVED FROM SITE AND CAPPED OFF AT SITE BOUNDARY. CONTRACTOR
>
TO ARRANGE ALL NECESSARY APPLICATIONS AND PERMITS WITH THE
S
TOW = 46.15 m RELEVANT AUTHORITIES. SERVICES TO BE CAPPED IN ACCORDANCE WITH
BOW = 42.95 m
>
RELEVANT SERVICE PROVIDER SPECIFICATIONS AND STANDARD DETAILS
H = 3.20 m
LEGEND:
S
CONCRETE PILE FOOTINGS
E
TO BE CONFIRMED WITH CL E EXISTING CONTOURS
I CY RAG
42.
STRUCTURAL ENGINEER B O
>
ST
0
42.
TOW = 46.15 m
2
EXISTING BUILDING
42.
S
BOW = 42.95 m
4
42.
TOW = 47.40 m FT
6
LI AFT H = 3.20 m EXISTING KERB AND CHANNEL
BOW = 40.70 m S H
H = 6.70 m
EXISTING FENCE
S
T EXISTING TELSTRA
10
TOW = 47.50 m S S OE EXISTING OVERHEAD ELECTRICAL
BOW = 40.70 m
9
40.
H = 6.80 m .96 W EXISTING WATER
41.
8
43
41.
0
41.
2
.63
41.
S
4
43 EXISTING SEWER
41.
6
C2
42.
8
42.
02
8
0
42.
2
EXISTING TELSTRA PIT
42.
4
42.
6
8
WM EXISTING WATER METER
7
XX.X EARTHWORKS CONTOURS
TOW = 48.70 m TOW = 46.70 m
BOW = 42.95 m ADJACENT BOUNDARY
BOW = 40.70 m 5&
6
H = 8.00 m H = 3.75 m
PROPOSED BOUNDARY
E NT
M PROPOSED STORMWATER PIPE
3&
4
40.
A SE
8
B PROPOSED STORMWATER PIT
41.
0
RETAINING WALL
2
1& 41.
TOW = 49.92 m 2
> > > PROPOSED SWALE
BOW = 40.70 m 41.
H = 9.92 m 4 PROPOSED CONCRETE PILE FOOTINGS
41.
W AY (INDICATIVE ONLY)
6 H
P AT TOW = 47.31 m
8
41. BOW = 42.95 m
H = 4.36 m
0
42. EARTHWORKS VOLUMES
EARTHWORKS VOLUMES FROM EXISTING
42. CONCRETE PILE FOOTINGS
W 2 SURFACE TO BOTTOM OF EXCAVATION FOR
TO BE CONFIRMED WITH
BASEMENT, CARSTACKERS & LIFT WELL
42. STRUCTURAL ENGINEER
CUT = -2428 m³
4
FILL = +158m³
W
42.
6
BALANCE = - 2270 m³
W LOT CP CUT/FILL DEPTH RANGE LEGEND
EL
TOW = 47.76 m
BOW = 42.95 m SP193676
AN
LOWER VALUE (m) UPPER VALUE (m) COLOUR
H = 4.81 m
DW
<-9 -8
A
-8 -7
ST
-7 -6
RE
W
TOW = 49.89 m -6 -5
ET
BOW = 42.95 m -5 -4
H = 6.94 m
W
-4 -3
-3 -2
-2 -1
W -1 0
B
1 0 1
02
1 >2
W
FOR CONSTRUCTION A
1
02
.33
49
FD
.53
49
---- ---- ---- ---- ---- North Point Approved Project Address Sheet Title
---- ---- ---- ---- ----
EOIN WHITMORE
51 ELANDA STREET, BALEIA BULK EARTHWORKS LAYOUT PLAN
N
---- ---- ---- ---- ---- 31423 03/06/2026
---- ---- ---- ---- ---- For and on behalf of RECOR Pty Ltd.
03 07/10/26 ISSUED FOR CONSTRUCTION FP AY Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
02 03/06/26 ISSUED FOR CONSTRUCTION FP AY SCALE
1 0 1 2 3 4 5
(metres) www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE
1 : 100 (FULL SIZE) Project Number Sheet Number Revision
01 25/02/26 ISSUED FOR CONSTRUCTION DP AY COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
in the revision description. 20240127 C020 03
See the original
The page text is free to read. Viewing or downloading an original file needs an account.