EXTERNAL FOOTPATH RAMP AND STAIRS NOTES:
1. THE EXTERNAL FOOTPATH, RAMP AND STAIRS SHALL BE
CONSTRUCTED IN ACCORDANCE WITH AUSTRALIAN STANDARDS AS
1428.1-2001, AS1428.2-1992, AND THE PROPOSED DESIGN.
2. WARNING TACTILE INDICATORS (TGSIs) ARE TO BE PLACED AT THE
TOP OF ALL RAMPS AND STAIRS AND AT THE TOP AND BOTTOM OF
ALL RAMPS AND STAIRS WHERE THE LANDING WIDTH EXCEEDS 3.0m
WIDE. TACTILE INDICATORS ARE TO BE PLACED IN ACCORDANCE
WITH AS1428.4 - 2009.
3. CAMBER AND CROSSFALL MUST NOT EXCEED 1:40 IN ACCORDANCE
WITH AS1428.1-2001
4. STAIRS AND RAMPS ARE TO BE SLIP RESISTANT SURFACES IN
ACCORDANCE WITH AS 4586-2013 AND HB 197:1999
BOUNDARY
PROPERTY
FOOTPATH CONCRETE TO
BE IN ACCORDANCE WITH
IPWEA STD DRG RS-065
PROPOSED TYPE 2 HANDRAIL IN ACCORDANCE WITH IPWEA STD
DRG. GS-044 OR OTHER SIMILAR PRODUCT NOMINATED BY
ARCHITECT AND APPROVED BY COUNCIL AND TO COMPLY WITH
CLAUSE 10 OF AS 1428.2-1992 ACCESS AND MOBILITY
SHOWN INDICATIVELY ONLY.
STAIRS TO BE
DESIGNED BY OTHERS
STAIRS TO BE
DESIGNED BY OTHERS
TIE IN NEATLY WITH
EXISTING FOOTPATH
VIP49.207
VIP49.208
VIP48.013
VIP48.013
VIP46.886
VIP46.886
VIP45.758
VIP45.758
VIP45.051
VIP45.051
VIP44.345
VIP44.343
VIP43.318
VIP43.151
DATUM R.L. 42.00
GRADE 0.03 % -10.37 % 0.00 % -12.53 % 0.00 % -12.53 % 0.00 % -75.17 % 0.00 % -78.53 % -0.09 % -72.71 %-12.24 %
LENGTH
HORIZONTAL ALIMNT
ARC LENGTHS TAN 3.086 TAN 12.719 TAN 10.300 TAN 8.901 TAN 4.161 TAN 3.477 TAN 3.751
49.207
49.208
48.491
48.013
48.013
47.488
46.886
46.886
46.385
45.758
45.758
45.051
45.051
45.051
44.345
44.343
43.318
43.151
DESIGN CENTRELINE
40.000
40.404
41.304
43.623
45.033
46.395
20.000
24.805
26.005
30.000
35.006
37.143
38.084
10.000
14.605
15.805
0.000
3.086
CHAINAGE
1.0 0 1.0 2.0
VERTICAL SCALE (metres)
1 : 50 (FULL SIZE)
1 0 1 2 3 4 5
HORIZONTAL SCALE (metres)
1 : 100 (FULL SIZE)
FOR CONSTRUCTION
---- ---- ---- ---- ---- North Point Approved Project Address Sheet Title
---- ---- ---- ---- ----
EOIN WHITMORE
51 ELANDA STREET, BALEIA FOOTPATH LONGITUDINAL SECTION
---- ---- ---- ---- ---- 31423 03/06/2026
---- ---- ---- ---- ---- For and on behalf of RECOR Pty Ltd.
---- ---- ---- ---- ---- Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
02 03/06/26 ISSUED FOR CONSTRUCTION FP AY www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE
01 25/02/26 ISSUED FOR CONSTRUCTION DP AY COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
in the revision description. 20240127 C015 02
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.