Table Error! No text of specified style in document.-1 — For All Residential Uses

Cre Ta
Specific Outcomes

   

Effects of use

column 2
Probable solutions (if code assessabie)

ore
Compliance

 

Electricity supply infrastructure

ot The development does not adversely impact on existing or
future electricity supply infrastructure;

AND

02 All uses and works maintain an adequate safe distance from
electrical infrastructure including substations, overhead powerlines,
power poles and transformers.

Environmentally Sustainable Building Design

$1.1 No solution provided

$2.1 Development for uses adjacent to or within 50m of an

existing electricity substation incorporates noise attenuation

measures to mitigate noise impacts;

AND

$2.2 Buildings and structures (including swimming pools, sheds,

tennis courts or outbuildings) are not constructed under

overhead electricity transmission lines, or within electricity

easements;

AND

$2.3 A minimum separation distance is maintained from the

electricity transmission line to the closest boundary of habitable

buildings and child activity areas, as follows—

a) 20m for transmission lines up to 132kV;

bd) 30m for transmission lines between 133kV and 275kV;
and

Lo

40m for transmission lines greater than 275kV.

Complies

 

Hot Water Systems”

O3 —_-Hot water systems are installed and operated to support the
efficient use of natura! resources and minimise consequent pollution
such as greenhouse gas emissions.

$3.1 All hot water systems installed are—
a) solar systems; or

b) electric heat pump systems; or

c) natural gas or LPG systems; or

d) any combination of a), b) or c).

Conditions may be imposed in this regard.

 

Water supply and conservation
O04 On-site water storage is designed and operated to support
the efficient use of water;

AND

O05 On-site water storage is adequate for occupants every day
use and fire fighting purposes.

$4.1 If in a designated rainwater tank area as identified in Map 1
of Schedule 8, residential uses that qualify as class 1A or 18
structures under the Building Code of Australia have a rainwater
tank or tanks in accordance with Schedule 8.

AND

$5.1 Where not in a water service area a rainwater tank of a
minimum of 60,000 litres is provided for each dwelling unit, with
the exception of Multiple Housing Type 1.

Conditions may be imposed in this regard.

 

Erosion and sediment control
O6 Development does not cause erosion or result in transport of
sediments off-site.

 

No solution provided.

 

 

Conditions may be imposed in this regard.

 

‘This does not apply to buildings which qualify as Class 1A or 1B structures under the Building code of Australia

Residential Uses Code - 00868 Oak Investment Holdings Pty Ltd

 

Used in these records

About this file

File size
6.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2174 - MCU - Multiple Housing Type 4 - Conventional 5 Units [As Published].pdf · 6.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.