g f e d c b a
property boundary
property boundary
rnd01
con02
bal01 bal01
roof rnd01
RL24.100 con02
con02
3100
bal01
first floor
RL21.000
ground ceiling con02
RL20.460 con02 con02 con02
rnd01
til04 sliding screens gls01
con02
3500
bal01
ground level
RL17.500
con02
bal01 gls01
4000
con03
pool
lower ground rnd01
RL13.500 til01
lower ground gym
RL12.300
bal01 frameless glass balustrade
con02 class 1/2 off-form concrete NOOSA COUNCIL
con03 board-form concrete Noosa Council notation
gls01 clear low e door/window glass
ENDORSED PLANS
Til04 = Black Tile.
rnd01 course render (tyrolean UNO) MCU24/0094 18 JUNE 2025
til01 tile type 01
til04 tile type 04
general notes general items legend
RL 60.200 spot level L1 (level) window code. refer to window component code. 20 step down code. note step line
1. all works to be carried out in accordance with the general construction 6. levels and services locations for civil works may vary from those shown -
notes in coversheets of this package. verify all levels and services locations prior to commencement of tos = top of step w01 (window ref) elevations + door/window dp01 (refer material code for similar) occurs on low side of level
2. all works to be carried out in accordance with the DA (if required) and BA construction. bos = bottom of step hardware schedules low lvl low lvl + 20 mm change
including drawings & conditions. 7. concrete profile and blockwork setout is provided on 220 (series) of RL = lvl at point (AHD typ)
3. handrails are required to all stairways where a change of level of drawings, refer to these for setout. licensed surveyor to establish grids.
RL xx.xxx top of wall (surface) level door/gate code. refer to window ceiling code hose cock. refer serivces
1000mm or greater occurs as per BCA 2013 Part 3.9.2.4. where discrepancies occur the 220 series drawings are to take L1 (level)
d01 elevations + door/window 2700 * heights are relative to assocaited schedule. client to confirm
4. where boundary locations are not clear, the builder shall arrange for precedent. (door/gate ref) height* hc
hardware schedules Ipb01 finish** finished floor locations
survey to locate the boundaries and complete an identification survey
* refer finishes schedule
prior to setting out the new work. SSL xx.xxx structural slab level
5. contours shown are existing and do not represent finished levels.
material code. refer finishes J0.1 joinery code. refer to cabinetry (cos) check on site
Ipb01 Ipb01 schedule (typical). elevations on 820 (series) and (mir) mirrored detail
FFL xx.xxx finished floor level (refer also to sanitary/ applicances/
level joinery
details on 830 (series) drawings (sim) similar detail
reference
lighting/services as appropriate) (part) partial detial
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0427
NM
RW
A
B
30/05/24
17/06/24
SD Client Issue 02
SD Client Issue 03
33 Ross Crescent, Ross Crescent Family building elevations SD 300.01 D SCALE As
indicated
Sunshine Beach Trust
A3
NM C 05/07/24 DA Issue eastern elevation
NM D 17/06/25 Amended DA schematic design
1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
[OCR of page images]
property boundary
first floor
ground ceiling
RL20.460
ground level
W_RL17.500
lower ground
W_R113.500
lower ground gym
V RL12.300
frameless glass balustrade
class 1/2 off-form concrete
board-form concrete
clear low e door/window glass
course render (tyrolean UNO)
tile type 01
tile type 04
Noosa Council notation
Til04 = Black Tile.
property boundary
NOOSA COUNCIL
ENDORSED PLANS
MCU24/0094 18 JUNE 2025
general notes
general items legend
all works to be carried out in accordance with the general construction
notes in coversheets of this package
all works to be carried out in accordance with the DA (if required) and BA
including drawings & conditions.
handrails are required to all stairways where a change of level of
41000mm or greater occurs as per BCA 2013 Part 3.9.2.4
where boundary locations are not clear, the builder shall arrange for
survey to locate the boundaries and complete an identification survey
prior to setting out the new work.
contours shown are existing and do not represent finished levels.
levels and services locations for civil works may vary from those shown -
verify all levels and services locations prior to commencement of
construction.
conerete profile and blockwork setout is provided on 220 (series) of
drawings, refer to these for setout. licensed surveyor to establish grids.
where discrepancies occur the 220 series drawings are to take
precedent.
-¢>- RL60.200 | spot evel
tos = top of step
| bos = bottom of step
| top of wall (surface) level
ae slab level
“Thnished oor level
[WOT] oon
(AD (ved
{GOT (cage
| window code. refer to window
elevations + dooriwindow
| hardware schedules
doorlgate code. refer to window
elevations + dooriwindow
| hardware schedules
| schedule (ypical).
(efer also to sanitary! applicances!
|lahtingservices as appropiate)
| component code.
| (refer material code for similar)
ceiling code
* heights are relative to assocaited
finished floor
* refer finishes schedule
_ lS code. refer to cabinetry
tev tL jinry
| elevations on 820 (series) and
tfrnce details on 830 (series) drawings
20 | step down code. note step line
occurs on low side of level
tov Fowitsziem | change
hose cock. refer serives
| schedule. client to confirm
| locations
check on site
mirrored detail
similar detail
|Patal deta
DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV Pelton irees
shaun lockyerarchitects eas 33 Ross Crescent, __—-—Ross Crescent Family _ building elevations s 300 6p
Sunshine Beach Trust eastern elevation .
www.lockyerarchitects.com.au . O07 3257 7288 05/07/24 DA Issue
schematic design A3
1:1@
nominated architect: Shaun Lockyer 3455 QLD . 9377 NSW 17/06/25 Amended DA’
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.