REFER: PBA11/0095 Referral Agency Response - roof top terrace - 34 Belmore Tce SUNSHINE BEACH
Compliance Certificate for building Design or
Specification 15
NOTE This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
Building Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether
building work complies with the BCA or a provision of the QDC. A building certifier (Class B) can
not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description Street address Include no., street, suburb/ locality & postcode
This section need only be completed if 34 Belmore Terrace
details of street address and property
description are applicable. Sunshine Beach Postcode 4567
EG. In the case of (standardigeneric)
Lot & plan details (attach list if necessary)
pool designishell manufacture and/or
patio and carport systems this section
may not be applicable.
In which local government area is the land situated?
The description must identify all land the Sunshine Coast Regional Council
subject of the application.
The lot & plan details (eg. SP ! RP) are
shown on title documents or a rates notice.
if the plan is not registered by title, provide
previous lot and plan details
2. Description of components certified
Clearly describe the extent of work covered by
Proposed roof top terrace consisting of tiled timber framed deck built over.
this certificate, e.g. all structural aspects of the
steel roof beams,
Items not certified: Windows and Doors, Balustrading, Pool Fencing
Pre-fabricated Roof Trusses, Bracing & Girder Truss Support
Roof sheeting or Tiles
3. Basis of certification
• AS 1170.1 Dead and Live Loads and load Combinations
Detail the basis for giving the certificate and the
extent to which tests, specifications, rules. • AS 4055 Wind Loads for Houses
standards, codes of practice and other • AS 1720 Timber Structures
publications, were relied upon. • AS 1684.2 Residential Timber Framed Construction
• AS 2870 Residential Slabs and Footings
• AS 3600 Concrete Structures.
Loading Criteria:
Wind Loading: Region: B Terrain Cat: 2.5 Topographic Class: TI
Shielding: PS Design Wind Classification: N3
Floor Loading: Internal: 1.5 kPa Balconies: 3.0 kPa
LOCAL GOVERNMENT USE ONLY
Date receN,,d Referarce iiumberts Approved form IS
Version 2 01106
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
REFER: PBA11/0095 Referral Agency Response - roof top terrace - 34 Belmore Tce SUNSHINE BEACHRelated documentApplication case desk ↗
REFER: PBA11/0095 Referral Agency Response - roof top terrace - 34 Belmore Tce SUNSHINE BEACHRelated documentApplication case desk ↗
About this file
- File size
- 3.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.