Original source · versioned page text
MCU16/0079 Appendix D - Stormwater and Sewer Layout Plan
LEGEND
EXISTING PROPERTY BOUNDARY
PELICAN STREET EXISTING CONTOUR - MAJOR
N
EXISTING CONTOUR - MINOR
EXISTING BUILDING
EXISTING KERB AND CHANNEL
N
N
N
SW
N
EXISTING STORMWATER DRAINAGE
N
N
N
N
N
N
N
N N
N
N
N
N
N
N
N
S
N
EXISTING SEWER
W EXISTING WATER
EXISTING ELECTRICAL OVERHEAD
N
HV EXISTING ELECTRICAL HIGH VOLTAGE
E EXISTING ELECTRICAL LOW VOLTAGE
RW
T EXISTING COMMUNICATIONS
G EXISTING GASLINE
X X X X X X X X ABANDON EXISTING SERVICE
SW SW SW SW SW SW SW SW
PROPERTY BOUNDARY
RW
EASEMENT BOUNDARY
RW RW RW RW RW RW BUILDING
KERB AND CHANNEL
SW
KERB
SW SW STORMWATER DRAINAGE
RW RW ROOFWATER DRAINAGE
SEWER
SW
W W WATER MAIN
CW CW PRIVATE COLD WATER SUPPLY
I I SEDIMENT FENCE
I
I
I
EXISTING SURFACE LEVEL
SW
1
DOONELLA STREET
RL1.234 PROPOSED SURFACE LEVEL
POINCIANA AVENUE
SW
USIL 3.904
DSIL 3.571
L = 60.00
GRADE 1:180
SW SW SW SW SW SW SW SW SW SW
2 0.60
1 SEWER LINE 1
SW
USIL 3.551
EXISTING SEWER TO BE ABANDONED DSIL 3.520
EXISTING SEWER TO BE ABANDONED X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X L = 5.600
X X
X
X
GRADE 1:180
X
SW
X
X
X
SEWER LINE 1
X
S S
X X X X X X X
10
X
X
X
SW
X
X
1.125
EXISTING SEWER TO BE ABANDONED
X
SW
USIL 4.161 X
X
X
X
DSIL 3.924
SW
L = 23.60
X
GRADE 1:100
EXISTING BUILDING
X
X
SW
X
N
0.60
NN
SW
EXISTING BUILDING
SW
3
N
N
SW
N
N
N
EU
MEMORIAL AVENUE
N
EU
LAYOUT PLAN
SCALE 1:200
CLIENT: SCALE: 1:200 DRAWN: JC PROJECT: JOB No.:
E: [email protected]
TEWANTIN - NOOSA RSL
16144
A: PO Box 26, Carina
SHEET SIZE: A1 DESIGN: AvT
Ph: (07) 3172 8334
1 MEMORIAL AVE, TEWANTIN QLD 4565
PLOTTED: 14.07.2016
W: vtce.com.au
DATUM: AHD CHECKED: AvT
QLD 4152
COPYRIGHT: THIS DOCUMENT IS AND SHALL REMAIN APPROVED: DRAWING TITLE: DRAWING No.: REV.:
0 2 4 6 8 10 B 14.07.16 GENERAL REVISIONS JC AvT THE PROPERTY OF vT CONSULTING ENGINEERS. THIS
SEWER RETICULATION LAYOUT
B
DOCUMENT MAY ONLY BE USED FOR THE PURPOSE
SCALE 1:200
A 08.07.16 PRELIMINARY ISSUE JC AvT FOR WHICH IT WAS COMMISSIONED AND IN
ACCORDANCE WITH THE TERMS OF ENGAGEMENT.
UNAUTHORISED USE OF THIS DOCUMENT IN ANY
P003
REV. DATE: AMENDMENT: BY: APP: NOT FOR CONSTRUCTION