Input Length of excavation: |20 | metres Width of excavation | 18 | metres Drawdown required: | 18 | metres Aquifer thickness”) | 10 | metres Hydraulic conductivity: lo 0000949 | metres/second Calculate Results Effective pumping radius, Re: 11 metres Cone of depression radius, Ro : 53 metres litres/second oO Total pumping rate: Pumping time required: 44 hours