Council archive · source document
Delegated Report - Code - Planning MCU22 0145 [As Published] · MCU22/0145
Front fence/walls
• Setback 1m (average) + stepping @ 5m 1.2m + step
@3m
Basements access width 6 metres max 5.2
Landscaped open space 40% > 40%
Soft landscaping 60% of landscaping is to be soft > 60%
Landscaping Setbacks 2m to car parking 6m
Private Open Space 25m² min at ground and 12m2 above Exceeds
ground level requirement
Carparking 5 covered min 6 covered
Boundary Setbacks
Acceptable Outcome AO9.1(a) of the High Density Residential Zone Code requires the frontage of
building and structures to be setback:
(a) first and second storeys— 6 metres
(b) third storey and thereafter—10 metres
The third storey (denoted as “Level 3” in the submitted plans) of the proposal is setback 6 metres
from the frontage to Henderson Street and is non-compliant with this Acceptable Outcome. The
relevant Performance Outcomes generally requires building and structures to:
(a) provide a high level of amenity to users of the subject site and adjoining premises,
including provision of visual and acoustic privacy;
(b) not unreasonably obstruct views or cause overlooking of private open space or
habitable areas of adjoining premises;
(f) be consistent with the predominant character of the surrounding area; and
The predominant character of the surrounding area is high density residential, with a majority of
the adjoining parcels containing multiple dwellings. These dwellings generally comply with the
Acceptable Outcome AO9.1, and the third storeys of these buildings are also stepped to achieve
the 10 metres from the frontage setback requirements.
It is noted however that some of these dwellings contain balcony areas which encroach into the
setbacks, however, these areas are unenclosed which helps reduce the bulk of the buildings.
The development proposes two terraces on the third storey with a combined area of 54.72m2. The
southern balcony includes rendered concrete walls, retractable shutters and privacy screens that
have the ability to be fully enclosed spaces.
The applicant submits that the proposal achieves the Performance Outcome PO9 as:
• The front blade is an architectural feature that is unlikely to be seen from neighbouring
properties and adds visual interest to the building design.
• The blade wall provides separation and privacy between the 2 dwellings’ balconies.
• The wall and pool are located to the front of the building and cannot be seen from the rear
neighbouring properties.
• Does not obstruct views as the neighbouring property to the west faces the other direction
and the subject site views over the roof of the eastern property.
Page 8 of 28
Document Set ID: 22322758
Version: 7, Version Date: 22/08/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - Planning MCU22 0145 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.