Appendix C - Engineering File Note

of 2
File note

File number 25 Tulip St, Cooroy

Subject          Unitywater Sewer and siting of Lot 2

Author           Jaro Bauleka



Date             10 November 2025

   •         Unitywater sewer asset is located at the rear of the existing dwelling with an
             average grade of 2.6% fall from west to east (based on approximate of 88m from
             mapping).




        Interpolating the invert level of the sewer within the centre of Lot 2 yields a value of RL
         111.91m.
        Allowing the following to set the dwelling’s indicative Finished Surface Level (FSL)



                                                                          Auxilium Consulting Pty Ltd
                                                                                 ABN 84 639 195 092
                                                                                     Bli Bli Qld 4560

Log in to download the original (Appendix C - Engineering File Note.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 1 page

Page 2

                                       -2-




   o   Invert of house drain is 500mm below design FSL
   o   Allowing 750mm cover for the existing 150mm dia sewer within a lot subjected
       to traffic

The dwelling for Lot 2 will need to be at least RL 112.41m for the house connection,
with a surface level to provide for vehicle traffic of RL 112.81m.