Original source · versioned page text
Traffic Engineering Report
Design Aspect Minimum Council Standard Proposed Provision Compliance
(AS2890.1)
− Door opening 2.4m 2.6m Compliant
Enclosed Double Garage
− Length 5.4m 5.4m & 6m Compliant
− Width 5.4m 5.4m Compliant
− Door opening 4.8m 5.1m Compliant
Aisle Width:
− Parking aisle 5.5m + 0.3m clearance (1 side) 6.2m Compliant
− Circulation aisle 5.5m + 0.6m clearances 6.5m Compliant
Parking envelope clearance - 0.25m into bay within 0.3m & 0.2m into bay within 0.9m Compliant
Column intrusion 0.2m into bay within 1.2m of of front of bay
front of bay
Parking envelope clearance – space Space 0.3m clear of wall Space 0.3m clear of wall Compliant
adjacent to wall
Parking envelope clearance - Located between 0.75m and Located between 0.75m Compliant
Column adjacent to bay 1.75m of aisle and 0.85m of aisle
Maximum Gradient:
− PWD parking bay 1:40 (2.5%) Generally Flat Compliant
− Parking bay 1:20 (5.0%) Generally Flat Compliant
− Parking aisle 1:16 (6.25%) Generally Flat Compliant
Height Clearance
− General Min. 2.2m (2.3m PWD) 2.2m min Compliant
Parking Aisle Extension 1m beyond last bay 1m beyond last bay Compliant
The proposed parking layout arrangements comply with all Council requirements and are, therefore,
considered suitable.
Site: 99, 101 & 105 Eumundi Noosa Road, Noosaville 13
Reference: 20BRT0474
See the original