Council archive · source document
14717_1 Coral Sea Court, Sunshine Beach - Technical Note_DRAFT · OPW14/0352
Attached to the e-mail OPW14/0352 Non - Standard Driveway Crossover at 1 Coral Sea Court Sunshine Beach. Engineers Report & Receipt of Payment.
Technical Note Address: 1 Coral Sea Court, Sunshine Beach Client: John & Jane Turner 1. Background Mr and Mrs Turner propose a driveway, to serve the above property, to be located on Whale Drive, as opposed to Coral Sea Court. Whale Drive is a local road, with a speed limit of 50km/hr and a very low traffic volume. The road is approximately 6.0m in width and has a longitudinal gradient of 11.7% at the location of the proposed driveway access. Tod Consulting were requested to undertake an engineering review of the proposed driveway location, in support of an application to Noosa Council. Our assessment has included: Conversation with Mr Turner; Conversation with Mark Lewis of Noosa Council; Review of Layout Drawing prepared by Design to Detail (Drawing No. 1424 attached). Site visit and determination of sight distances; A review of the proposed driveway location based on current standards; and Preparation of this Technical Note to summarise our findings. 2. Assessment of Proposed Driveway We have assessed the proposed driveway location on Whale Drive against the requirements of AS2890 – Parking Facilities – Part 1: Off-Street Car Parking and summarise our findings below. a) AS2890.1 - Section 3.2.3 – Access Driveway Width Table 1.1 classifies domestic parking as User Class 1A. Based on User Class 1A, Local Road and less than 25 parking spaces, reference to Table 3.1 categorises this access facility as Category 1. Table 2.3 states a Category 1 access driveway is to be a minimum of 3.0m in width, which the owner can comply with. b) AS2890.1 - Section 3.2.3 – Access Driveway Location Section 3.2.3 of this code states a driveway should not be located within 6.0m of the tangent point of an intersection street. The proposed driveway would be located approximately on the tangent point and therefore does not comply with this requirement. 1 14717_1 Coral Sea Court, Sunshine Beach - Technical Note_DRAFT
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 3 pages
Page 2
c) AS2890.1 - Section 3.2.4 – Sight Distance at Access Driveway Exits
The code states that access driveways are to be located in a manner that provides adequate entering
sight distance for traffic exiting the property to view traffic on the frontage road i.e. Whale Drive.
The driver sight distances are measured, in each direction, from a point 2.5m from the road edge.
When checking the sight distances, the driver’s eye height and the height of the object (approaching
vehicle) were taken to be 1.15m above the road surface.
Based on a posted speed limit of 50km/hr on Whale Drive, a domestic property access requires a
distance (Y) along the frontage road of 40m. When looking right the sight line is measured to the
edge of the frontage road. When looking left the sight line is measured to the centre of the road.
Tod Consulting have undertaken an inspection of the property and undertaken a physical check of the
available sightlines. A summary of the sight distances are tabulated below.
AS2890.1 - Section 3.2.4 Requirements Actual Sightlines available
40m (both directions) 70m to the right
60m to the left
It is evident from the above that compliant sight distances can be achieved in both directions.
These actual sight lines can be seen in Photos 1 and 2.
Photo 1: 70m Sightline to the Right (Silver Gull Court intersection located 45m away)
2
14717_1 Coral Sea Court, Sunshine Beach - Technical Note_DRAFT
Page 3
Photo 2: 60m Sightline to the Left (Lampost located 60m away)
It should be noted that there is existing yellow no standing line markings, on both sides of the road, for
a considerable distance in each direction. This therefore prevents vehicles parking on-street and
obstructing the available sight lines.
It should be noted it is essential that no physical obstructions are erected within the sight line triangles
and existing vegetation is maintained or trimmed to ensure the future safe operation of this driveway
access.
3. Safety
a) Proximity to Intersection
It should be noted that Coral Sea Court is a no through road and there would be a very low volume of
traffic utilising the existing intersection.
Although the proposed driveway is located within the desireable 6.0m offset from the tangent point, it
could be considered beneficial that it is located on the through road of the intersection. Therefore,
approaching vehicles, from either direction have more than adequate sight lines to the proposed
driveway.
If the driveway was located on Coral Sea Court a vehicle could turn left from Whale Drive and have
very little advance warning or sight distance.
The proposed driveway location is on the approach side for vehicles on Whale Drive turning left into
Coral Sea Court. As such vehicles exiting from Coral Sea Court will not conflict with vehicles entering
and exiting the driveway.
3
14717_1 Coral Sea Court, Sunshine Beach - Technical Note_DRAFT
Page 4
b) Vehicle Turnaround
Although not required, the owner has agreed to provide a turnaround within the property to avoid the
need to reverse onto Whale Street when exiting the property. Therefore all exiting vehicles will be
leaving in a forward gear, which is a much safer manoeuvre. This avoids the need for a reversing
vehicle to come to a halt in the middle of the main road.
c) Driveway Grade
Due to the natural topography of the property a vehicle access onto Coral Sea Court would be much
steeper than the proposed access onto Whale Drive. The proposed driveway should therefore be
easier and safer to negotiate without the need for steep approached to the main road.
4. Existing In-Ground Services
It should be noted there is an existing fire hydrant and Telstra pit located within the road verge in the
area of the proposed driveway.
If Sunshine Coast Council approve the proposed driveway location a detailed design will be required
to ensure these services are adequately protected or relocated in accordance with the requirements
of the relevant Service Authorities.
5. Conclusion
Whilst the proposed access is not located the desired distance from the intersection, Tod Consulting
believe the adequate sight lines, low speed environment and low volume of traffic would enable safe
operation of this driveway.
We present the above findings for your review and request your further consideration of a proposed
driveway access on Whale Court.
Prepared by
Greg Jackson (RPEQ 12825)
Tod Consulting Pty Ltd
14 November 2014
4
14717_1 Coral Sea Court, Sunshine Beach - Technical Note_DRAFT
Used in these records