Original source · versioned page text
20181085-ASC4 - Kunkel Plans
Attached to the e-mail Operational Works Application OPW20/0114 - Email 2 of 4 - Civil Plans - Community Titles Scheme Statement - BUP - Part 14 Assessment Benchmarks - 4 Portside Crt, Noosaville.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn drawing index
01 SITE PLAN
02 FLOOR PLAN, FLOOR FRAMING PLAN & TYPICAL SECTION
Project: NEW JETTY
Client: KERREE BEZENCON
N o 9 W I L L S A V E N U E . G O L D E N B E A C H . Q L D . 4551
Address: No. 1/4 PORTSIDE COURT, NOOSAVILLE Q 4566 0409 612 231 | [email protected]
WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721
Lot 1 ON BUP103414 DRAWING NAME REV DATE
COVER SHEET C 10/06/20
A3
DESIGNER PROJECT NO
SD KUNKEL 20.046
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 2 pages
Page 2
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
29.85
0"
52' 2. Extent of site earthworks to be confirmed by
74°
9m
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
m
384
4. All services to be located on site by contractor prior
37. to construction.
183°
5. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
36'40
the Designer for confirmation. Contractor shall verify all
"
dimensions on site prior to construction.
6. Pontoons, gangway, connections & walkway footing
11.757m 23°48'20"
to detail by others.
property details
9.408m 196
No. 1/4 Portside Court,
Noosaville QLD 4566
Noosa Shire Council
°52'30"
Parish - Tewantin
ca County - March
na
Lot 1 on BUP103414
9.4
10.0
0
l
8m
Site Area - 81m²
00m
170
Site Coverage - N/A
°37
0°0'0
'35"
Zone - Attached Housing
9.40 Existing jetty New jetty located greater
"
Overlays - Flood Hazard
8m than 20.0m from existing jetty
144
°22
'30"
24.001 6516 3000
m
131°15
'0
proposed
"
jetty
6000
11.016m
125°52'30
"
11.016m 115°07'30"
po
rt s
id
211°20'50"
67.
728
e
m
existing
units
344
°52
'0"
30.797m
co
emt a
ur
t
285°43'55" signatures
48.291m
road owner/s
gi b s o n 1
site plan builder
1 : 400
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
N o 9 W I L L S A V E N U E . G O L D E N B E A C H . Q L D . 4551 SDK SDK N3 KERREE BEZENCON NEW JETTY SITE PLAN 01 C 20.046 A3
NOR
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
No. 1/4 PORTSIDE COURT, NOOSAVILLE Q 4566
TH
SHEETS IN SET SCALE
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
C 10/06/20 SDK CONSTRUCTION ISSUE Lot 1 ON BUP103414 2 1 : 400
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
Page 3
notes
aluminium framing sizes & connections 1. Contractor to confirm exact siting and orientation
Boundary line
prior to construction setout.
to engineers design & detail
2. All building setout & confirmation of setbacks &
height to be carried out by a Licensed Surveyor.
Floor joists to headstocks 3. Do not scale off drawings, use figured dimensions
to engineers detail only. Any dimensions not nominated must be referred to
the Designer for confirmation. Contractor shall verify all
200x50x3mm aluminium dimensions on site prior to construction.
Aluminium plate fixed
floor joists @ 375 crs to end of jetty 4. Levels & services locations to be confirmed prior to
- 115x38 H4 hwd decking over construction.
Do not fix jetty to
5. Termite protection to be provided in accordance with
2/100x50x6mm rhs revetment wall clause 3.1.4 of the BCA (QLD variation) & AS3660.1.
headstocks per pile Contractor to provide protection information for building
development application.
250x50 H4 hwd fascia to perimeter legend
Headstocks to piles to Denotes dimension to centre line
engineers detail Existing revetment wall
Denotes dimension to outside face
315 dia. pvc insitu piles
to engineers details
section
3 1 : 50
1500
1500 3000 750 750
315 dia. pvc insitu piles
to engineers detail
600
200x50x3mm aluminium
floor joists @ 375mm crs
2400
jetty 250x50 H4 hwd fascia
6000
6000
2/100x50x6mm rhs
headstocks per pile
2400
115x38 H4 hwd
decking over
600
215
215
Boundary Boundary
Existing revetment wall Aluminium plate fixed Existing revetment wall
Do not fix jetty
to end of jetty
to revetment wall
Do not fix jetty
to revetment wall
Boundary
Boundary
signatures
owner/s
floor plan floor framing & footing plan
1 1 : 100
2 1 : 100
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
N o 9 W I L L S A V E N U E . G O L D E N B E A C H . Q L D . 4551 SDK SDK N3 KERREE BEZENCON NEW JETTY FLOOR PLAN, FLOOR FRAMING PLAN & 02 C 20.046 A3
NOR
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
No. 1/4 PORTSIDE COURT, NOOSAVILLE Q 4566
TH
SHEETS IN SET SCALE
QBCC Lic No 1136721 REV DATE DRAWN ISSUE TYPICAL SECTION
C 10/06/20 SDK CONSTRUCTION ISSUE Lot 1 ON BUP103414 2 As indicated
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies