Council archive · source document
DA Form 1, Plans, Form 15, Council Breach Letter · OPW22/0076
Attached to the e-mail Operational Works Application OPW22-00XX 3_5 Sunseeker Close Noosaville Boat lift application.msg.
Plans and drawings: the text below has words only, no drawings.
Version 3— March 2013 Form 15—Compliance Certificate for building Design or Specification NOTE This is to be used for the purposes of section 10 of the Building Act 1975 andlor section 46 of the Building Regulation 2006. RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work complies with the BCA or a provision of the QDC. A building certifier (Class B) can not give a certificate regarding QDC boundary clearance and site cover provisions. 1, Property description Street address include no., street, suburb / locality & postcode) This section need only be completed if ‘generic’ details of street address and property description are applicable. Postcode on case of (standarigenen) | Lot 8 plan details (attach ist if necessary) patio and carport systems this section may tbe eppieae: in which local government area is the land situated? The description must identify all land the ‘generic’ subject of the application. The lot & plan details (eg. SP / RP) are shown on title documents or a rates notice. If the plan is not registered by title, provide previous lot and plan details, 2. Description of component!s certified Clearly describe the extent of work covered by this certificate, e.g. all structural aspects of the steel roof beams. ‘FLOATBRICKS’ POLYETHYLENE (basic) FLOAT MODULE (500mm x 500mm x 400mm) and ANCILLARY CONNECTIONS when used in specific configurations as determined by the Designer: - minimum 5 modules wide (2500mm o’all) per length / run when unpiered - minimum 4 modules wide (2000mm o’all) per length / run when suitably (mooring) piered 3. Basis of certification Detail the basis for giving the certificate and the extent to which tests, specifications, rules, Standards, codes of practice and other publications, were relied upon. AS1170.1, AS1170.2, AS3962 (part), AS4997 BUILDING CODE OF AUSTRALIA (part) Max loading: 1.8Kn point [email protected] wall thickness / 2.7 kPa @ freeboard ~ 100mm in salt water 4, Reference documentation Ciearly identify any relevant documentation, @.9. numbered structural engineering plans. - DOCKPRO (Australia) design specifications - SRB Consulting Engineers performance testing calculations = a a7 = LOCAL GOVERNMENT USE ONLY The Building Act 1975 is administered by the Department of Housing and Public Works Queensland Government
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
DA Form 1, Plans, Form 15, Council Breach Letter.pdfRelated documentApplication case desk ↗
BRW30C9ABB037AA_000332.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.