February, 2008

>

DTS Group Qld - Assessment Report

 

Specific Outcomes

O05 Community Uses and
Infrastructure

Uses , including that identified below,
are able to function effectively during
and immediately after bushfire
events—

a} Emergency service facilities;

b) Hospitals;

c) Education Type 4 uses, including
stores for valuable records or items of
historic or cultural significance; and

d) Service and utility Uses, including
electricity substations, major electrical
depots and water treatment plants.

ldkol eis le aU laes

-| located in a High or

Medium Bushfire Hazard
Area identified on Overidy ©
Maps OM1.4 to OM9.4;

OR

$5.2 Building work will not
involve more than an
additional 20m2 of gGross
fFloor aArea to an existing
building;

OR

$5.3 Where located ina
High or Medium Bushfire
Hazard Area identified on
Overlay Maps OM1.4 to
OM9.4, uses are designed to
function effectively during
and immediately after
bushfire events37.

Proposal
dwelling.

 

Hazardous materials

O6 Public safety and the environment
are not adversely affected by the
detrimental impacts of bushfire on
hazardous materials manufactured or
stored in bulk.

$6.1 Hazardous materials
are not manufactured and
stored on the site.

Complies

Hazardous materials are not
manufactured and stored on the
site

 

k13.34 Siting” design.and construction

 

 

O7 Uses and works including building:
works are sited, designed and
constructed to—

a) minimise the number of people
and property subject to bushfire risk;
and

b) maximise the protection of people
and property during the passage of a
fire front.

 

$7.1 Uses and-works
including building works are
sited—

Q) on lots greater than
2500m2;

i} in locations of lowest
hazard within the lot (Figure
13.5 provides guidance);
and

il) to achieve setbacks from
hazardous vegetation of 1.5
times the predominant
mature canopy tree height
or 10m whichever is the
greater; and

ili) 10m from any retained
vegetation strips or small
areas of vegetation;

and

iv) so that the elements of
the development least
susceptible to fire are sited
closest to the bushfire
hazard;

b) on lots 2500m2 or greater
- to maximize setbacks from
hazardous vegetation37

| Complies - .
As stated above the site only

 

slightly encumbered by the overlay
in the rear of the allotment. It is
considered that the house is
located outside of the overlay. In
any case, the rear of the house will
be provided with setback from the
canopy line of mature vegetation,

 

 

li13.35 Water supply for fire fighting

 

 

 

 

'AO5255A.doc

J 28

 

reed eee eek

Used in these records

About this file

File size
3.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0255 - MCU - Detached House [As Published].pdf · 3.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.