1227 56 RESERVE ST POMONA WD (B) Build Drawings
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
CTRI
CITY
71200 POLE
279 .45
94
EDGE
OF BIT
UMEN
45618
LOT 18
VACA 7
90° 00' 00"
AS OF NT
08.08.
22
278 .17
94
90°00'00"
T
138.26m
138.260 m
EE
.71
7000
7000
90 .66
90
.57
90
0"
TR
.48
90 101 .50
90
SURV
EY .35
277 MARK 90
'0
m
.25
ES
90
9
.8
93
40
°0
CE
E F ING
3 .8 EN
WIRXIST
.74
29
276
93
PROPOSED DWELLING
RV
AIN E
CH 1.2m
179° 40' 00"
T
.36
EE
90
3
81.960 m
TR
LOT 18
.84 '
LOCATION
9
8
9°0
No 56
m
ES
SE
20
33
RV
.35
90
SE
RE
RE
275
.20 0
EDGE 90 90.2
OF TR
EE S
274 .34
93
273
.2
90
.65 5
65 89 9.7
8
EDGE
OF TR
20103 EES
53.87m
100 .97
272 89
SURV
EY MA
00500 RK
.04
90
271
EDGE
OF TR
EES
179°40'00"
20101
81.98m
270
CHAIN
SITE NOTES STORMWATER DRAINAGE NOTES
40301 WIRE
GENERAL NOTES
91701 FE NC
E
1. ALL WORKMANSHIP SHALL BE CARRIED OUT TO THE BEST TRADE DRAINAGE: 1. DP - 90mm DIA DOWNPIPES TO STORMWATER PIPES 100mm MIN
BCA PART 3.12.1 ENERGY EFFICIENCY
STANDARDS AND MATERIAL FIXED IN ACCORDANCE WITH SPECIFIED ALL HOUSEHOLD SEWERAGE AND WASTE TO BE DISCHARGED TO SEWER COVER. 1 IN 100 MIN FALL. THERMAL INSULATION
DETAIL AND MANUFACTURER'S RECOMMENDATIONS. SYSTEM.
2. ONE DOWNPIPE PER 12m OF GUTTER. REDUCE BY 1m FOR ALL WALLS AND ROOF TO COMPLY WITH THE BCA REQUIREMENTS FOR
2. THE FOLLOWING DOCUMENTS FORM PART OF THE SEWER LINE LOCATION TO BE VERIFIED ON SITE AND NO PART OF THE EACH BEND IN GUTTER. THERMAL EFFICIENCY.
DOCUMENTATION FOR THIS PROJECT: PROPOSED RESIDENCE TO BE WITHIN 1500mm OF EDGE OF SEWER PIPE
A.S. 1684.2 RESIDENTIAL TIMBER FRAMED CONSTRUCTION CODE 3. STORMWATER PIPES SHALL BE CONNECTED TO KERB AND FOR CLIMATE ZONE 2, ALTITUDE LESS THAN 300m:
CHANNEL TO LOCAL AUTHORITY REQUIREMENTS.
3. THE ABOVE DOCUMENTS SHOULD BE KEPT ON SITE DURING SURFACE WATER: ROOF CONSTRUCTION TOTAL R-VALUE: MIN 4.6
CONSTRUCTION ALONG WITH THE COPY OF THE LOCAL APPROVED SURFACE WATER TO BE DISCHARGED BY NATURAL FALL OF THE GROUND BULK INSULATION TO ROOF SPACE MIN R-VALUE 3.0
3 46 °
PLANS AND SPECIFICATIONS. CONSTRUCTION MUST NOT VARY FROM AND CUTOFF DRAINS.
5 3.83
THE ABOVE DOCUMENTATION WITHOUT WRITTEN APPROVAL FROM WALL CONSTRUCTION TOTAL R-VALUE: MIN 2.8
THE OWNER AND THE LOCAL AUTHORITY. ALL RAINWATER FROM ROOF DISCHARGE SHALL BE DRAINED AT LEAST 3.0m a) TIMBER FRAMED CONSTRUCTION: BULK WALL INSULATION MIN R-
47 ' 0 0
FROM THE BUILDING FOUNDATION, OR TO LOCAL AUTHORITY VALUE 2.7
4. FIGURED DIMENSIONS TAKE PRECEDENCE OVER SCALING OFF REQUIREMENTS. b) BLOCKWORK OR BRICK VENEER CONSTRUCTION: BULK WALL
0m
PLAN. DO NOT SCALE. ANY DISCREPANCIES FOUND BUT THE BUILDER INSULATION MIN R-VALUE 2.1
/ OWNER SHOULD BE BROUGHT TO THE ATTENTION OT THE
"
DESIGNER PRIOR TO CONSTRUCTION OR FABRICATION OF ANY ITEM.
NORTH
5. RETAIN ALL EXISTING VEGETATION AND MATURE TREES WHERE
POSSIBLE.
6. STRUCTURE SHALL NOT EXCEED 7.9m ABOVE NATURAL GROUND. 270° 00' 00" 142.93m
90°00'00"
7. CHECK ALL DIMENSIONS OF WORKS ON SITE PRIOR TO 142.913 m
COMMENCEMENT OF CONSTRUCTION OR FABRICATION OF ANY ITEM.
REFER DISCREPANCIES TO DESIGNER BEFORE CONSTRUCTION OR
FABRICATION.
SITE COVER
F:\Dropbox\Dropbox Projects\1227 56 Reserve St Pomona\1227 56 RESERVE ST POMONA WD.rvt
8. COMPLY WITH THE BUILDING CODE OF AUSTRALIA (BCA),
RELEVANT AUSTRALIAN STANDARDS AND LOCAL COUNCIL BUILDING SITE PLAN
CODES. 1 1 : 500 Name Area
% SITE
COVER
9. REINF. CONCRETE CROSSOVER TO STREET TO BE IN ACCORDANCE Site Area 12135.98 0.00%
WITH THE LOCAL AUTHORITIES DETAILS AND SPECIFICATION. Site Cover 118.25 0.97%
10. TV ANTENNAE LOCATION TO BE VERIFIED ON SITE BY INSTALLER
DRAWING TITLE SHEET SIZE
REV DATE DESCRIPTION SPECIFICATION NOTES
1 11-8-22 ISSUED FOR REVIEW 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
PROPOSED NEW DWELLING TEL: 0414410463 SITE PLAN
2
A
15-8-22
27-8-22
ISSUED FOR APPROVALS
ISSUED FOR CERTIFICATION
READINGS
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION
3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF [email protected]
A3
AUSTRALIA, RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY
DRAWN PROJECT No PLOT DATE SCALE
B 29-8-22 WINDOWS ADJUSTED FOR STRUCTURAL WALL WWW.SOULSPACE.COM.AU As
BRACING
REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF AT 56 RESERVE ST POMONA Paul Hindes
1227
8/29/2022
indicated
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED. QBSA Lic 1160074 ‐ ABN 81600841459 7:40:20 PM
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF
CONSTRUCTION RPD: L188 MCH1261 23 PALUMA ST SUNRISE BEACH QLD 4567
DRAWING No REVISION
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR. FOR LISA MICOLICH Resort Style Residential and Commercial Designs by Paul Hindes WD 101 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.