Original source · versioned page text
2401 DA02 05032024
Very large file (12.6 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 3, section 1. The text section number identifies this passage in the reader.
¿ play your part - print on recycled paper 5m 4 3 2 1
Swimming pool and spa to be in accordance with engineers design and detail. All
pool construction to be in accordance with manufacturers/installers specifications.
Pool to have suitable pumps located in pool plant store in accordance with K
manufacturers/installers specifications. Provide pool fence to be in accordance with
I 6
ABCB Housing 3 4 5 7
Provisions Standard 2022, the Building Act 1993, Building Regulation 2006, AS 1 2
1926. Pool fence to be min. 1200mm high above adjoining finished surface level and 800 4,400 2,030
have 900mm non climbing zone as specified in pool legislation. Pool to have
structural acrylic wall to be in accordance with structural engineers and specialist
manufacturers design and detail. Pool to be finished with Cemher Provide Cemher
Microdur® (Micro Cement render) system : Colour : Organic. 4, Concrete reventment wall to be in accordance with
59 structural engineers design and detail. Provide
0
EmerProof water proofing barrier to wall with root
barrier guard and 100mm sleeved ag. drain, free
draining back fill. Wall to be in accordance with the
Building Act 1993, Building Regulation 2006, AS 1926 .
Balcony setback
80 Wall to provide pool fence barrier min. 1200mm high
0
column setback
Concrete block retaining wall to be in accordance with structural engineers design J above adjoining finished surface level and have non
2,336
and detail. Provide Soprema Colphene BWS water proofing system to entire climbing zone as specified in pool legislation.
2,905
basement installed in accordance with manufacturers specifications.
600
Balcony setback
top 2,6
E E
2,725
of 70 top 2,6
Balcony setback
co of 70
pin co
g Pool pin Pool to have structural acrylic wall to be in accordance
top 2,6 g
2,021
Tile of 70 with structural engineers and specialist manufacturers
co
pin design and detail. Pool to be finished with Cemher
g
setback
3,600
3,600
Outdoor Living Provide Cemher Microdur® (Micro Cement render)
Tile system : Colour : Organic.
column 40
5,979
Timber framed wall with plasterboard sheeting. Wall to be top 2,6 Spa
6,2
finished with Cemher Microdur® (Micro Cement render) of 70 Tile
co
system : Colour : Truffle. pin
D05 D04 g
W03
D D
W04
Line of bulkhead over shown dashed.
2
FF ,00 316 s/s framed floor access hatch with gas struts to
2,300 Lanai wa 7
2,7 Tile ll access pool plant under.
20
dw
2,7 ffl Formed concrete columns to be in accordance with
Existing concrete block wall to have additional height added to 00 W0
wall in accordance with structural engineers design and detail. sfl 2 structural engineers design and detail. Provide acrylic
dw
Wall to be finished with acrylic render system with sponge render system in accordance with manufacturers
s specifications.
W05
finish and painted. s Dining
H Tile wa 2, H
ll s 307
et
Kitchen Living ba
300 2,000 Tile Tile
ck
Suspended concrete terrace to be in accordance with structural engineers design
Concrete block wall to be in accordance with structural
and detail. Provide fall to outside line of building. Provide EmerProof waterproofing
engineers design and detail. Provide Crackenback
system. Provide selected slip resistance tiles to be installed in accordance with final
stone facing by Eco outdoor.
11,190
11,190
colour selections. be
D06 nc
h 2m Kemlan Horizon Cantilever gas fireplace to be
installed in accordance with manufacturers
Concrete block wall to be in accordance with structural engineers design and detail. co dwn specifications. Provide selected stone faced plinth and
Wall to be finished with acrylic render system with sponge finish and painted. Wall wo wo ref frz
pw shr cantilevered bench to detail.
broom
3
at
on boundary to achieve min. 60/60/60 FRL. K
D0
Fir
se
wc e pl a
G ce G
b
Scullery up
Tile
up
Concrete block wall to be in accordance with structural engineers design and detail. Powder room 17R(169 mm)
18R(196
16G(275mm) b
dw
Tile wc mm)
17G(275 mm) Formed concrete spiral stairs to be in accordance with
Provide Crackenback stone facing by Eco outdoor. Ensuite 4
bench
ice D11 Tile
structural engineers design and detail. Stairs to be in
maker accordance with ABCB Housing Provisions Standard 2022 :
Foyer 11.2 Provide timber framed wall/plasterboard sheeting to form
Knotwood (Light Oak) battens to form batten screen. Battens to be 150 x 25mm D09
e
Tile
rob
sections (120mm cts spacing typical) to have concealed fixings in accordance with Laundry D10 2,7
D0
balustrade. Rebated handrail to comply with ABCB Housing
Tile 20 8 Provisions Standard 2022 : 11.3. Balustrade and exposed
manufacturers specifications. ffl
1
2,7
W0
stairs surface to be finished with Cemher Microdur® (Micro
he
00
ni c
t wm dry sfl Cement render) system : Colour : Truffle. Stair tread and
risers to have selected slip resistant tiles to match floor.
F F
7
C Bedroom 4 C
D0
Tile
W06 W07
2,000
2,000
Lift 2,7 Line of floor over shown dashed.
ECOTRAK 20
Concrete block wall with green roof to be in accordance with structural engineers 2,7 ffl
Series 3
(1C8) 2,
design and detail. Roof to have upvc drainage outlets and EmerProof Landscape 00 30
sfl 7
waterproofing system with premium soil fill and plants to landscapers specifications. B Existing concrete block wall to have additional height
B
Concrete driveway to be in accordance structural engineers design and detail. D0 added to wall in accordance with structural engineers
Provide selected exposed aggregate blend to manufacturers specifications.
2 J design and detail. Wall to be finished with acrylic render
Driveway to comply with AS2890.1. Driveway to connect to existing crossover in system with sponge finish and painted.
accordance with local authority regulations. Driveway grades to be in accordance Reflection pond
with AS2890.1. Driveway to be have clear slip resistant clear penetrating sealer to Tile Concrete block walls to form lift shaft to be in accordance
entire driveway, applied in accordance with manufacturers specifications. with structural engineers design and detail. Lift shaft to suit
wall
ne 6m
ack li s et
E etb Lift ECOTRAK Series 3 by Easy Living Elevators (1C8) E
6,39tback
6m s bac
6,000
6,000
k lin
se
Flow Defence Passive flood barrier to be installed in accordance with manufacturers
Garden
e
8
specifications.
ck
a
etb
wa 021
Flood gate
Planter wall Concrete block walls to form lift shaft to be in accordance
ll s
FF 6,
750 with structural engineers design and detail. Lift shaft to suit
62
Lift ECOTRAK Series 3 by Easy Living Elevators (1C8)
6,1
D D
Garden
Garden
A A
wall
3,65tback
Planter wall
se
4,
Knotwood (Light Oak) battens to form sliding gate panels. Battens to be 25 x 25mm 59
3
0
sections (15mm gap) to be fixed in accordance with manufacturers specifications.
Exposed Agg.
Bin store
Driveway
Exposed Agg. New 2.0m high concrete block wall to be in accordance with
Concrete driveway to be in accordance structural engineers design and detail. Provide selected
structural engineers design and detail. Wall to be finished
exposed aggregate blend to manufacturers specifications. Driveway to comply with AS2890.1. Driveway 80
wall
0 with acrylic render system with sponge finish and painted.
to connect to existing crossover in accordance with local authority regulations. Driveway grades to be in
200 back
set
accordance with AS2890.1. Driveway to be have clear slip resistant clear penetrating sealer to entire
driveway, applied in accordance with manufacturers specifications.
6
5 7
Formed concrete stairs to be in accordance with structural
800 4,400 2,030 engineers design and detail. Stairs to be in accordance with
ABCB Housing Provisions Standard 2022 : 11.2 Stairs to
I have cantilevered treads with selected tile facings.
3 4
1 2 600 & 450mm dia. Concrete pavers in exposed aggregate
blend to manufacturers specifications to match driveway.
A B C Pavers to be have clear slip resistant clear penetrating sealer,
applied in accordance with manufacturers specifications.
Floor plan - Ground floor
1:100
/Users/benthornton/Documents/Cadfiles/2401 - Palazzesi/Archicad/
05032024/2401.pln
sbt designs pty ltd t/a
Skale Building Design project Residence lot no. 145 DA02 Develoment application issue 5/3/2024
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. N21859 DA01 Development applicaiton issue 13/2/2024
2401
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.