Original source · versioned page text
2401 DA02 05032024
Very large file (12.6 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
¿ play your part - print on recycled paper 5m 4 3 2 1
Knotwood (Light Oak) battens to form fence. Battens to be 150 x 25mm
1 2 3 4 sections (300mm spacing typical) to have concealed fixings in accordance
with manufacturers specifications.
800 4,400 2,030
Formed concrete roof beams to be in accordance with structural
Concrete block wall to be in accordance with structural engineers design engineers design and detail. Provide. Exposed surfaces to have acrylic
and detail. Wall to be finished with acrylic render system with sponge render system in accordance with manufacturers specifications.
finish and painted.
Concrete block wall to be in accordance with structural engineers design
and detail. Wall to be finished with acrylic render system with sponge
finish and painted.
9,200
Ceiling
Formed concrete roof (green roof) to be in accordance with structural
engineers design and detail. Roof to have upvc drainage outlets and
3,000
EmerProof Landscape waterproofing system with premium soil fill and
plants to landscapers specifications.
Formed concrete columns to be in accordance with structural engineers
design and detail. Provide acrylic render system in accordance with
manufacturers specifications.
6,200
7,395
First floor
5,600
Existing concrete block wall to have additional height added to wall in
4,950 accordance with structural engineers design and detail. Wall to be finished
with acrylic render system with sponge finish and painted.
3,500
4,200 4,150
3,445
2,700
Ground floor
Concrete driveway to be in accordance structural engineers design and
detail. Provide selected exposed aggregate blend to manufacturers New 2.0m high concrete block wall to be in accordance with structural
specifications. Driveway to comply with AS2890.1. Driveway to connect
3,200
engineers design and detail. Wall to be finished with acrylic render system
to existing crossover in accordance with local authority regulations. with sponge finish and painted.
Driveway grades to be in accordance with AS2890.1. Driveway to be
have clear slip resistant clear penetrating sealer to entire driveway,
applied in accordance with manufacturers specifications.
-500
Basement
Concrete block wall with green roof to be in accordance with structural
Formed concrete stairs to be in accordance with structural engineers engineers design and detail. Roof to have upvc drainage outlets and
design and detail. Stairs to be in accordance with ABCB Housing EmerProof Landscape waterproofing system with premium soil fill and
Provisions Standard 2022 : 11.2 Stairs to have cantilevered treads with plants to landscapers specifications.
selected tile facings. 1 2 3 4
North Western Elevation
NW 1:100
Suspended concrete roof to be in accordance with structural engineers 1 2 3 4 Knotwood (Light Oak) battens to form fence. Battens to be 150 x 25mm
sections (300mm spacing typical) to have concealed fixings in accordance
design and detail. Provide fall to rwo's. Roof to have upvc drainage
outlets and EmerProof waterproofing system. Exposed surfaces fascia & with manufacturers specifications.
soffit to have acrylic render system in accordance with manufacturers 800 4,400 2,030
specifications. Formed concrete roof beams to be in accordance with structural
engineers design and detail. Provide. Exposed surfaces to have acrylic
render system in accordance with manufacturers specifications.
Concrete block wall to be in accordance with structural engineers design
and detail. Wall to be finished with acrylic render system with sponge Concrete block wall to be in accordance with structural engineers design
finish and painted. and detail. Wall to be finished with acrylic render system with sponge
finish and painted.
9,200
Ceiling
Formed concrete roof (green roof) to be in accordance with structural
engineers design and detail. Roof to have upvc drainage outlets and
3,000
EmerProof Landscape waterproofing system with premium soil fill and
plants to landscapers specifications.
Formed concrete columns to be in accordance with structural engineers
design and detail. Provide acrylic render system in accordance with
manufacturers specifications.
6,200
First floor
5,600 Cantilevered glass pool fence to be in accordance with the Building Act
5,800 5,800 1993, Building Regulation 2006, AS 1926 . Pool fence min. 1200mm high
above adjoining finished surface level and have non climbing zone as
Concrete driveway to be in accordance structural engineers design and
specified in pool legislation. Glass panels with rebated channel with non-
detail. Provide selected exposed aggregate blend to manufacturers
3,500
shrink structural grout.
specifications. Driveway to comply with AS2890.1. Driveway to connect
to existing crossover in accordance with local authority regulations.
Driveway grades to be in accordance with AS2890.1. Driveway to be
have clear slip resistant clear penetrating sealer to entire driveway,
3,000
applied in accordance with manufacturers specifications.
2,700
Ground floor
Suspended concrete terrace to be in accordance with structural engineers
Suspended concrete pond to be in accordance with engineers design design and detail. Provide fall to outside line of building. Provide
and detail. Pond to have suitable pumps located in basement service EmerProof waterproofing system. Exposed surfaces fascia & soffit to have
3,200
store in accordance with manufacturers/installers specifications. Pond to acrylic render system in accordance with manufacturers specifications.
have max. 300mm standing water depth with no pool fence to be in Provide selected slip resistance tiles to be installed in accordance with
accordance with NCC 3.9.3, the Building Act 1993, Building Regulation final colour selections.
2006, AS 1926. -150
-500
Basement
Concrete block retaining wall to be in accordance with structural
engineers design and detail. Provide EmerProof water proofing barrier to
wall with root barrier guard and 100mm sleeved ag. drain, free draining
back fill.
1 2 3 4
North Western Elevation
NW1 1:100
/Users/benthornton/Documents/Cadfiles/2401 - Palazzesi/Archicad/
05032024/2401.pln
sbt designs pty ltd t/a
Skale Building Design project Residence lot no. 145 DA02 Develoment application issue 5/3/2024
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. N21859 DA01 Development applicaiton issue 13/2/2024
2401
skale
CD04 Conceptual design issue 9/2/2024
skale.com.au 38 Mossman Court drawn BT
CD02 Conceptual design issue 7/2/2024
drawing number
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at Noosa Sound scale (A2) 1:100 Rev Details Date 06 DA02 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.