Original source · versioned page text
Approved Plans MCU16-0117.01.pdf
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
AREA LEGEND
EXISTING RESIDENCE
TOTAL AREA 105m2
6630 5652 6000
SETBACK SETBACK SETBACK
50.29 PROPOSED AREA
SETBACK
2400
GROUND FLOOR 105m2
FRONT DECK 10m2
3710 FRONT DECK 17m2
SETBACK 4900
SETBACK
TOTAL 137m2
TYPE B TYPE A
30.40
30.69
DESIGNED IN
DIAMOND LANE
ACCORDANCE WITH BCA
- STAIRS TO COMPLY WITH PART 3.9.1 & 3.9.2
- STAIRS TO HAVE A NON-SLIP RESISTANCE & COMPLY
OPAL ST
WITH PART 3.9.1.3
- STAIR HANDRAILS REQUIRED AS PER PART 3.9.2.4
- BALUSTRADES TO COMPLY WITH PART 3.9.2
- GLASS BALUSTRADES TO COMPLY WITH AS1288:2006. TO
HAVE INTERLINKING HANDRAIL
- TERMITE PROTECTION TO COMPLY WITH AS3660.1
- WC DOORS TO COMPLY WITH PART 3.8.3.3
4900
4860 SETBACK
- ALL WET AREAS TO COMPLY WITH 3.8.1
SETBACK - LIGHTING TO COMPLY WITH 3.8.4
- VENTILATION TO COMPLY WITH 3.8.5
- FLASHING TO WALL OPENINGS 3.5.3.6
3780
SETBACK
- GLAZING & WINDOW ASSEMBLIES - 3.6.0
- AUTO SMOKE DETECTION & ALARM SYSTEM - 3.7.2.2
TYPE B TYPE A
- ENERGY EFFICIENCY - 3.12, 2011
- WINDOW PROTECTION TO COMPLY WITH 3.9.2.5.
PROPOSED NOTES
RESIDENCE
- ALL DIMENSIONS TO BE CONFIRMED ON SITE PRIOR TO
COMMENCEMENT OF FABRICATION
- BUILDER TO MAINTAIN STRUCTURAL INTEGRITY AT ALL
TIMES.
- REFER STRUCTURAL ENGINEER'S DRAWINGS FOR DETAILS OF
ALL REINFORCED CONC. SLABS, FOOTINGS, RETAINING WALLS,
TIMBER FRAMING, TIE-DOWN & BRACING.
- DOWNPIPES TO CONNECT TO EXISTING STORMWATER LINE OR
SETBACK
3000
RAINWATER TANKS
- ALL WORK TO MATCH EXISTING
50.29 - ALL EXTERNAL STEEL WORK INCLUDING FIXINGS TO BE HOT
DIPPED GALVANISED
- ANY DAMAGE CAUSED BY DEMOLITION TO BE MADE GOOD
5800 6000 - OWNERS TO SELECT FINISHES, FIXTURES & LIGHTING
LINE OF NEW LINE OF BUILDING SETBACK SETBACK
- WHILE GREAT CARE HAS BEEN TAKEN TO BE AS ACCURATE
DECK BELOW BELOW LINE OF NEW AS POSSIBLE, BUILDER IS TO CONFIRM DIMENSIONS ON SITE
DECK BELOW BEFORE CONSTRUCTION
- BUILDER TO CONFIRM SIZES ON SITE BEFORE ORDERING
DOORS & WINDOWS
- ALL TIMBER USED IS TO BE FSC APPROVED
SITE PLAN PROPOSED
1
SCALE
SCALE1:200
1:200
@@A3A3
PROPOSED RESIDENCE No1
11 OPAL STREET COOROY SITE PLAN PROPOSED
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Approved Plans MCU16-0117.01.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 30 pages
Page 2
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
12950
2400 3650
DECK DECK
900
2500 2750
ENS ROOF
2360
ENS
ROOF
3650
RB ENS RB
BED 2 DECK
STUDY BED 1
1200
AL FRESCO
DN
LINE OF ROOF OVER
720
ROOF
DECK
7360
8260
7360
DN
DECK
1650
REF
DINING LOUNGE
KITCHEN LIVING
PANTRY
LAUNDRY/
BATHROOM
3350 4100
LAUNDRY/ KITCHEN 900
2250
BATHROOM
ROOF
15700
FIRST FLOOR PLAN - PROPOSED
3
SCALE 1:100 @ A3
PROPOSED RESIDENCE No1
11 OPAL STREET COOROY FIRST FLOOR PLAN PROPOSED
Page 3
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
18997,5
90 90
900 3580 2490
BED 1 STUDY
1212 1212
90
UP
2200
STUDY
BED 1
BED 1 STUDY
3550
3550
AL FRESCO
70
1290
820
RB RB
100
CAR PARKING CAR PARKING
7360
7360
720
900 770
90
1500
PTY
900
2230
BTH
BTH
KITCHEN
LIVING/DINING KITCHEN
3510
720
90
0912
LDY
1200
UP
LDY
720
820
100
0912 0912 0912
1600
PORCH
1800
5900 2910 1883,83 3337 3600
100 90 90 90 100
LDY LIVING/DINING KITCHEN
1883,83
BTH
18100
GROUND FLOOR PLAN - PROPOSED
4 SCALE 1:100 @ A3
PROPOSED RESIDENCE No1
11 OPAL STREET COOROY GROUND FLOOR PLAN PROPOSED
Page 4
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
PROPOSED GABLE ROOF
ROOF BEAM BRACKET AND TIMBER POST TO MATCH EXISTING ROOF
FIX TO EXISTING STRUCTURE
REFER TO ENGINEERS SPECIFICATIONS
STRUCTURAL POST
TO ENGINEERS
SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
22.5 PITCH
FIRST FLOOR CEILING
2800 HEIGHT
CEILING
250
FIRST FLOOR PLAN EXISTING
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
2400
GROUND FLOOR PLAN
FT FT FT FT FT FT
SUPPORTING FLOOR STRUCTURE
TO ENGINEER'S SPECIFICATIONS
CONCRETE FOOTING WITH STEEL POST DESIGN
TO STRUCTURAL ENGINEERS SPECIFICATION'S
TIMBER BALUSTRADE TO CLIENTS TIMBER FLOOR AND SUPPORTING FLOOR
SELECTION 1000mmH MIN STRUCTURE TO ENGINEER'S SPECIFICATIONS
NORTH SECTIONAL ELEVATION
1 SCALE 1:100 @ A3
PROPOSED RESIDENCE No1
11 OPAL STREET COOROY NORTH SECTIONAL ELEVATION
Page 5
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
2800
250
FIRST FLOOR PLAN EXISTING
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
2400
GROUND FLOOR PLAN
FT FT FT FT FT
CONCRETE FOOTING WITH STEEL POST DESIGN
TO STRUCTURAL ENGINEERS SPECIFICATION'S
TIMBER BALUSTRADE TO CLIENTS
SELECTION 1000mmH MIN
SOUTH SECTIONAL ELEVATION
2 SCALE 1:100 @ A3
PROPOSED RESIDENCE No1
11 OPAL STREET COOROY SOUTH SECTIONAL ELEVATION
Page 6
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
COLORBOND INSULATED ROOF SHEETING,
PROFILE AND COLOUR TO CLIENTS
SELECTION. INSTALL AS PER MANUFACTURERS
BOUNDARY LINE
BOUNDARY LINE
STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
FIRST FLOOR CEILING
2800 HEIGHT
CEILING
250
FIRST FLOOR PLAN EXISTING
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
2400
GROUND FLOOR PLAN
FT FT FT FT FT FT FT FT
SUPPORTING FLOOR STRUCTURE
TO ENGINEER'S SPECIFICATIONS
CONCRETE FOOTING WITH STEEL POST DESIGN
TO STRUCTURAL ENGINEERS SPECIFICATION'S
EAST SECTIONAL ELEVATION
3 SCALE 1:100 @ A3
PROPOSED RESIDENCE No1
11 OPAL STREET COOROY EAST SECTIONAL ELEVATION
Page 7
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
STRUCTURAL POST COLORBOND INSULATED ROOF SHEETING,
TO ENGINEERS SPECIFICATIONS PROFILE AND COLOUR TO CLIENTS
SELECTION. INSTALL AS PER MANUFACTURERS
BOUNDARY LINE
BOUNDARY LINE
STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
FIRST FLOOR CEILING
CEILING HEIGHT
2800
250
FIRST FLOOR PLAN EXISTING
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
2400
GROUND FLOOR PLAN
FT FT FT FT FT FT FT FT FT FT FT
SUPPORTING FLOOR STRUCTURE
TO ENGINEER'S SPECIFICATIONS
TIMBER FLOOR AND SUPPORTING FLOOR
STRUCTURE TO ENGINEER'S SPECIFICATIONS
CONCRETE FOOTING WITH STEEL POST DESIGN
TO STRUCTURAL ENGINEERS SPECIFICATION'S
WEST SECTIONAL ELEVATION
4 SCALE 1:100 @ A3
PROPOSED RESIDENCE No1
11 OPAL STREET COOROY WEST SECTIONAL ELEVATION
Page 8
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
6630 5652,1 6000
SETBACK SETBACK SETBACK
AREA LEGEND
50.29
SETBACK
2400
EXISTING RESIDENCE
TOTAL AREA 102m2
3710
SETBACK 4900
SETBACK
TYPE B TYPE A PROPOSED AREA
30.40
30.69
FRONT DECK 13m2
CAR PARKING 40m2
TOTAL 137m2
DESIGNED IN
DIAMOND LANE
ACCORDANCE WITH BCA
- STAIRS TO COMPLY WITH PART 3.9.1 & 3.9.2
- STAIRS TO HAVE A NON-SLIP RESISTANCE & COMPLY
OPAL ST
WITH PART 3.9.1.3
- STAIR HANDRAILS REQUIRED AS PER PART 3.9.2.4
- BALUSTRADES TO COMPLY WITH PART 3.9.2
- GLASS BALUSTRADES TO COMPLY WITH AS1288:2006. TO
HAVE INTERLINKING HANDRAIL
- TERMITE PROTECTION TO COMPLY WITH AS3660.1
- WC DOORS TO COMPLY WITH PART 3.8.3.3
4900 - ALL WET AREAS TO COMPLY WITH 3.8.1
4860 SETBACK
SETBACK - LIGHTING TO COMPLY WITH 3.8.4
- VENTILATION TO COMPLY WITH 3.8.5
- FLASHING TO WALL OPENINGS 3.5.3.6
3780 - GLAZING & WINDOW ASSEMBLIES - 3.6.0
SETBACK
- AUTO SMOKE DETECTION & ALARM SYSTEM - 3.7.2.2
- ENERGY EFFICIENCY - 3.12, 2011
TYPE B TYPE A - WINDOW PROTECTION TO COMPLY WITH 3.9.2.5.
PROPOSED NOTES
RESIDENCE
- ALL DIMENSIONS TO BE CONFIRMED ON SITE PRIOR TO
COMMENCEMENT OF FABRICATION
- BUILDER TO MAINTAIN STRUCTURAL INTEGRITY AT ALL
TIMES.
- REFER STRUCTURAL ENGINEER'S DRAWINGS FOR DETAILS OF
ALL REINFORCED CONC. SLABS, FOOTINGS, RETAINING WALLS,
TIMBER FRAMING, TIE-DOWN & BRACING.
- DOWNPIPES TO CONNECT TO EXISTING STORMWATER LINE OR
SETBACK
3000
RAINWATER TANKS
- ALL WORK TO MATCH EXISTING
50.29 - ALL EXTERNAL STEEL WORK INCLUDING FIXINGS TO BE HOT
DIPPED GALVANISED
- ANY DAMAGE CAUSED BY DEMOLITION TO BE MADE GOOD
5800 6000 - OWNERS TO SELECT FINISHES, FIXTURES & LIGHTING
LINE OF NEW LINE OF BUILDING SETBACK SETBACK
- WHILE GREAT CARE HAS BEEN TAKEN TO BE AS ACCURATE
DECK BELOW BELOW LINE OF NEW AS POSSIBLE, BUILDER IS TO CONFIRM DIMENSIONS ON SITE
DECK BELOW BEFORE CONSTRUCTION
- BUILDER TO CONFIRM SIZES ON SITE BEFORE ORDERING
DOORS & WINDOWS
- ALL TIMBER USED IS TO BE FSC APPROVED
SITE PLAN PROPOSED
1
SCALE
SCALE1:200
1:200
@@A3A3
PROPOSED RESIDENCE No 2
11 OPAL STREET COOROY SITE PLAN PROPOSED
Page 9
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
90 90 90
600 2700 900 2200 6930
BTH
100
PTY
RB
ENS
2490
BTH
ENS
KTICHEN
BED 1
DINING
3480
3480
3480
BED 1 DINING KITCHEN
1000
750
900 1000
RB
REF
90
DECK
7430
7430
7430
DN DECK
90
850
TOILET
90
TOILET
900
LIVING
STUDY
3660
3660
LIVING
BED 2
2720
BED 2
RB RB
UP
100 90
90 90
1800 5500 900 3035 600 3295
DECK LIVING BED 2 STUDY
900
13800
STAIR
FIRST FLOOR PLAN - PROPOSED
1
SCALE 1:100 @ A3
PROPOSED RESIDENCE No 2
11 OPAL STREET COOROY
Page 10
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
2100
2400
BATHROOM
LDY
TIMBER POST
100x100
CAR PARKING
7430
2900
LOUNGE PORCH
1600
UP 5507,5
13800
GROUND FLOOR PLAN - PROPOSED
2 SCALE 1:100 @ A3
PROPOSED RESIDENCE No 2
11 OPAL STREET COOROY
Page 11
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
ROOF BEAM BRACKET AND TIMBER POST
FIX TO EXISTING STRUCTURE
REFER TO ENGINEERS SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
2700
250
FIRST FLOOR PLAN
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
GROUND FLOOR PLAN
FT FT FT FT FT FT FT FT
CONCRETE FOOTING WITH STEEL POST DESIGN
TO STRUCTURAL ENGINEERS SPECIFICATION'S
EAST SECTIONAL ELEVATION
5 SCALE 1:100 @ A3
PROPOSED RESIDENCE No 2
11 OPAL STREET COOROY
Page 12
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
COLORBOND INSULATED SKILLION ROOF,
PROFILE AND COLOUR TO
CLIENTS SELECTION.
INSTALL AS PER MANUFACTURER'S
STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
26.5 PITCH
FIRST FLOOR CEILING
CEILING HEIGHT
2700
250
FIRST FLOOR PLAN
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
GROUND FLOOR PLAN
FT FT FT FT FT FT
SUPPORTING FLOOR STRUCTURE
TO ENGINEER'S SPECIFICATIONS
TIMBER BALUSTRADE TO CLIENTS
CONCRETE FOOTING WITH STEEL POST DESIGN SELECTION 1000mmH MIN
TO STRUCTURAL ENGINEERS SPECIFICATION'S
GALVANIZES STEEL FRAMED
HWD TIMBER STAIR
TIMBER FLOOR FRAMING. REFER TO
FRAMING PLAN AND STRUCTURAL
ENGINEERS SPECIFICATION'S. FOR DETAILS
SOUTH SECTIONAL ELEVATION
3 SCALE 1:100 @ A3
PROPOSED RESIDENCE No 2
11 OPAL STREET COOROY
Page 13
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
ROOF BEAM BRACKET AND TIMBER POST
FIX TO EXISTING STRUCTURE
REFER TO ENGINEERS SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
2700
250
FIRST FLOOR PLAN
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
GROUND FLOOR PLAN
FT FT FT FT FT
CONCRETE FOOTING WITH STEEL POST DESIGN
TO STRUCTURAL ENGINEERS SPECIFICATION'S
NORTH SECTIONAL ELEVATION
4 SCALE 1:100 @ A3
PROPOSED RESIDENCE No 2
11 OPAL STREET COOROY
Page 14
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
COLORBOND INSULATED SKILLION ROOF,
PROFILE AND COLOUR TO
CLIENTS SELECTION.
INSTALL AS PER MANUFACTURER'S
STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
2700
250
FIRST FLOOR PLAN
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
GROUND FLOOR PLAN
FT FT FT FT FT FT FT FT
SUPPORTING FLOOR STRUCTURE
TO ENGINEER'S SPECIFICATIONS
CONCRETE FOOTING WITH STEEL POST DESIGN
TO STRUCTURAL ENGINEERS SPECIFICATION'S
WEST SECTIONAL ELEVATION
6 SCALE 1:100 @ A3
PROPOSED RESIDENCE No 2
11 OPAL STREET COOROY
Page 15
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
AREA LEGEND
EXISTING RESIDENCE
6630 5652 6000
SETBACK SETBACK SETBACK
TOTAL AREA 110m2
50.29
SETBACK
2400
PROPOSED AREA
3710 FRONT DECK 6.5m2
SETBACK 4900
SETBACK
BACK DECK 15m2
TYPE B TYPE A GROUND FLOOR LEVEL 126m2
30.40
30.69
TOTAL 147.5m2
PROPOSED
RESIDENCE
DESIGNED IN
DIAMOND LANE
ACCORDANCE WITH BCA
- STAIRS TO COMPLY WITH PART 3.9.1 & 3.9.2
- STAIRS TO HAVE A NON-SLIP RESISTANCE & COMPLY
OPAL ST
WITH PART 3.9.1.3
- STAIR HANDRAILS REQUIRED AS PER PART 3.9.2.4
- BALUSTRADES TO COMPLY WITH PART 3.9.2
- GLASS BALUSTRADES TO COMPLY WITH AS1288:2006. TO
HAVE INTERLINKING HANDRAIL
- TERMITE PROTECTION TO COMPLY WITH AS3660.1
- WC DOORS TO COMPLY WITH PART 3.8.3.3
4900
4860 SETBACK
- ALL WET AREAS TO COMPLY WITH 3.8.1
SETBACK - LIGHTING TO COMPLY WITH 3.8.4
- VENTILATION TO COMPLY WITH 3.8.5
- FLASHING TO WALL OPENINGS 3.5.3.6
3780
SETBACK
- GLAZING & WINDOW ASSEMBLIES - 3.6.0
- AUTO SMOKE DETECTION & ALARM SYSTEM - 3.7.2.2
- ENERGY EFFICIENCY - 3.12, 2011
TYPE B TYPE A - WINDOW PROTECTION TO COMPLY WITH 3.9.2.5.
NOTES
- ALL DIMENSIONS TO BE CONFIRMED ON SITE PRIOR TO
COMMENCEMENT OF FABRICATION
- BUILDER TO MAINTAIN STRUCTURAL INTEGRITY AT ALL
TIMES.
- REFER STRUCTURAL ENGINEER'S DRAWINGS FOR DETAILS OF
ALL REINFORCED CONC. SLABS, FOOTINGS, RETAINING WALLS,
TIMBER FRAMING, TIE-DOWN & BRACING.
- DOWNPIPES TO CONNECT TO EXISTING STORMWATER LINE OR
SETBACK
3000
RAINWATER TANKS
- ALL WORK TO MATCH EXISTING
50.29 - ALL EXTERNAL STEEL WORK INCLUDING FIXINGS TO BE HOT
DIPPED GALVANISED
- ANY DAMAGE CAUSED BY DEMOLITION TO BE MADE GOOD
5800 6000 - OWNERS TO SELECT FINISHES, FIXTURES & LIGHTING
LINE OF NEW LINE OF BUILDING SETBACK SETBACK
- WHILE GREAT CARE HAS BEEN TAKEN TO BE AS ACCURATE
DECK BELOW BELOW LINE OF NEW AS POSSIBLE, BUILDER IS TO CONFIRM DIMENSIONS ON SITE
DECK BELOW BEFORE CONSTRUCTION
- BUILDER TO CONFIRM SIZES ON SITE BEFORE ORDERING
DOORS & WINDOWS
- ALL TIMBER USED IS TO BE FSC APPROVED
SITE PLAN PROPOSED
1
SCALE
SCALE1:200
1:200
@@A3A3
PROPOSED RESIDENCE No3
11 OPAL STREET COOROY SITE PLAN PROPOSED
Page 16
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
14170
90 90
1840 3050 4000 2600 900 3150 2000
DECK DINING KITCHEN BATH STUDY DECK
RANGEHOOD
STAIR
900
TOILET
BATH
2270
2270
KITCHEN
STUDY
KITCHEN
PTY TOILET
3152
2960
BATH
DINING
DINING
STUDY
4110
90
DN REF
600
LINEN
DECK
1150
1150
7380
7380
DECK
90
DECK
RB
LOUNGE
LVING
2980
2980
BED 1
BED 2
LIVING
3600
3600
LOUNGE BED 1
BED 2
BATHROOM
620
PORCH
1770 2430 1000 4250
90 BED 2 90 90 BED 1
BATHROOM
4250 9920
FIRST FLOOR PLAN - PROPOSED
2
SCALE 1:100 @ A3
PROPOSED RESIDENCE No 3
11 OPAL STREET COOROY
Page 17
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
16070
90 90 90
2709 600 3505 1410 1500 5937
STUDY BED 1 LDY LDY
900
STAIR
LDY
LDY
1500
LDY
RB
BED 1
BED 1
3107
3107
BED 1
STUDY
SHELVE
90
1000
1000
8000
BATH
CAR PARKING CAR PARKING
1800
BTH
LIVING/DINING
90
3982
LIVING/DINING
KITCHEN
2712
KITCHEN
PTY
1600
PORCH
900
STAIR
2190
2655
BATH
4150 2655 2910 5937
LIVING/DINING 100 KITCHEN 90 90
GROUND FLOOR PLAN - PROPOSED
3
SCALE 1:100 @ A3
PROPOSED RESIDENCE No 3
11 OPAL STREET COOROY
Page 18
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
COLORBOND INSULATED SKILLION ROOF,
PROFILE AND COLOUR TO
CLIENTS SELECTION.
INSTALL AS PER MANUFACTURER'S
STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
2700
250
FIRST FLOOR PLAN
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
2400
GROUND FLOOR PLAN
FT FT FT FT FT
SUPPORTING FLOOR STRUCTURE
TO ENGINEER'S SPECIFICATIONS
GALVANIZES STEEL FRAMED
CONCRETE FOOTING WITH STEEL POST DESIGN HWD TIMBER STAIR
TO STRUCTURAL ENGINEERS SPECIFICATION'S
TIMBER FLOOR FRAMING. REFER TO
TIMBER BALUSTRADE TO CLIENTS FRAMING PLAN AND STRUCTURAL
SELECTION 1000mmH MIN ENGINEERS SPECIFICATION'S. FOR DETAILS
NORTH SECTIONAL ELEVATION
4 SCALE 1:100 @ A3
PROPOSED RESIDENCE No 3
11 OPAL STREET COOROY
Page 19
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
COLORBOND INSULATED SKILLION ROOF,
PROFILE AND COLOUR TO
CLIENTS SELECTION.
INSTALL AS PER MANUFACTURER'S
STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
2700
250
FIRST FLOOR PLAN
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
2400
GROUND FLOOR PLAN
FT FT FT FT
SUPPORTING FLOOR STRUCTURE
TO ENGINEER'S SPECIFICATIONS
CONCRETE FOOTING WITH STEEL POST DESIGN
TO STRUCTURAL ENGINEERS SPECIFICATION'S
TIMBER BALUSTRADE TO CLIENTS
SELECTION 1000mmH MIN
SOUTH SECTIONAL ELEVATION
5 SCALE 1:100 @ A3
PROPOSED RESIDENCE No 3
11 OPAL STREET COOROY
Page 20
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
COLORBOND INSULATED SKILLION ROOF,
PROFILE AND COLOUR TO
CLIENTS SELECTION.
INSTALL AS PER MANUFACTURER'S
STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
2700
250
FIRST FLOOR PLAN
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
2400
GROUND FLOOR PLAN
FT FT FT FT FT FT FT FT
SUPPORTING FLOOR STRUCTURE
TO ENGINEER'S SPECIFICATIONS
EAST SECTIONAL ELEVATION
6 SCALE 1:100 @ A3
PROPOSED RESIDENCE No 3
11 OPAL STREET COOROY
Page 21
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
COLORBOND INSULATED SKILLION ROOF,
PROFILE AND COLOUR TO
CLIENTS SELECTION.
ROOF BEAM BRACKET AND TIMBER POST
INSTALL AS PER MANUFACTURER'S
FIX TO EXISTING STRUCTURE
REFER TO ENGINEERS SPECIFICATIONS
STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
2700
250
FIRST FLOOR PLAN
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2700
2400
SP
GROUND FLOOR PLAN
FT FT FT FT FT FT FT
SUPPORTING FLOOR STRUCTURE
TO ENGINEER'S SPECIFICATIONS STRUCTURAL POST
TO ENGINEERS SPECIFICATIONS
WEST SECTIONAL ELEVATION
7 SCALE 1:100 @ A3
PROPOSED RESIDENCE No 3
11 OPAL STREET COOROY
Page 22
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
6630 5652 6000
SETBACK SETBACK SETBACK
AREA LEGEND
50.29
SETBACK
2400
EXISTING RESIDENCE
3710
SETBACK 4900 TOTAL AREA 90m2
SETBACK
TYPE B TYPE A
PROPOSED AREA
30.40
30.69
PROPOSED
RESIDENCE FRONT DECK 14.5m2
PATIO 14m2
GROUND FLOOR LEVEL 90m2
TOTAL 111.5m2
DIAMOND LANE
OPAL ST
4900
4860 SETBACK
SETBACK
3780
SETBACK
TYPE B TYPE A
SETBACK
3000
50.29
5800 6000
LINE OF NEW LINE OF BUILDING SETBACK SETBACK
DECK BELOW BELOW LINE OF NEW
DECK BELOW
SITE PLAN PROPOSED
1
SCALE
SCALE1:200
1:200
@@A3A3
PROPOSED RESIDENCE No4
11 OPAL STREET COOROY SITE PLAN PROPOSED
Page 23
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
3000
250
FIRST FLOOR PLAN EXISTING
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2400
GROUND FLOOR PLAN
FT FT FT FT FT FT FT FT FT
EAST SECTIONAL ELEVATION
8
SCALE 1:100 @ A3
PROPOSED SITE PLAN FOR RESIDENCES ON
11 OPAL STREET COOROY EAST SECTIONAL ELEVATION
Page 24
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
8585
4521,88 8395 1610
DECK
4230 4045 4400
KITCHEN LIVING DECK
KITCHEN
LIVING
DECK
DECK
3860
3760
3770
KITCHEN FRONT DECK
LIVING
DN
ENTRY
DECK
7797,42
7795
DN
ENSUITE
BATHROOM/
ENSUITE
MASTER
BED 3
BED2
BED 3
3735
3735
3735
3735
MASTER
BED 2
BATHROOM
2250
1500 1563,78
ENSUITE
3000 3000 2168,88 900 600 2999,99
BED 3 BED 2 BATHROOM MASTER
13230
FIRST FLOOR PLAN - PROPOSED
4 SCALE 1:100 @ A3
PROPOSED RESIDENCE No4
FIRST FLOOR PLAN PROPOSED
11 OPAL STREET COOROY
Page 25
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
2304,62
LOUNGE
LOUNGE
3844,74
LOUNGE
7795
LAUNDRY
LAUNDRY
3234,5
CAR PARKING
UP
UP
1354,98 6000
LAUNDRY
13230
GROUND FLOOR PLAN - PROPOSED
3
SCALE 1:100 @ A3
PROPOSED RESIDENCE No4
GROUND FLOOR PROPOSED
11 OPAL STREET COOROY
Page 26
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
3000
250
FIRST FLOOR PLAN EXISTING
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2400
GROUND FLOOR PLAN
FT FT FT FT FT FT FT
NORTH SECTIONAL ELEVATION
5
SCALE 1:100 @ A3
PROPOSED RESIDENCE No4
11 OPAL STREET COOROY NORTH SECTIONAL ELEVATION
Page 27
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
3000
250
FIRST FLOOR PLAN EXISTING
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2400
GROUND FLOOR PLAN
FT FT FT FT FT FT FT FT
WEST SECTIONAL ELEVATION
7
SCALE 1:100 @ A3
PROPOSED RESIDENCE No4
11 OPAL STREET COOROY
Page 28
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0117.01 10 DEC 2018
BOUNDARY LINE
BOUNDARY LINE
FIRST FLOOR CEILING
CEILING HEIGHT
3000
250
FIRST FLOOR PLAN EXISTING
GROUND FLOOR CEILING
PROPOSED CEILING HEIGHT
2400
GROUND FLOOR PLAN
FT FT FT FT
STEEL POST. REFER TO ENGINEER
SPECIFICATIONS
CONCRETE FOOTING WITH STEEL POST
DESIGN TO STRUCTURAL ENGINEERS SPECIFICATIONS
SOUTH SECTIONAL ELEVATION
6 TIMBER FLOOR FRAMING. REFER TO
SCALE 1:100 @ A3 FRAMING PLAN AND STRUCTURAL
ENGINEERS SPECIFICATIONS
GALVANIZES STEEL FRAMED HWD
TIMBER STAIR WITH BALUSTRADE.
PROPOSED RESIDENCE No4
11 OPAL STREET COOROY SOUTH SECTIONAL ELEVATION
Page 29
LINDSAY CONSULTING PTY
LTD
GARAGE 1000lt Slimline water tanks.
Outlet to drain to centre 300 GARAGE
FSL 109.10 pipe
FSL 109.10
8000 Min Passing length
1000lt Slimline water tanks.
Outlet to drain to centre 300
RS-051
00
pipe
9.
10
.40
PL
PL 8
1 0 10
0 9.
10 0 8.7 PL
8.70 L1 8.60PL
PL PL 10 P P L 1 0
108
10 PL PL .4
09. 10 1 08. 108. 0
P L1 8 .9 80 70
0
00
PL
9.
10
10
9.
PL
00
GARAGE GARAGE
FSL 109.10 FSL 109.10
1000lt Slimline water tanks.
Outlet to drain to centre 300
pipe
APPROVED PLANS
MCU16/0117 & OPW16/0212
NOOSA COUNCIL PL 9.50
16 MARCH 2017
Page 30
LINDSAY CONSULTING PTY
LTD
APPROVED PLANS
MCU16/0117 & OPW16/0212
NOOSA COUNCIL
16 MARCH 2017
As Amended by Conditions
Page 31
LINDSAY CONSULTING PTY
LTD
APPROVED PLANS
MCU16/0117 & OPW16/0212
NOOSA COUNCIL