Approved Plans MCU16-0117.01.pdf

of 31
                                                                                                                                                                                                                                     -

                                                                                                                                                                                                                          NOOSA COUNCIL
                                                                                                                                                                                                                          APPROVED PLAN
                                                                                                                                                                                                                      MCU16/0117.01 10 DEC 2018




                                                                                                           PROPOSED GABLE ROOF
ROOF BEAM BRACKET AND TIMBER POST                                                                          TO MATCH EXISTING ROOF
FIX TO EXISTING STRUCTURE
REFER TO ENGINEERS SPECIFICATIONS

                                                                                             STRUCTURAL POST
                                                                                             TO ENGINEERS
                                                                                             SPECIFICATIONS




                                                BOUNDARY LINE




                                                                                                                  BOUNDARY LINE
                                                                                         22.5 PITCH


                                                                                                                                        FIRST FLOOR CEILING




                                                                                                                                                                                                  2800 HEIGHT
                                                                                                                                                                                               CEILING


                                                                                                                                                                                                                250
                                                                                                                                  FIRST FLOOR PLAN EXISTING


                                                                                                                                    GROUND FLOOR CEILING




                                                                                                                                                              PROPOSED CEILING HEIGHT



                                                                                                                                                                                                    2700
                                                                                                                                                                                        2400
                                                                                                                                       GROUND FLOOR PLAN


                                                                FT   FT   FT   FT   FT                FT


                                                                                                                                                                SUPPORTING FLOOR STRUCTURE
                                                                                                                                                                TO ENGINEER'S SPECIFICATIONS




        CONCRETE FOOTING WITH STEEL POST DESIGN
        TO STRUCTURAL ENGINEERS SPECIFICATION'S


                   TIMBER BALUSTRADE TO CLIENTS                                                                                                        TIMBER FLOOR AND SUPPORTING FLOOR
                   SELECTION 1000mmH MIN                                                                                                               STRUCTURE TO ENGINEER'S SPECIFICATIONS




                              NORTH SECTIONAL ELEVATION
                      1      SCALE 1:100 @ A3




                                                                                                                                     PROPOSED RESIDENCE No1
                                                                                                                                     11 OPAL STREET COOROY                                                                NORTH SECTIONAL ELEVATION

Log in to download the original (Approved Plans MCU16-0117.01.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.