Approved Plans MCU16-0117.01.pdf

of 31
                                                                                                                                                                                                                                                                -

                                                                                                                                                                                                                                        NOOSA COUNCIL
                                                                                                                                                                                                                                        APPROVED PLAN
                                                                                                                                                                                                                                    MCU16/0117.01 10 DEC 2018




                                                                                                                                 STRUCTURAL POST                                                                      COLORBOND INSULATED ROOF SHEETING,
                                                                                                                                 TO ENGINEERS SPECIFICATIONS                                                          PROFILE AND COLOUR TO CLIENTS
                                                                                                                                                                                                                      SELECTION. INSTALL AS PER MANUFACTURERS
                            BOUNDARY LINE




                                                                                                                                                                                                                                                                    BOUNDARY LINE
                                                                                                                                                                                                                            STRUCTURAL POST
                                                                                                                                                                                                                            TO ENGINEERS SPECIFICATIONS

                                                                                                     FIRST FLOOR CEILING
                                                          CEILING HEIGHT
                                                   2800
                                            250




                                                                                                     FIRST FLOOR PLAN EXISTING


                                                                                                     GROUND FLOOR CEILING
                                                                           PROPOSED CEILING HEIGHT
                                                  2700

                                                                2400




                                                                                                     GROUND FLOOR PLAN


                                                                                                                                 FT    FT         FT           FT   FT   FT   FT   FT     FT          FT         FT




            SUPPORTING FLOOR STRUCTURE
            TO ENGINEER'S SPECIFICATIONS


     TIMBER FLOOR AND SUPPORTING FLOOR
     STRUCTURE TO ENGINEER'S SPECIFICATIONS



CONCRETE FOOTING WITH STEEL POST DESIGN
TO STRUCTURAL ENGINEERS SPECIFICATION'S




                                 WEST SECTIONAL ELEVATION
                       4           SCALE 1:100 @ A3




                                                                                                                                                                                        PROPOSED RESIDENCE No1
                                                                                                                                                                                        11 OPAL STREET COOROY                                 WEST SECTIONAL ELEVATION

Log in to download the original (Approved Plans MCU16-0117.01.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.