3.3 CALCULATION OF POTENTIAL BUSHFIRE INTENSITY
The Potential Bushfire Intensity of each identified sub-unit has been calculated by inputting the site-
specific input parameters discussed in Section 2.1 into the FLAMESOL computer model. FLAMESOL is a
Method 2 assessment methodology under AS3959:2018 and uses industry standard bushfire equations
and allows numerous input variables to be adjusted including fuel loads, fire danger index, site slope and
distance to vegetation. Table 1 details the Potential Bushfire Intensity classes and their corresponding
potential fire-line intensity (kW/m) values as prescribed within Leonard et. al. 2017. The FLAMESOL
modelling used to determine the SPP Potential Bushfire Intensity classes has been included as Appendix
B.
Table 1 – Potential Bushfire Intensity Classes
POTENTIAL BUSHFIRE INTENSITY POTENTIAL FIRELINE INTENSITY
Very High >40,000 kW/m
High 20,000-39,999 kW/m
Medium 4,000 – 19,999 kW/m
Low (no hazard) <4,000 kW/m
Figures 1-3 are presented below and have been prepared as per the above referenced methodology.
AUGUST 2026 BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN Page: 14
380 MCKINNON DRIVE, COOROIBAH