Council archive · source document
Appendix D - Bushfire Assessment · RAL26/0026
| Sub Unit 1 - VHC 9.1 Combined BUSHFIRE HAZARD ASSESSMENT 380 MCKINNON DRIVE COOROIBAH FIGURE 2 HAZARD SUB-UNITS Fire Danger Surface and | Total Fuel Lee retort Potential Index (FDI) | Near Surface Load . . Fuel Load Slope Intensity Intensity 48 21 t/ha 24.2t/ha Odegrees | 15,124kW/m | Medium Sub Unit 2 - VHC 22.1 Combined . . . Fire Danger Surface and | Total Fuel indecone ‘erent ren Index (FDI) | Near Surface Load Slope Intensity Intensity Fuel Load 48 23.4 t/ha 28.4t/ha | Odegrees | 19,777kW/m | Medium Sub Unit 3 - VHC 39.2 Sombined Maximum Potential Potential Fire Danger Surface and | Total Fuel a aa Index (FDI) | Near Surface Load Landscape Fireline Fireline Fuel Load Slope Intensity Intensity 48 4.5 t/ha 5 t/ha 4 degrees 1,464 kw/m Low Sub Unit 4 - VHC 43.6 . Sambined Maximum Potential Potential Fire Danger Surface and | Total Fuel Landscape Fireline Fireline Index (FDI) | Near Surface Load Slope Intensity Intensity Fuel Load 48 Ot/ha Ot/ha O degrees OkW/m Low LEGEND DEVELOPMENT AREA 150m ASSESSMENT BUFFER [0] Mepium PoTENTIAL BUSHFIRE INTENSITY [0 Low Porenriat BUSHFIRE INTENSITY COPYRIGHT © 2026 N
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix D - Bushfire Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.