                                                                                                                                                                                suite 2
                                                                                                                                                                                46 mary street
RL 16.400 LIVING CEILING
                                                                                                                                                                                noosaville qld 4566

                                                                                                                                                                                po box 613
                                                                                                    existing downpipe to be relocated                                           noosa heads qld 4567
                                   LIVING/DINE



                           2,700
                                                                                                                                                                                telephone        07 54473255
                                                                                                                                                                                facsimile        07 54473299
                                                                                                    existing roof over Drying Yard to be removed
RL 13.700 FIRST FLOOR                                                                                                                                                           inf [email protected]

                                                                                                    existing external laundry door to be removed,                               www.ct-design.com.au
                                                                                                    prepare for new wall infill
                                                                                                                                                                                building designer licence 1016347
                           3,000



                                                                                                    existing downpipe to be removed
                                                                       GARAGE
                                     ENTRY       DRYING                                                                                                                         This drawing is to be read in
                                                                                                    existing structural post to be removed                                      conjunction with Engineers Drawings
                                                                                                    existing aluminium screen to remain                                         & Reports.
                                                                                FFL 10.850          shown transparent for clarity
RL 10.700 GROUND FLOOR                                                                                                                                                          Construction to comply with all
                                                                                GARAGE FLOOR
FFL 10.650 APPROX.                                                                                                                                                              relevant SAA & BCA Codes &
                           50




                                                                                                    confirm existing drying yard slab has been built at RL 10.600.
      DRYING YARD                                                                                                                                                               standard Bldg By-law 1975 & as
                                                                                                    80mm below Entry FFL required for proposed lift shaft.
                                                                                                                                                                                amended.
                                                                                                    Note! builder to confirm that existing slab will accomodate lift above
                                                                                                                                                                                Verify all dimensions on site prior to
                                                                                                                                                                                commencement of any works. These
                                                                                                                                                                                drawings are not to be used for
                                                                                                                                                                                scaling. Copyright for design &
                                                                                                                                                                                drawings remain the property of
                                                                                                                                                                                the authors.
                                                 EXISTING WEST ELEVATION                                                                                1:100




                                                                                                                                                                                                 -
                                                                                                                                                                                   NOOSA COUNCIL
                                                                                                                                                                                   APPROVED PLAN
                                                                                                                                                                                    132005.307.01
                                                                                                                                                                                     8 JULY 2024


RL 16.400 LIVING CEILING
                                                                                                    new roof over lift shaft - existing roof sheeting, rafters,
                                                                                                    gutter & fascia to be extended to accomodate
                                                                                                    new timber framed lift shaft to First Floor Level, finish
                                   LIVING/DINE   LIFT
                           2,700




                                                                                                    to match existing
                                                                                                    new location of existing downpipe
                                                                                                                                                                                P5 - REVISED 25.06.2024
                                                                                                    new location of existing downpipe                                           (GFA + Site Cover Added to Sheet WD.101)
RL 13.700 FIRST FLOOR                                                                                                                                                           Project
                                                                                                                                                                                PROPOSED
                                                                                                    proposed location of new lift machine cabinet (beyond),
                                                                                                                                                                                ADDITION OF LIFT
                                                                                                    installed by specialist contractor, refer to manufacturers specifications   Location
                           3,000




                                                 ramp beyond   1,200   GARAGE                                                                                                   30 NOOSA DUNES,
                                     ENTRY                                                          existing aluminium screen (shown transparent for clarity)
                                                                                                                                                                                CASTAWAYS BEACH
                                                                                             new curved block wall, height to match existing,
                                                                                FFL 10.850                                                                                      Client
RL 10.700 GROUND FLOOR                                                                       rendered with paint finish to match existing
FFL 10.650 APPROX.
                                                                                GARAGE FLOOR                                                                                    HUDDART
                           50




                                                                                                                                                                                Drawing Title
      DRYING YARD                                   1,730
                                                  lift shaft                                                                                                                    WEST ELEVATIONS

                                                                                                                                                                                Scale                     Date
                                                                                                                                                                                as shown @A3 2023
                                                                                                                                                                                Drawn By                  Job No:
                                                                                                                                                                                SC                        2317
                                                 PROPOSED WEST ELEVATION                                                                                1:100                   Drawing No.               Issue No.

                                                                                                                                                                                WD.501 P5

Used in these records

About this file

File size
12.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Compiled Approved Plans 132005.307.01.pdf · 12.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.