2020-07-16 SM Agenda - Item 1 - Attachment 3 - Final Noosa Plan 2020 Part 4-6
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn Performance outcomes Acceptable Outcomes
AO16.6
Permanently fixed external screening devices complement the
building's external materials and finishes and may incorporate
solid translucent screens, shutters, perforated panels or trellises
which have a maximum of 50% openings.
Editor's note—refer to figure AP31B
PO17 AO17.1
Development, including mechanical plant, vehicle manoeuvring Communal outdoor recreational facilities including swimming
and communal outdoor recreation uses: pools, spas and sports courts are:
(a) do not have an adverse effect on the amenity enjoyed by (a) setback at least 12 metres from the boundary of land in a
users of adjacent or nearby premises through emission of residential zone and screened by a 5 metre wide buffer
noise, light, fumes or smoke; densely planted with trees and shrubs including species
(b) do not cause unreasonable disturbance to local fauna from 1 metre to 8 metres in height; or
through light or smoke emissions. (b) located internally to the arrangement of buildings on the
site; and
(c) not used between the hours of 9:00pm and 6:30am the
following day
AO17.2
For a lit sports court:
(a) the court is located at least 60 metres from the external wall
of an existing or approved dwelling on adjoining or nearby
premises (as measured from the centre line of the court);
and
(b) the vertical illumination resulting from direct, reflected or
other incidental light emanating from the site does not
exceed 8 lux when measured at any point 1.5 metres
outside the boundary and at any level from ground level
upward; and
(c) any flood lighting is restricted to the types that give no
upward component of light where mounted horizontally (i.e.
a full cut off luminare)
AO17.3
Mechanical plant is:
(a) located at least 2 metres from side or rear property
boundary;
(b) where located at ground level, screened by fencing 1.5
metres in height or dense vegetation of at least 1.5 metres
in width incorporating grouped trees and shrubs with
maximum separation distance of 1 metre measured from
the centre of the plant;
(c) where located above ground level, enclosed or screened
such that it is not visible from the street frontage nor
adjoining properties; and
(d) visually integrated into the line and plane of the building
and roof design and does not project beyond the height or
width of the building when viewed from the street and
adjoining properties.
Editor’s Note— Mechanical plant includes generators, motors,
compressors and pumps such as airconditioning or pool
equipment.
NOOSA PLAN 2020 Page 30 of 48
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.