  Performance outcomes                                              Acceptable Outcomes
                                                                    AO16.6
                                                                    Permanently fixed external screening devices complement the
                                                                    building's external materials and finishes and may incorporate
                                                                    solid translucent screens, shutters, perforated panels or trellises
                                                                    which have a maximum of 50% openings.

                                                                    Editor's note—refer to figure AP3­1B
  PO17                                                              AO17.1
  Development, including mechanical plant, vehicle manoeuvring      Communal outdoor recreational facilities including swimming
  and communal outdoor recreation uses:                             pools, spas and sports courts are:
  (a)    do not have an adverse effect on the amenity enjoyed by    (a)    setback at least 12 metres from the boundary of land in a
         users of adjacent or nearby premises through emission of          residential zone and screened by a 5 metre wide buffer
         noise, light, fumes or smoke;                                     densely planted with trees and shrubs including species
  (b)    do not cause unreasonable disturbance to local fauna              from 1 metre to 8 metres in height; or
         through light or smoke emissions.                          (b)    located internally to the arrangement of buildings on the
                                                                           site; and
                                                                    (c)    not used between the hours of 9:00pm and 6:30am the
                                                                           following day

                                                                    AO17.2
                                                                    For a lit sports court:
                                                                    (a)    the court is located at least 60 metres from the external wall
                                                                           of an existing or approved dwelling on adjoining or nearby
                                                                           premises (as measured from the centre line of the court);
                                                                           and
                                                                    (b)    the vertical illumination resulting from direct, reflected or
                                                                           other incidental light emanating from the site does not
                                                                           exceed 8 lux when measured at any point 1.5 metres
                                                                           outside the boundary and at any level from ground level
                                                                           upward; and
                                                                    (c)    any flood lighting is restricted to the types that give no
                                                                           upward component of light where mounted horizontally (i.e.
                                                                           a full cut off luminare)

                                                                    AO17.3
                                                                    Mechanical plant is:
                                                                    (a)    located at least 2 metres from side or rear property
                                                                           boundary;
                                                                    (b)    where located at ground level, screened by fencing 1.5
                                                                           metres in height or dense vegetation of at least 1.5 metres
                                                                           in width incorporating grouped trees and shrubs with
                                                                           maximum separation distance of 1 metre measured from
                                                                           the centre of the plant;
                                                                    (c)    where located above ground level, enclosed or screened
                                                                           such that it is not visible from the street frontage nor
                                                                           adjoining properties; and
                                                                    (d)    visually integrated into the line and plane of the building
                                                                           and roof design and does not project beyond the height or
                                                                           width of the building when viewed from the street and
                                                                           adjoining properties.

                                                                    Editor’s Note— Mechanical plant includes generators, motors,
                                                                    compressors and pumps such as air­conditioning or pool
                                                                    equipment.



NOOSA PLAN 2020                                                                                                                   Page 30 of 48
Log in to download the original file

2020-07-16 SM Agenda - Item 1 - Attachment 3 - Final Noosa Plan 2020 Part 4-6(PDF, 9MB).pdf · 9.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.