Original source · versioned page text
Medium Density Residential Code
Performance Outcomes Acceptable Outcomes
light emanating from the site does not
exceed 8 lux when measured at any
point 1.5 metres outside the boundary
and at any level from ground level
upward; and
3. any floodlighting is restricted to the
types that give no upward component
of light were mounted horizontally (i.e.
a full cut off luminaire).
AO21.3 Complies:
Mechanical plant is- Mechanical plant and equipment will be suitably
located to ensure that it does not adversely impact
1. located at least 2 metres from the side
adjoining premises or is visible from the street.
or rear property boundaries;
2. where located at ground level,
screened by fencing 1.5 metres in
height or dense vegetation of at least
1.5 metres in width incorporating
grouped trees and shrubs with a
maximum separation distance of 1
metre measured from the centre of the
plant;
3. where located above ground level,
enclosed or screened such that it is
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.