Appendix B - Bushfire Hazard Assessment
3.3 CALCULATION OF POTENTIAL BUSHFIRE INTENSITY
The Potential Bushfire Intensity of each identified sub-unit has been calculated by inputting the site-
specific input parameters discussed in Section 2.1 into the FLAMESOL computer model. FLAMESOL uses
industry standard bushfire equations and allows numerous input variables to be adjusted including fuel
loads, fire danger index, site slope and distance to vegetation. Table 1 details the Potential Bushfire
Intensity classes and their corresponding potential fire-line intensity (KW/m) values as prescribed within
Leonard et. al. 2017.
Table 1 – Potential Bushfire Intensity Classes
POTENTIAL BUSHFIRE INTENSITY POTENTIAL FIRELINE INTENSITY
Very High >40,000 kW/m
High 20,000-39,999 kW/m
Medium 4,000 – 19,999 kW/m
Low <4,000 kW/m
Figures 1-3 are presented below and have been prepared as per the above referenced methodology.
NOVEMBER 2022 BUSHFIRE HAZARD ASSESSMENT Page: 13
157 LAWNVILLE ROAD, BLAK MOUNTAIN
See the original