                                                                                   FLUSH FITTING REMOVABLE
                                                                                   ACCESS PANEL TO SERVICE
                                                                                   AC UNIT IN CEILING


                                                                                                                                                                                                                                2150
                TH
            R
           O                                                                       AC UNIT AND GRILLE IN
                                                                                                                                                                                                                               STEP
       N                                             REPAIR AND MAKE GOOD          BULKHEAD OVER
                                                                                                                                                                                           REMOVABLE ACCESS PANEL
                                                                                                                                                                                           TO SERVICE AC UNIT IN ROBE
                                                     EXISTING FLAT
                                                     PLASTERBOARD CEILING AS                                               ENS                                                             SIZE TO AC INSTALLERS
                                                     REQUIRED FOR NEW                                                      2120                                                            REQUIREMENTS
                                                                                   EXTEND 2120 LOW
                                                     ELECTRICAL FITTINGS,          PLASTERBOARD CEILING TO                                                                                 AC UNIT AND GRILLE IN
                                                     FIXTURES AND WALLS            ENTIRE ENSUITE                                                              2140                        NEW PLASTERBOARD
                                                     2430                                                                                                                                  BULKHEAD TO LINE WITH
                                                                                                                                                               BATH                        WINDOW HEAD
                                                                           BED 2                                                                                                           REPAIR AND MAKE GOOD
                                                                                                           STEP                                 STEP                  STEP                 EXISTING FLAT
                                                                                                                                                                                           PLASTERBOARD CEILINGS


                                                                                                                                                                   STEP                          2470

                                                     NEW SLIMLINE CONTINUOUS                                                                                                                     BED 1
                                                     CEILING CURTAIN TRACK AS
                                                     SCHEDULED                                                     DN
                                                                                                                     REPAIR AND MAKE GOOD                   2470
                                                                                                                     EXISTING RAKED
                                                                                                                     PLASTERBOARD CEILING                   ENTRY
                                                     NEW PLASTERBOARD                                                                                REPAIR AND MAKE
                                                     CEILING BULKHEAD BEHIND
                                                     ROBE DOORS
                                                                                                   STEP
                                                                                                    2330
                                                                                                                                                     GOOD EXISTING FLAT
                                                                                                                                                     PLASTERBOARD                                                           FIRST FLOOR
                                                                                                                                                     CEILING
                                                                                                                                                                                                                 2          1 : 50
                                                                                                                                                                                                GENERAL NOTES:
                                                                                                                                                                                                - CEILING HEIGHTS ARE FROM INTERNAL FINISHED FLOOR LEVEL
                                                                                                                                                                                                - ALL DIMENSIONS TO BE CONFIRMED ON SITE WITH EXISTING, CONTACT
                                                             RETRACTABLE FABRIC AWNING                                                                                                          FRANK MACCHIA IF ANY DISCREPANCIES OCCUR
                                                             OVER AS SCHEDULED                                                                                                                  - REPAIR AND MAKE GOOD EXISTING SHEETED CEILINGS AND CEILING/ WALL
                                                                                                                                                                                                JUNCTIONS. ENSURE EXISTING FIRE RATING IS RETAINED
                                                                                                                                              2410        EXISTING CONDUITS AND                 - REPAIR AND MAKE GOOD ALL ACOUSTIC INSULATION TO CEILINGS AND
                                                                                                                                                          AC PIPES CONCEALED                    PIPEWORK. ENSURE EXISTING ACOUSTIC RATING IS RETAINED.
                                                                                                                                                          WITHIN FOLDED                         - INTERNAL CORNICE TO PLASTERBOARD CEILINGS TO BE RONDO P50
                                                                                                                                                          POWDERCOATED                          SHADOW RECESS TO DETAIL. CORNICE TO EXTEND UP SIDES OF BULKHEADS
                                                                                                                                                          ALUMINIUM BULKHEAD/                   AND TO TOP OF ALL FULL HEIGHT WINDOWS.
                                                                                                                                                          BEAM                                  - REFER TO FINISHES SCHEDULE FOR PAINTED SURFACE TREATMENTS
                                                                                                                                                                                                - AIR CONDITIONING CONTRACTOR TO LIASE WITH BUILDER AND MACCHIA TO
                                                                                                                                                                                                LOCATE ACCESS PANELS AS REQUIRED TO SERVICE AIR CONDITIONING UNITS
                                                                                                                                                                                                HOUSED WITHIN BULKHEADS AND CEILING SPACES.
                                                             TAKE UP EXISTING TIMBER BOARD                                                                                                      - POWDERCOATED LINEAL AIR CONDITIONING GRILLE AS DETAILED REFER TO
                                                             CEILING LINING FOR NEW FLAT                                                                                                        FINISHES SCHEDULE FOR COLOUR AND TO DETAILS FOR DESIGN
                                                             PLASTERBOARD CEILING TO                                                                                                            - INSULATION TO CEILINGS AND UNDER SUSPENDED FLOORS AS SCHEDULED,
                                                             DINING AND KITCHEN                                                                                                                 REFER TO BERS CERTIFICATE FOR REQUIRED R VALUES.
           MOTORISED
           RETRACTABLE DROP                                  2410                                                                                                                               A/C AIR CONDITIONING SYSTEM
           DOWN TELEVISION                                                                    DINING                       KITCHEN
           SCREEN AND                                                                                                                                                                           - A/C REGISTERS AND POSITIONS ARE INDICATIVE ONLY
           PROJECTOR RECESSED                                                                                                                                                                   - MECHANICAL CONTRACTOR TO LIASE WITH BUILDER/ MACCHIA TO DETERMINE
           INTO CEILING/ FLOOR                                                                                                                                                                  FINAL POSITION AND EXTENT OF GRILLES AND AC UNITS REQUIRED
                                                                                                                                                          BIFOLD DOOR TRACKS                    - BUILDER TO ALLOW FOR THE CONSTRUCTION AND FINISHING OFF OF THE
           CONFIRM BUILD IN                                                                                                                               RECESSED INTO
           DIMENSIONS WITH                                                                                                                                                                      REQUIRED BULKHEADS TO HOUSE AC UNITS- ADJUSTMENTS TO JOINERY DUE
                                                                                                                                                          PLASTERBOARD CEILING                  TO AC BULKHEADS MAYBE REQUIRED AFTER FINAL EXTENT DETERMINED
           MANUFACTURER
                                                      STEP                                                               STEP
                                       LIVING                                                                                                                                                   MECHANICAL EXHAUST
                                                                                                                                                          CEILING STEP IN LAUNDRY               - ALLOW TO LOCATE ON SITE IN CO-ORDINATION WITH INTERIOR DETAILS AND
                                       VOID OVER                                                                           DN                             BEHIND BIFOLD DOORS                   WITHIN CEILING/ WALL SPACES ALLOW TO VENT TO EXTERNAL WALL AS
                                                                            STEP                                                                                                                REQUIRED
                                                                                                                                   LDRY                   REPAIR AND MAKE GOOD                  - ALL MECHANICAL EXHAUSTS ARE TO BE SEALED TO EXTERNAL GRILLES TO
                                       PLASTERBAORD CEILING TO EXTENDED                                                                                   EXISTING RAKED
                                       EXISTING STEEL AND TIMBER FRAMED                                                                                                                         MEET ENERGY EFFICIENCY REQUIREMENTS
                                                                                                                                                          PLASTERBOARD TO
                                       FLOOR OVER TO ENGINEERS DETAIL                                                                                     UNDERSIDE OF STAIRS
                                       AC UNIT IN FLOOR/ BASE OF ROBE
                                       OVER FOR GRILLE TO LIVING CEILING                                          STEP            VOID OVER
                                                                                                                                                                             GROUND FLOOR
                                                                                                                                                                      1         1 : 50
                                                                                                                                                                                                                                               B   APPROVALS, BODY CORP
                                                                                                                                                                                                                                                   NOTES
                                                                                                                                                                                                                                               A APPROVALS ISSUE
                                                                                                                                                                                                                                                                          09.01.2021

                                                                                                                                                                                                                                                                          11.12.2020
                                                                                                                                                                                                                                               no.       description         date


HINCKFUSS RESIDENCE                                                   REFLECTED CEILING PLANS                                                                                                                    date           21.10.2020
                                                                                                                                                                                                                                               WD 5.00                    B
                                                                                                                                                                          e. [email protected]
                                                                                                                                                                                                                 drawn by             Author
LITTLE COVE COURT- APARTMENT 8, 2 PANDANUS STREET, NOOSA HEADS WORKING DRAWINGS                                                                                           p. 0447 494 202
                                                                                                                                                                                                                 checked by      Checker       scale @ a3            As indicated
                                                                                                                                                                          a. p.o.box 365, noosaville, qld 4566


[OCR of page images]
 

 

MOTORISED

FLUSH FITTING REMOVABLE
ACCESS PANEL TO SERVICE
AC UNIT IN CEILING

AC UNIT AND GRILLE IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETRACTABLE DROP
DOWN TELEVISION

SCREEN AND

PROJECTOR RECESSED
INTO CEILING/ FLOOR
CONFIRM BUILD IN
DIMENSIONS WITH

MANUFACTURER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

|
REPAIR AND MAKE GOOD BULKHEAD OVER |
EXISTING FLAT | ENS
PLASTERBOARD CEILING AS |
REQUIRED FOR NEW EXTEND 2120 LOW
ELECTRICAL FITTINGS, PLASTERBOARD CEILING TO |
FIXTURES AND WALLS ENTIRE ENSUITE
BED 2 N
STEP STEP STEP
~
~~
~ ~
N STEP
NEW SLIMLINE CONTINUOUS
CEILING CURTAIN TRACK AS
SCHEDULED DN
REPAIR AND MAKE GOOD 2470
EXISTING RAKED ENTRY
| PLASTERBOARD CEILING
NEW PLASTERBOARD REPAIR AND MAKE
CEILING BULKHEAD BEHIND | STEP GOOD EXISTING FLAT
ROBE DOORS 2330 PLASTERBOARD
CEILING
RETRACTABLE FABRIC AWNING
OVER AS SCHEDULED
— 2410] —— EXISTING CONDUITS AND
AC PIPES CONCEALED
WITHIN FOLDED
ee POWDERCOATED
eee eer TT ALUMINIUM BULKHEAD/
BEAM
TAKE UP EXISTING TIMBER BOARD
CEILING LINING FOR NEW FLAT
PLASTERBOARD CEILING TO
DINING AND KITCHEN
DINING KITCHEN
BIFOLD DOOR TRACKS
RECESSED INTO
PLASTERBOARD CEILING
LIVING STEP STEP y~* |
>. ~ pf FE CEILING STEP IN LAUNDRY
VOID OVER stepl ~ DN —————> fj BEHIND BIFOLD DOORS
-—_tbRY_ >
PLASTERBAORD CEILING TO EXTENDED 1 | BRISTING HANED. GOOD
EXISTING STEEL AND TIMBER FRAMED PLASTERBOARD TO
FLOOR OVER TO ENGINEERS DETAIL————}tf# =“ |
7 UNDERSIDE OF STAIRS
AC UNIT IN FLOOR/ BASE OF ROBE /
OVER FOR GRILLE TO LIVING CEILING | STEP| VOID OVER
|

 

 

_. GROUND FLOOR

1)

~ STEP
REMOVABLE ACCESS PANEL
TO SERVICE AC UNIT IN ROBE
SIZE TO AC INSTALLERS

REQUIREMENTS

AC UNIT AND GRILLE IN

NEW PLASTERBOARD
BULKHEAD TO LINE WITH
WINDOW HEAD —————"

REPAIR AND MAKE GOOD
EXISTING FLAT
PLASTERBOARD CEILINGS

 

 

BED 1
7
-, FIRST FLOOR
GENERAL NOTES:

 

- CEILING HEIGHTS ARE FROM INTERNAL FINISHED FLOOR LEVEL

- ALL DIMENSIONS TO BE CONFIRMED ON SITE WITH EXISTING, CONTACT
FRANK MACCHIA IF ANY DISCREPANCIES OCCUR

- REPAIR AND MAKE GOOD EXISTING SHEETED CEILINGS AND CEILING/ WALL
JUNCTIONS. ENSURE EXISTING FIRE RATING IS RETAINED

- REPAIR AND MAKE GOOD ALL ACOUSTIC INSULATION TO CEILINGS AND
PIPEWORK. ENSURE EXISTING ACOUSTIC RATING IS RETAINED.

- INTERNAL CORNICE TO _PLASTERBOARD CEILINGS TO BE RONDO P50
SHADOW RECESS TO DETAIL. CORNICE TO EXTEND UP SIDES OF BULKHEADS
AND TO TOP OF ALL FULL HEIGHT WINDOWS.

- REFER TO FINISHES SCHEDULE FOR PAINTED SURFACE TREATMENTS.

- AIR CONDITIONING CONTRACTOR TO LIASE WITH BUILDER AND MACCHIA TO.
LOCATE ACCESS PANELS AS REQUIRED TO SERVICE AIR CONDITIONING UNITS
HOUSED WITHIN BULKHEADS AND CEILING SPACES.

- POWDERCOATED LINEAL AIR CONDITIONING GRILLE AS DETAILED REFER TO
FINISHES SCHEDULE FOR COLOUR AND TO DETAILS FOR DESIGN

- INSULATION TO CEILINGS AND UNDER SUSPENDED FLOORS AS SCHEDULED,
REFER TO BERS CERTIFICATE FOR REQUIRED R VALUES.

A/C AIR CONDITIONING SYSTEM

- AIC REGISTERS AND POSITIONS ARE INDICATIVE ONLY

- MECHANICAL CONTRACTOR TO LIASE WITH BUILDER/ MACCHIA TO DETERMINE
FINAL POSITION AND EXTENT OF GRILLES AND AC UNITS REQUIRED

- BUILDER TO ALLOW FOR THE CONSTRUCTION AND FINISHING OFF OF THE
REQUIRED BULKHEADS TO HOUSE AC UNITS- ADJUSTMENTS TO JOINERY DUE
TO AC BULKHEADS MAYBE REQUIRED AFTER FINAL EXTENT DETERMINED

MECHANICAL EXHAUST

- ALLOW TO LOCATE ON SITE IN CO-ORDINATION WITH INTERIOR DETAILS AND
WITHIN CEILING/ WALL SPACES ALLOW TO VENT TO EXTERNAL WALL AS
REQUIRED

- ALL MECHANICAL EXHAUSTS ARE TO BE SEALED TO EXTERNAL GRILLES TO
MEET ENERGY EFFICIENCY REQUIREMENTS

 

 

 

 

 

 

 

 

 

B |APPROVALS, BODY CORP 09.01.2021

 

 

 

 

 

 

\ _/ 1:50 A APPROVALS ISSUE 11.12.2020
HINCKFUSS RESIDENCE REFLECTED CEILING PLANS ‘ius Ss WD 5.00 B

LITTLE COVE COURT- APARTMENT 8, 2 PANDANUS STREET, NOOSA HEADS)

 

WORKING DRAWINGS

 

e. [email protected]
p. 0447 494 202
a. p.0.box 365, noosaville, qld 4566

 

As indicated

 

 

checked by Checker |scale @ a3

 

 

Log in to download the original (20200466 - REVISED PLANS AS OF 9 FEB 2021.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.