20200466 - REVISED PLANS AS OF 9 FEB 2021.pdf

of 15

Page text read automatically using OCR, there may be inaccuracies

                                                                                                                                                                                                                                          AC OVER




                                                                                                                                                                   EF
                                                              TV                                                                                                                                                                    850
                                                                                                                                 0                    EF
                                                                                                                              140
                                                                                                                                                                               BATH
                                                                                                                              AC OVER
                                                                                                                                            ENS

                                                                              BED 2                                              0
                                                                                                                              140
                                                                                                                                                                       0
                                                                                                                                                                    140
                                                                                                                                                                                                                            BED 1
                                                                                                                              MSB



                                                                                                                    D

                                                                                                               S                                                                                 D
                                                                                                                                            900


                                                                                                                                                                           S                                     S
                                                                                                                                                                           ENTRY
                                                                                                                                     3W
                                                                   VOID                                                                                                        3W


                                                                                                                                          TO
                                                                                                                                          GROUND
                                                                                                                                          FLOOR




                 ELECTRICAL- FIRST FLOOR
     1            1 : 50

   ELECTRICAL LEGEND
              ELECTRICAL SWITCH LOCATION                                           - SINGLE POWER POINT                                   GENERAL NOTES

              - RECESSED LOW VOLTAGE CEILING LED DOWNLIGHT                         - DOUBLE POWER POINT                                   - ALL LOW GPO'S 100MM OFF FLOOR
                                                                                                                                          - ALL LIGHT SWITCHES 1000MM OFF FLOOR
              - EXTERNAL GRADE SUITABLE, WALL MOUNTED LIGHT                                                                               - ALLOW FOR REVERSE CYCLE SPLIT SYSTEM AIR
              600 HIGH FROM FLOOR UNLESS NOTED OTHERWISE                  C6       - C6 DATA CABLE & POINT                                CONDITIONING, UNITS CONCEALED WITHING BULKHEADS AS
                                                                                                                                          DETAILED, REFER TO REFLECTED CEILING PLANS FOR UNIT
              - SURFACE MOUNTED LED WALL LIGHT                                                                                            LOCATIONS. ZONE 1- BED 1, ZONE 2- BED 2, ZONE 3- OFFICE
                                                                             USB   - USB CHARGER WITH DOUBLE POWER POINT COMBO            (STANDARD WALL MOUNTED SPLIT SYSTEM UNIT), ZONE 4-
              - LOW VOLTAGE ADJUSTABLE ANGLE GARDEN LIGHT                                                                                 BED 3, ZONE 5- ENSUITE, ZONE 6- LIVING/ DINING. EXTERNAL
              ON SPIKE WITH AUTOMATIC TIMER AND SUNDOWN                                                                                   CONDENSOR UNITS LOCATED UNDER ENSUITE TO
              SENSOR                                                         TV    - TELEVISION POINT CABLE AND FREE TO AIR               UNDERCROFT
                                                                                                                                          - ELECTRICIAN TO GROUP WHERE APPROPRIATE LED
              - RECESSED LOW VOLTAGE FLOOR LIGHT                                                                                          FITTINGS ONTO REQUIRED NUMBER OF DRIVERS AND TO
                                                                             T
                                                                                   - TELEPHONE POINT                                      ALLOW FOR POSSIBLE ADDITINAL FUTURE LIGHT FITTINGS
              - RECESSED CONTINUOUS LENGTH STRIP LED LOW                                                                                  - BACK TO BASE INTRUDER ALARM SYSTEM WITH PET
              VOLTAGE LIGHT IN RECESSED POWDERCOATED                         WP - WATERPROOF FIXTURE                                      FRIENDLY INTERNAL MOTION SENSORS, AUDIBLE ALARM AND
              ALUMINIUM CHANNEL WITH DIFFUSER                                                                                             EXTERNAL STROBE LIGHT
                                                                             EF - EXHAUST FAN- WALL MOUNTED                               - 3 PHASE MAINS POWER TO BE PROVIDED FROM ROAD
              - CEILING PENDANT LIGHT
                                                                          MSB      - SWITCH BOARD- REPLACE EXISTING BOARD TO              AIR CONDITIONING NOTES
      S       - SMOKE DETECTOR HARD WIRED AND                                      RECESS INTO WALL
              INTERCONNECTED TO AUSTRALIAN STANDARDS AND                                                                                  - A/C REGISTERS AND POSITIONS ARE INDICATIVE ONLY -
              QUEENSLAND REQUIREMENTS                                                                                                     MECHANICAL CONTRACTOR TO LIASE WITH BUILDER / CLIENT
                                                                                   - INTERCOM                                             TO DETERMINE FINAL POSITION AND EXTENT OF GRILLES AND
              - LOW VOLTAGE LED ADJUSTABLE ANGLE WALL TWIN                                                                                A/C UNITS REQUIRED.
              SPOT LIGHT                                                                                                                  - BUILDER TO ALLOW FOR THE CONSTRUCTION AND FINISHING
                                                                                                                                          OFF OF REQUIRED BULKHEADS TO HOUSE A/C UNITS.
              - LOW VOLTAGE SURFACE MOUNTED CEILING LED                            - 1500 DIA. CEILING FAN                                - FINAL EXTENT OF BUKHEADS TO BE DETERMINED ONSITE
              DIRECTIONAL LIGHT                                                                                                           WITH A/C CONTRACTOR / BUILDER AND CLIENT.
                                                                      1500                                                                                                                                                                                       B   APPROVALS, BODY CORP   09.01.2021
          D                                                                                                                               - ADJUSTMENTS TO JOINERY UNITS DUE TO A/C BULKHEADS
                                                                                                                                                                                                                                                                     NOTES
              - LIGHT DIMMER COMPATIBLE WITH LED LIGHTS                                                                                   AND ACCESS PANELS MAYBE REQUIRED AFTER FINAL
                                                                                                                                                                                                                                                                 A APPROVALS ISSUE          11.12.2020
                                                                                                                                          EXTENT DETERMINED.
                                                                                                                                                                                                                                                                 no.       description         date


HINCKFUSS RESIDENCE                                                                          ELECTRICAL PLAN                                                                                                                       date             21.10.2020
                                                                                                                                                                                                                                                                 WD 7.01                    B
                                                                                                                                                                                            e. [email protected]
                                                                                                                                                                                                                                   drawn by            Author
LITTLE COVE COURT- APARTMENT 8, 2 PANDANUS STREET, NOOSA HEADS WORKING DRAWINGS                                                                                                             p. 0447 494 202
                                                                                                                                                                                                                                   checked by        Checker     scale @ a3            As indicated
                                                                                                                                                                                            a. p.o.box 365, noosaville, qld 4566


[OCR of page images]
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC OVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

—_ eo _ O
= ee
wo 7 Z
CQVER /
_ ENS
~
/ \ C )
FT
~~ 7 / A
/ ~~ WP /
/ ry Le
/ “I
/ \
/ \
/ O
Jo
| 7
aw)
sl
rol | [|
GROUND K DN | KT
FLOOR [ p07
_.. ELECTRICAL- FIRST FLOOR
1
S74 1:50
X ELECTRICAL SWITCH LOCATION W  - SINGLE POWER POINT GENERAL NOTES
©) - RECESSED LOW VOLTAGE CEILING LED DOWNLIGHT YJ “DOUBLE POWER POINT - ALL LOW GPO'S 100MM OFF FLOOR
~ - ALL LIGHT SWITCHES 1000MM OFF FLOOR
- EXTERNAL GRADE SUITABLE, WALL MOUNTED LIGHT - ALLOW FOR REVERSE CYCLE SPLIT SYSTEM AIR
fm 600 HIGH FROM FLOOR UNLESS NOTED OTHERWISE cs) - C6 DATA CABLE & POINT CONDITIONING, UNITS CONCEALED WITHING BULKHEADS AS
DETAILED, REFER TO REFLECTED CEILING PLANS FOR UNIT
dq) - SURFACE MOUNTED LED WALL LIGHT LOCATIONS. ZONE 1- BED 1, ZONE 2- BED 2, ZONE 3- OFFICE
USB) - USB CHARGER WITH DOUBLE POWER POINT COMBO (STANDARD WALL MOUNTED SPLIT SYSTEM UNIT), ZONE 4-
©) ~ LOW VOLTAGE ADJUSTABLE ANGLE GARDEN LIGHT BED 3, ZONE 5- ENSUITE, ZONE 6- LIVING/ DINING. EXTERNAL
“J ON SPIKE WITH AUTOMATIC TIMER AND SUNDOWN CONDENSOR UNITS LOCATED UNDER ENSUITE TO
SENSOR TV] - TELEVISION POINT CABLE AND FREE TO AIR UNDERCROFT
- ELECTRICIAN TO GROUP WHERE APPROPRIATE LED
©  - RECESSED LOW VOLTAGE FLOOR LIGHT FITTINGS ONTO REQUIRED NUMBER OF DRIVERS AND TO
<L - TELEPHONE POINT ALLOW FOR POSSIBLE ADDITINAL FUTURE LIGHT FITTINGS
mmm - RECESSED CONTINUOUS LENGTH STRIP LED LOW - BACK TO BASE INTRUDER ALARM SYSTEM WITH PET
VOLTAGE LIGHT IN RECESSED POWDERCOATED WP - WATERPROOF FIXTURE FRIENDLY INTERNAL MOTION SENSORS, AUDIBLE ALARM AND
ALUMINIUM CHANNEL WITH DIFFUSER EXTERNAL STROBE LIGHT
1 - EXHAUST FAN- WALL MOUNTED - 3 PHASE MAINS POWER TO BE PROVIDED FROM ROAD
- CEILING PENDANT LIGHT
- SWITCH BOARD- REPLACE EXISTING BOARD TO AIR CONDITIONING NOTES
- SMOKE DETECTOR HARD WIRED AND RECESS INTO WALL
INTERCONNECTED TO AUSTRALIAN STANDARDS AND - AC REGISTERS AND POSITIONS ARE INDICATIVE ONLY -
QUEENSLAND REQUIREMENTS MECHANICAL CONTRACTOR TO LIASE WITH BUILDER / CLIENT
- INTERCOM TO DETERMINE FINAL POSITION AND EXTENT OF GRILLES AND
) = LOW VOLTAGE LED ADJUSTABLE ANGLE WALL TWIN A/C UNITS REQUIRED.
SPOT LIGHT - BUILDER TO ALLOW FOR THE CONSTRUCTION AND FINISHING
OFF OF REQUIRED BULKHEADS TO HOUSE A/C UNITS.
 - LOW VOLTAGE SURFACE MOUNTED CEILING LED - 1500 DIA. CEILING FAN - FINAL EXTENT OF BUKHEADS TO BE DETERMINED ONSITE
7 DIRECTIONAL LIGHT WITH A/G CONTRACTOR / BUILDER AND CLIENT.
D - ADJUSTMENTS TO JOINERY UNITS DUE TO A/C BULKHEADS B ROTES TS: BODY CORP [09.01.2021
+ - LIGHT DIMMER COMPATIBLE WITH LED LIGHTS AND ACCESS PANELS MAYBE REQUIRED AFTER FINAL
EXTENT DETERMINED. [A |APPROVALS ISSUE 11.12.2020
no. description date
FRANKMIACCHIA —acte 21.10.2020
HINCKFUSS RESIDENCE ELECTRICAL PLAN TUT WD 7.01 B
LITTLE COVE COURT- APARTMENT 8, 2 PANDANUS STREET, NOOSA HEADS, WORKING DRAWINGS powreazoe sown “ner
URT- ’ U ’ e pi pon 36% noosavile, qld 4566 checked by Checker |scale @ a3 As indicated

 

 

 

 

 

 

Log in to download the original (20200466 - REVISED PLANS AS OF 9 FEB 2021.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.