Council archive · source document
07/0965 - Revised documentation for application as requested [As Published] · 132007.965
MITCHELLDESIGN The design provides for a series of levels stepping down the site but even with this approach there are some instances where a roof pitched from normal ceiling levels will broach the height limit. We therefore request consideration of relaxation of the roof pitch requirement to 3 degrees. It is noted when measuring the height limit, the information provided by Donald A Colston, Surveyor in Drawing 04168-1 has been relied on. A copy of this drawing is submitted with the application. The height indicated is compared with the interpretation of the original natural ground level as provided by surveyor although there is fittie difference in most instances between the original and current levels. There is an existing house on the site which breaches the height limit at the front and also at the rear. Demolition of the Existing House The existing house is to be demolished. Its adaptation has been investigated but its layout, its condition and the general quality of its construction is neither suitable to clients’ needs nor readily or for that matter economically adaptable, The specific difficulties are the number of levels and the planning of internal spaces which do not allow the provision for adaptability possible. Removal is currently being investigated although preliminary advice indicates that this is difficult for the sorts of reasons which make it impossible to adapt. Advice obtained by the client indicates that a significant proportion of the material and fittings in the house is likely to be able to be recycled. Overlays The Noosa Plan identifies that the property does not trigger Biodiversity (environmental protection) or Natural Resources (coastal protection) Overlays. The Natural Hazard Overlay, however, determines that the property lies within a Medium Bushfire Hazard Area. The Building Code of Australia contains provisions applying to building in bushfire prone areas. Building certification will require that the building be constructed to reduce ember attack. To comply with AS3959-1999, the use of fire retardant building materials, door seals, ridge seals, sealed roof/wall junctions and screened window openings, vents and weepholes may need to be provided. This will be addressed in the next stage of design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0965 - Revised documentation for application as requested [As Published]Related documentApplication case desk ↗
About this file
- File size
- 962 KB (small file)
- File type
No other editions are linked here.