Council archive · source document
07/2606 - Response to Information Request - Part 1 [As Published] · 132007.2606
B
A
6,800
35.479 m 17deg. 30'
250 4,400 250
450
3,60
D.P
1,80 0
0
12 06
3 DEG FALL
1,60
7 open'g
POOL BELOW
Fascia & Gutter
D.P
190
frameless glass
balustrading
BED RM 2
24-28SD
600
1830 AWN
4,500 o/ha
ng
(CPT)
BALC
4,000
ng
o/ha
5 DE
5,07
6
G FA
LL 2 70
580
70 2,740 250
600
600 6,580
250
6,00
0
770
3x 24 06 GLV
5,50
70
0 2x 18 045 GLV
OBSCURED
SEAHORSE PL.
shwr
ENS
20.000 m
20.000 m
1,754
face fixed framelss glass 250
ROBE
250
balustrade to 1m min. height
V
093 hidden cistern
6 GL
6 GL
V
6,380
240
BALCONY 1 24 30 FG
/GLV 820 wall mounted basin
1 DEG. FALL
24 24
low wall behind
SLAB
FG/GLV
LANDING
1 DEG. FALL
0 SD
250 107deg 30'
107deg 30'
6
1831 FG
5,00
SLAB
243
MASTER s/steel h/rail
VOID 690 1,270 VOID
C BED RM C
V
6 GL
(CPT) 18 10 24 08
FG butt open'g
240
70
2406 GLV
1 2 3 4 5 6 7 8 9 101112131415161718
D.P
70
250
18 10
90 1,600
obscure
250
1,100
FG butt flat roof over
LANDING
820
shwr
820
(CPT) entry gate
820
70
70 520
LINEN
24 36 open'g
D.P
2436 GLV
ROOF timber wall
ENS
4,700
24 16
BED RM 3
1827 AWN
4,470
3 DEG. FALL
1 DEG. 3,720 1,500 400x200mm corbelling
250 1,820
SGD
W.I.ROBE
N
FALL shwr (CPT) over garage door belowroof
3,300
LIBRARY
5 AW
(CPT) ENS
770
(CPT)
151
door built-in
wc to cabinetry
770
250 450
1812 GLV
D.P 1809 GLV D.P 1530 AWN
250
250
250
obscure wall mounted basin
low wall behind
400 x 150mm hood hidden cistern BOX GUTTER
250 3,290 70 3,600 35.479 m 17deg. 30' Parapet 3500 H
20
2,097 250 8,150 70 700 90 3,370 250
B
A
PROPOSED FIRST FLOOR PLAN
SCALE 1 : 100
LEGEND : 0 5m
awn awning hp hot plate
cas casement rh range hood
fg fixed glass dw dish washer
glv glass louvre mw micro-wave
m mullion ref refridgerator
sd sliding door wm washing machine
dp down pipe dry dryer
ubo under bench oven FP Fire Place
pty pantry WC Water Closet (Toilet)
cup'd cupboard
NOTES :
Where notes refer to 'selected' please refer to Architects Specification
Where notes refer to 'future detail' please refer to Architects Specification
unless location indicated otherwise.
All work to comply with Building Code of Australia and its most current
amendments, this construction being of class 1.
Before commencing construction, all dimensions, existing levels,
finished levels & site services are to be verified are to be verified.
Architectural drawings are to be read in conjunction with any
associated consultants drawings.
FIGURED DIMENSIONS TO TAKE PRECEDENCE OVER
DESIGN / DRAWN : BUILDER : SCALED MEASUREMENTS, VERIFY ALL ON SITE D Revised for Building Approval 11-02-08
ROBERT PATTERSON
DIMENSIONS AND LEVELS PRIOR TO THE
COPYRIGHT : No reproduction of all or part C Revised for Building Approval 05-02-08
QBSA Lic.No. 1095554
of this drawing may be undertaken without the COMMENCEMENT OF ANY CONSTRUCTION. ARK PROJECTS LOT 344 (No.16) SEAHORSE PL, NOOSA WATERS
fax : (07) 5449 1899 B Preliminary Approval-Revised 31-01-08
m : 0401 394 964
express written permission of the author. CONTRACTOR TO NOTIFY DESIGNER IMMEDIATELY
CLIENT JOB DESCRIPTION
ISSUE DESCRIPTION DATE
D W G N O. 7028 03
DESIGN to DETAIL OF ANY DISCREPENCIES.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2606 - Response to Information Request - Part 1 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.