BUSHFIRE PRONE AREA - MEDIUM CATEGORY
THIS PROPOSED DWELLING IS LOCATED IN A MEDIUM CATEGORY AND CONSTRUCTION IS TO COMPLY WITH
AS 3959 1999 WHICH REQUIRES LEVEL 1 CONSTRUCTION - please refer to AS 3959 1999.
SUPPORTING POST:
The requirements shall be one or a combination of the following:
a Non-combustible
b Fire retardant-treated timber for a minimum of 400mm above the finished ground levet,
c Timber mounted on galvinised metal shoes with a clearance of not less than 75mm above the adjacent finished ground level or paving level
The above do not apply where the subfloor space is totally enclosed.
WINDOWS
All openable windows, including louvres, shall be screened with corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture size of
1.8mm in such a way that the entire opening remains screened when the window is open.
EXTERNAL DOORS
Extemal doors shall be fitted with weather strips or draught excluders to prevent the penetration of build-up of buming debris beneath the door and tight
fitting door screens fitted with corrosion-resistant steel, bronze or aluminium Mesh with a maximum aperture size of 1.8mm,
vel NO WEEPHOLES
Vents and weepholes shall be protected with spark guards made from corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture size of
1.8mm.
ROOFS .
All roof sheeting shall be non-combustible and sarked (with a flammability index of not mare than 5) and fooftight glazing shall be of wired glass.
Thermoplastic material or toughened glass shail not be used as the glazing for rooflights.
All gaps under the corrugations or ribs of the roofing material where it meets the fascia or wall line shall be sealed or protected by fully sarking the roof or by
providing corrosion-resistant steel or bronze mesh, with a maximum aperture size of 1.8mm, profiled metal sheet, neoprene seal, compressed minera! wool
or similar material,
EAVES and FASCIAS
* All eaves shall be enclosed and the fascia or the gaps between the rafters sealed.
GUTTE! IPE:
Any materials or devices used to stop leaves collecting in the gutters shall have a flammability index of not greater than 5 when tested in accordance with AS.
1530.2,
SERVICE PIPES (WATER and GAS)
All exposed piping for water and gas supplies shall be metal.
Pipes of other materials shall be buried to a depth of at least 300mm below the finished ground level.
DESIGN IN ACCORDANCE WITH THE QUEENSLAND HOME
BUILDING CODE, AS 1684.2 N3 CLASSIFICATION, BUILDING
CODE OF AUSTRALIA AND THE STANDARD BUILDING BY-LAWS.
GENERAL NOTES
ALL MATERIALS SHALL BE NEW.
2 FOOTING: TO ENGINEER DETALS.
FOOTINGS 70 HAVE SOLID BOTTOMS:
AND EVEN BEARING THROUGHOUT,
a ‘SLAB: TO ENGINEER DETAILS
UNDERLAY WITH 200mm POLYTHENE
WATERPROOF MEMBRANE AND ALL
PROTRUSIONS. CAST ON 50mm SAND
BEDDING ON APPROVED FILL.
CONCRETE STRENGTH TO BE 20MPa
AT 28 FAYS. USE TERMITE CONTROL
AS PER BUILDERS SPECIFICATIONS.
4 TIMBER FRAMING: ALL FIXINGS AS
PER CONNECTION DETAILS AND GOOD
WORKMANSHIP.
5 LININGS: AS PER BUILDERS SPECIFICATIONS.
& ROOFING: COLORBOND METAL SHEET
ROOFING OR CONCRETE ROOF TILES
OVER AN APPROVED SARKING MATERIAL
AND FIXED IN ACCORDANCE WITH THE
MANUFACTURERS SPECIFICATIONS,
1 PLUMBER AND DRAINER: TO LOCAL
AUTHORITY REGULATIONS,
a ELECTRICIAN: TO LOCAL AUTHORITY
REGULATIONS.
a BRICKLAYER: GALVINISED WALL TES
1 ROW AT 2 COURSES ABOVE FLASHING
LINE AND 1 ROW IN THE SECOND LAST
BED JOINT FROM TOP OF WALL AND @
S500crs. IN BETWEEN ON EACH STUD.
PROVIDE WEEP HOLES @ 900cs. ALONG
FLASHING,
40. ALL WET AREA FLOOR AND SHOWER FLOORS
TO COMPLY WITH 8.C.A. SECTION 3.8.1,
NOTE: BUILDER TO CHECK ANO CONFIRM ALL
MEASUREMENTS PRIOR TO COMMENCEMENT
OF CONSTRUCTION. 00 NOT SCALE DRAWINGS,
WRITTEN DIMENSIONS TAKE PRECEDENCE AT
ALL TIMES. STORMWATER THROUGH P.V.C_
PIPE TO LOCAL COUNCIL REGULATIONS.
~ PAD LEVEL
RL 165.80
DRIVEWAY BY OWNER TO
COMPLY WITH COUNCIL
REQUIREMENTS
250mm MAX HEIGHT OF BATTER
WITHIN 1500mm OF BOUNDARY
en
eee
i
f
LEGEND - INTERNAL
AP - APPLIANCE CUPBOARD
BC - BROOM CUPBOARD.
C'BD - CUPBOARD
DP - DOWNPIPE
OW - DISHWASHER PROV,
Fw - FLOOR WASTE
GAS - GAS CONNECTION
HP - HOT PLATE
HWS - KOT WATER SYSTEM
L- LINEN
MH - MANHOLE
MW - MICROWAVE PROV,
OHC - OVERHEAD CUPBOARD
PTY - PANTRY
R-ROBE
REF - REFRIDGERATOR SPACE
RH - RANGEHOOD:
SH - SHELF
TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
WO - WALL OVEN
SIR - SMART ROBE,
EGEND - EXTERNAL
BV - BRICK VENEER
BL - BLOCKWORK
CO - CUSTOM ORB SHEETING
FC ~ FIBRE CEMENT SHEETING.
RH - RENDERED HEBEL PANELS,
LB -LINEA-BOARD CLADDING .
RBB - RENDERED BLUEBOARD
RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
SM - SYCON MATRIX PANELING.
T6 - TIMBER BATTENS
WB - WEATHERBOARD (AS SPEC)
SUNSHINE COAST
REGIONAL COUNCIL
PLANS APPROVED
Signature:
PROPERTY
DESCRIPTION
LOT 23. $P199350
PARISH : “"TUCHEKOI
COUNTY: MARCH
AREA: 3.511Ha
REVISIONS,
#| DATE OETAILS
R14] 25/02/09 | CLIENT CHANGES
R2}06-04-09| CLIENT CHANGES
RB] 20-04-09| CLIENT CHANGES
Ra] 30-04-09| WORKING DRAWINGS
R5|06-05-09} CLIENT CHANGES.
6 |26-08-09] INFO ADDEO
AUSMARG) —°
fawntar,
Per eT
po box 418 p (07) $442 6413,
corey q 4563 f (07) 5442 6549
QBSA 1083000
This plan remains copyright to
Ausmar Homes and may not de
used in part or in whole without
the written consent of the author.
‘© 2008 Ausmar Homes.
WRITTEN DIMENSIONS TO.
TAKE PRECEDENCE OVER SCALE
SITE PLAN
PROJECT OESCRIPTION:
Proposed Residence For:
CLIENT: .
HENRY ALEXANDER
CURREN
SITE ADDRESS:
326 LAWNVILLE ROAD
COOROY
UBD REF
DRAWN BY 6B TOVEY
baie JOB CODE
DATE HAC
26-08-09
SHEET 1 OF 41
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 4 pages
Page 2
2
a
NOTE:
GENERAL NOTES
ALL MATERIALS SHALL BE NEW.
FOOTING: TO ENGINEER DETAILS.
FOOTINGS TO KAVE SOLID BOTTOMS
ANDO EVEN BEARING THROUGHOUT.
SLAB: TO ENGINEER DETAILS
UNDERLAY WITH 200mm POLYTHENE
WATERPROOF MEMBRANE AND ALi
PROTRUSIONS. CAST ON 50mm SAND
BEDDING ON APPROVED FILL.
CONCRETE STRENGTH TO BE 20MPa
AT 28 FAYS, USE TERMITE CONTROL
AS PER BUILDERS SPECIFICATIONS.
TIMBER FRAMING: ALL FIXINGS AS.
PER CONNECTION DETAILS AND GOOD
WORKMANSHIP.
LININGS: AS PER BUILDERS SPECIFICATIONS,
ROOFING: COLORBOND METAL SHEET
ROOFING OR CONCRETE ROOF TILES
OVER AN APPROVED SARKING MATERIAL
‘AND FIXED IN ACCORDANCE WITH THE
MANUFACTURERS SPECIFICATIONS.
PLUMBER AND ORAINER: TO LOCAL
AUTHORITY REGULATIONS.
ELECTRICIAN: TO LOCAL AUTHORITY
REGULATIONS,
BRICKLAYER; GALVINISED WALL TIES.
+ ROW AT 2 COURSES ABOVE FLASHING
UNE AND 1 ROW IN THE SECOND LAST
BED JOINT FROM TOP OF WALL AND @
‘500crs. IN BETWEEN ON EACH STUD.
PROVIDE WEEP HOLES @ 90ers. ALONG
FLASHING,
ALL WET AREA FLOOR AND SHOWER FLOORS:
TO COMPLY WITH B.C,A. SECTION 3.8.1.
BUILDER TO CHECK AND CONFIRM ALL
MEASUREMENTS PRIOR TO COMMENCEMENT
OF CONSTRUCTION. DO NOT SCALE ORAWINGS,
WRITTEN DIMENSIONS TAKE PRECEDENCE AT
ALL TIMES, STORMWATER THROUGH P.V.C,
PIPE TO LOCAL COUNCIL REGULATIONS.
rr eaten Newnes ntinien mtn fier aes
soem Dm | ee | mf | | es | revere
|
_>
awe Ds) ees
\
X7000 GAL ATE! IK
TOBEP! EI
INA WITH LOCAL
IL REQUIREMENTS
7
7
x
\ 7°
- 7
4
1
}
17930 |
IAD LEVE
R.L 165.8 | |
- \ | |
ee 1 ff!
te IOTE:ALL DOWNPIPES TO BE ™_
CONNECTED TOWER -FANIS
— _
\
= \
Ss > ma
ed) _ <=
HI I |
| MHIGH Teg
o Rs
Se rerun WALLS BY Ore,
1M Hig
a \a
ENVIROCYCLE MOD!
R FLAY
%
A
2
oO
e
ay
S
z
2.
D LEVEL
L 167.80
a
“02
22
LEGEND - INTERNAL
AP - APPLIANCE CUPBOARD
BC - BROOM CUPBOARD
CBD-CUPBOARD -
OP - DOWNPIPE ‘
DW - DISHWASHER PROV,
FW - FLOOR WASTE
GAS - GAS CONNECTION
HP - HOT PLATE
HWS -HOTWATER SYSTEM
L- LINEN
MR - WANHOLE
MW - IMECROWAVE PROV.
QHC ~ OVERHEAD CUPBOARD
REF - REFRIDGERATOR SPACE.
RH - RANGEHOOD
SH - SHELF
TR - TOWEL RAL
TRH- TOILET ROLL HOLDER
UBO ~ UNDER-BENCH OVEN
WO - WALL OVEN
S/R - SMART ROBE
LEGEND - EXTERNAL -
BV - BRECK VENEER
Bl - BLOCKWORK
SUNSHINE COAST
REGIONAL COUNCILR
PLANS APPROVED
Signature: ... ST heey
pate: ZA LOBPLEP sn
CQ - CUSTOM ORB SHEETING
FG - BRE CEMENT SHEETING
- RENDERED HEBEL PANELS
LQ - LINEA-BOARD CLADDING
DReB- RENDERED BLUEBOARD.
RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
CON MATRIX PANELING
THM BER BATTENS.
B - WEATHERBOARD (AS SPEC)
ROPERTY
DESCRIPTION
LOT -23- — $P199350°
PARISH: TUCHEKO!
COUNTY: MARCH
AREA: 3.511Ha
REVIS DNS
#| DATE DETAILS:
R1) 2802/08 | CLIENT CHANGES:
R2}06-O4~09 | CLIENT CHANGES,
R3} 20-01-09 | CUENT CHANGES.
R4130-O1-09 | WORKING DRAWINGS
R5]06-O5-09 | CLIENT CHANGES
6 [26-08-09 | INFO ADDED.
AUSMARCY
ee
ar
po box 478 (07) $442 6413
Coorey 44563 f (07) $442 6549
QBSA 1083000
This plan remains copyright to
Ausmar Horas and may not be*
used in part or in whole without
the witien consent of the author.
2008 Ausmar Homes
WRITTEN DIMENSIONS TO.
TAKE PRECEDENCE OVER SCALE.
SITE PLAN
PROJECT DESCRIPTION:
Proposed Residence For.
CUENT:
HENRY ALEXANDER
CURREN
SITE ADDRESS:
326 LAWNVILLE ROAD
COOROY
UBD REF
DRAWN IY = =BTOVEY
SCALE 8 COD!
1:200 YO8 CODE
DATE HAC
26-08-09
SHEET 2 oF 11
Page 3
. 17930 LEGEND - INTERNAL
+ APPLIANCE CUPBOARI
B <D> , $ WINDOW SCHEDULE Be - BROOM CUPBOARD
. ' NO. SIZE LINTEL CBD - CUPBOARD
450 7180 4040 . | 5810 451 DP - DOWNPIPE.
<AD t - on - q wt [2/820 90x35F17 OW - DISHWASHER PROV.
430 | :
230 1800 70 4850 230 4040 350 { 5110 35¢ 22) we a ae z GAS » GAS CONNECTION
1 70 Ty 177 , wa [1516S 140x35F 17 CSc WATER system
4 231 IK. t-LINI
2310 385 1760 3655001350 4040 430 5350 0» asd WS [2407FG-27800 | t2hs3eFi7 Me MANHOLE,
—~— — 117 —_— — _t 1 a —- 1 : 7 407FG OHC - OVERHEAD CUPBOARD
= Re wit , op 7] Roe jo ----~__., A : W7 |2407FG-2/750-2 |140x35F 17 Reon
Ps | = = | (a ° { 2, o 2 fe 407FG REF - REFRIDGERATOR SPACE
: a N .
ol 2 | § >" fi | 77 i i 350x350 RENDERED BRICK PIERS Br Ak we lanai aT sy Sagrooo
2| 3 . : TR - TOWEL RAIL
Pe] She 210404 FG 770 | | \ 7 W9 |1515SW 90x35F 17 TRH - TOILET ROLL HOLDER
g wows 2 \ { | | \ . 1200 HIGH RENBERED -=4| 3 . W10|0404AW 90x35F17 UBO - UNDER-BENCH OVEN
tPot | uncer | | | ; DOUBLE BRICK WALL | a w11|2106DH 90x35F 17, SIR: SMART ROBE .
ate mas Cc 2400 ° 5 W12|2130SW 170x35F 17 LEGEND - EXTERNAL
8 7. & a! | VERANDAH “BULKHEAD 8 + W13|2436SGD 245X63LVL BY - BRICK VENEER
2 FW Cl 2 \ Se] of BL - BLOCKWORK
Z| g} * 2 i] _* > =| | 4$50X350RENDERED i gr , Wid |2436SGD 245X63.VL Ob eOsTON One SHEETING
a| & = ENS & | : Y BRICK PIER | r i W15|1812SW 90x35F 17 FG - BRE CEMENT SHEETING
ol = | 3 RENDERED DOUBLE 3 : W16|2436SGD 245X63LVL LB - LINEA-BOARD CLADDING
~ | | | = 171 1812SW 90x35F 17 RBB - RENDERED BLUEBOARD
J 8 | 10404 FG | 1100 ==! | Wi BRICK WALL | ol Ww: x RB - RENDERED BRICKWORK
, of 2 —— i = RBL - RENDERED BLOCKW(
Windows |= WAL eB | . = ~ a Rp Ne W18) 1812S S0x35F17 SM SYCON MATRIX PANELING
©| UNDER WALL So | t | 4 W19|2407FG-2/750-2 | 120x35F 17 T8 - TIMBER BATTENS
e Me @ § fe 407FG WB - WEATHERBOARD (AS SPEC)
. 2 R 4 | i=l ot | | W20|2109DH O0x36F 17 FLOOR AREAS
e@ R= wy! L L le . | | ‘ W21{2109DH 90x35F 17 Forieo ore
( $ PA I Verandah 25.04 ae
8| 3. §! = wi4 LOUNGE to jo cote eg MMS O8OBS WT nd | chones se apes
ameancunsemie| oo ch eeewabeee | BP Ste By A . NGE...... : =
2|-8& ald ‘ | _— . | o| 3| 8 Grand total 255.78 at
ne = ’ - 7 i a © Db .
° | HL, L_ 0309 RECESs| 900 y “ \ . | { 3)
be i450, 900_ 450, TounoeRspe y DINING a ! | ;
| , z =
2 | 748 3800 es N I I SUNSHINE COAST TES
oj ” \ | 7 §i ‘ \ | | *REGIONAL COUNCIL fRa[25/02/00] CLIENT CHANGES
8 IS EDIA! 7% 8 FPL 166.11 i y ot + 8 PLANS APPROVED [R2]06-04.08] CLIENT CHANGES
oj e| ~ f M Y g| \ Rest 3 : [R3|20-04.09] CLIENT CHANGES
5] $ Gm b 2400 BULKHEAD TO KITCHEN i / | Signature: .... 7A 2 Z eS 4 08 WORKING DRAWINGS!
2] | 9 R5{06-05-03| CLIENT CHANGES.
~ So \ - {HATCHED AREA) — lo . _ Z2YY%O Po 6 |26-08-09| INFO ADDED.
g I. , \ MX RATTss\ ~ RX 12 Z Date: AL OM oD aes
> te BA D- fF = se Sa Se > Ss - BED 2 Sire 8
Re fe — > N > 2
@” PANTRY BY KITCHEN . a i?) of o
NCE. a N oO
ga] Lf BG ScueRy footie sues |S ar | a8
S a ow ° OHC
7 t :
he pO box 418 For Saas oes
a 4 cooroy q 4563 5442 6549
rR ef ke v 4 oe a ESBSA 108300
BLE vaso 8 ease,
Q x 420 = var mes whol yn
g S| oases AUNDRY =I gk seep a,
ok 8{| 6& UNDER'BENCH ol o o ' © 2008 Ausmar Homes
of 8 tl ql mA wa | 21620 S| 8/ 2 , WRITTEN DIMENSIONS TO
gr ial a LZ ‘ LINEN ° = TAKE PRECEDENCE OVER SCALE
= oa
TT Tt T N
° wa FLOOR PLAN
2 k 2
BP fp maa eee o
a ok a .
+ A — :
2 > NOTE:ALL DOORS AND JOINERY TO BE AT 2400 HIGH FRAMING : N3 PROJECT DESCRIPTION:
” 4 3 STUDS — EXTERNAL & INTERNAL LOAD BEARING Proposed Residence For:
— S .
& : 70x35 MGP12 @ 450ers
INTERNAL NON-LOADBEARING CLIENT:
Br : 70x35 MGP10 @ 450crs HENRY ALEXANDER
— on “Kk STUDS @ SIDES : < 900 x2 CURREN
© 1200 x2
Pap 70 N “ @ sien rax SITE ADDRESS:
230 £300 79 6260 Zp 1400 _y 940 79 187070 900 230 PLATES EXTERNAL & INTERNAL LOADBEARING 326 LAWNVILLE ROAD
70 70 TOP PLATE : 2/70x35 MGP12 cooRoY
1240 530), 1670 70 1330 70 920 70 7060 70 940 70 2390 230 BOT PLATE : 70x35 MGP10 R
A if a 7 - ma of Ao INTERNAL NON. OADBEARING UBD REF
8070 230 2360 230 : 6590 \ BOT PLATE : 70x35 MGP 10 “DRAWN BY” —8 TOVEY
7 TRUSSES : PINE ROOF TRUSSES @ 900 ers SCALE Joa cone.
8070 2820 | 6140 450 TO MANUF. DESIGN & SPECS, REFER 4: 100
NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS : ae TO CONNECTION DETAILS FOR TIE DOWN DATE HAC
© : SMOKE ALARMS TO BE HARD WIRED IN t DETAILS. ROOF BATTENS FIXED TO TRUSS _[ 26.08.09
ACCORDANCE WITH B.C.A. 3.7.2. AS PER MANUFACTURERS SPECIFICATIONS. | sueet 3 oF {1
Page 4
aa: SE aa
~ 170.120 RL
®
169.470 RL
2700 CEILING
2400 JOINERY
SELECT METAL SHEET ROOF AT
25: ON ENGINEER DESIGNED
TRUSSES.
SELECT METAL
FASCIA/GUTTER
4010 PITCHING POINT
3360 PITCHING POINT ,
2700 CEILING
2400 JOINERY
450
PROVIDE DEEP
COLOURBOND FLASHING
TO REMOVE WATER
iE TTT [i
»
en
SUNSHINE COAST
REGIONAL COUNGIL
PLANS APPROVED
Signature: .. 0.8
LEGEND - INTERNAL
AP - APPLIANCE CUPBOARD
BC - BROOM CUPBOARD
CBD - CUPBOARD
OP - DOWNPIPE
OW - DISHWASHER PROV.
Fw - FLOOR WASTE.
GAS - GAS CONNECTION
HP - HOT PLATE
HWS - HOT-WATER SYSTEM
L-LINEN .
MH - MANHOLE,
MW - MICROWAVE PROV. |
OHC - OVERHEAD CUPBOARD.
PTY - PANTRY
R-ROBE
REF - REFRIDGERATOR SPACE
RH - RANGEHOOD
SH-~ SHELF
TR- TOWEL RAIL
TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
WO - WALL OVEN
S/R - SMART ROBE.
LEGEND - EXTERNAL
BV - BRICK VENEER
BL - BLOCKWORK
CO - CUSTOM ORB SHEETING
FC - FIBRE CEMENT SHEETING
RH- RENDERED HEBEL PANELS.
LB - LINEA-BOARD CLADDING
RBB - RENDERED BLUEBOARD
RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
SM - SYCON MATRIX PANELING
TB - TIMBER BATTENS
WB - WEATHERBOARD (AS SPEC)
REVISIONS
# | DATE
R34] 25/02/09
DETAILS
CLIENT CHANGES:
R2|06-04-09] CLIENT CHANGES
20-04-09] CLIENT CHANGES
WORKING DRAWINGS
am
(D) EAST ELEVATION
ALL FIXING AND FLASHING TO BE IN STRICT ACCORDANCE WITH THE
MANUFACTURERS DETAILS. WINDOW SIZES SHOWN ARE NOMINAL ONLY AND
ARE TO BE VERIFIED BY THE BUILDER ON SITE.
=i =i lH
=I 1 ==] et!
ie
| eee
MTT] | [==] | =} | Ft ee
I St :
ln me -
RENDERED BRICKWORK
mm - RR 166.110
06-05-09}
26-08-09)
CLIENT CHANGES:
INFO ADDED
R3|
Ra} 30-04-09)
IRS|
6
(07) 5442 6413
f (07) 5442 6549
QBSA 1083000
po box 418
cooroy q 4563
| sree
This plan remains copyright to
Ausmar Homes and may not be
used in part or in whale without
the writen consant of the author.
© 2008 Ausmar Homes
WRITTEN DIMENSIONS TO.
TAKE PRECEDENCE OVER SCALE
ELEVATIONS
PROJECT DESCRIPTION: -
Proposed Residence For:
CLIENT:
HENRY ALEXANDER
CURREN
SITE ADDRESS:
326 LAWNVILLE ROAD
COOROY
UBD REF
DRAWN BY B TOVEY
SCALE
+. 100 JOB CODE
DATE
Oa HAC
sHeET 4 OF 11
Page 5
‘ | AP - APPLIANCE CUPBOARD
f BC - BROOM CUPBOARD
C'BD - CUPBOARD
b DP - DOWNPIPE
DW - DISHWASHER PROV.
Fw - FLOOR WASTE
GAS - GAS CONNECTION
HP « HOT PLATE .
HWS - HOT WATER SYSTEM
L- LINEN
MH - MANHOLE
MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
BTY - PANTRY
R- ROBE
REF - REFRIDGERATOR SPACE
RH - RANGEHOOD
SH - SHELF
: TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
: eo ee ee , WO - WALL OVEN
ToT TS RL 168.870 SIR - SMART ROBE
LEGEND - EXTERNAL .
BV - BRICK VENEER
BL - BLOCKWORK
CO - CUSTOM ORB SHEETING
FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS
LB - LINEA-BOARD CLADDING
RBB - RENDERED BLUEBOARD
\ RB - RENDERED BRICKWORK
— ee ee ee RR, 186.110 RBL - RENDERED BLOCKWORK
_ os. SM - SYCON MATRIX PANELING
LEGEND- INTERNAL |
2700 CEILING
>
ao
uu
z
°
9
2
S
+
nN
TB - TIMBER BATTENS
—_ 77 7 | i \- WB - WEATHERBOARO (AS SPEC)
a, ell | moped | pseu =I =" le et
(Cc) NORTH ELEVATION :
SUNSHINE COAST
.| REGIONAL COUNCIL
1] PLANS APPROVED
" REVISIONS -
Signatures... A # | OATE OETAILS
| ‘ona Fei 25/0209] CLIENT CHANGES
Dates... 27, ge, on [R2|06-04-09| CLIENT CHANGES
R3] 20-04.09| CLIENT CHANGES,
- = es
IR4}30-04-09| WORKING DRAWINGS,
c IGES
SELECT METAL SHEET ROOF AT Set
25+ ON ENGINEER DESIGNED
TRUSSES:
—— =" READEREDFC SHEETING — ~ SRL 170,120
‘
ee po box 448
-—--——_ SELECT METAL RL 169.470 cooray q 4563 f (07) 5442 6549
— - — - FASCINGHTTFR_ _ _ . __ —=R_ 168.870
eee ee This plan remains copyright to
Ausmar Homes and may not be
ro 350x350 RENDERED Used in part or in whole without
BRICK COLUMN ‘the writtan consent of the author.
: © 2008 Ausmar Homes
WRITTEN DIMENSIONS TO.
TAKE PRECEDENCE OVER SCALE
ELEVATIONS
2700 CEILING
- |
|
Sel ele
a
i!
| E 5 | iE =| | | | | ~ PROJECT DESCRIPTION:
Proposed Residence For:
CLIENT:
HENRY ALEXANDER
. CURREN
(B) WEST ELEVATION
i SITE ADDRESS:
326 LAWNVILLE ROAD
' COOROY
UBD REF
DRAWN BY 8 TOVEY
SCALE
1: 100
ALL FIXING AND FLASHING TO BE IN STRICT ACCORDANCE WITH THE DATE HAC
MANUFACTURERS DETAILS, WINDOW SIZES SHOWN ARE NOMINAL ONLY AND i 26-08-09
ARE TO BE VERIFIED BY THE BUILDER ON SITE.