APPROVED PLAN
 MCU22/0007 &
  OPW22/0024
NOOSA COUNCIL
  11 MAY 2022


[OCR of page images]
 

 

 

APPROVED PLAN
MCU22/0007 &
OPW22/0024
NOOSA COUNCIL
11 MAY 2022

 

 

 

 

6 / N16 BARS
FULL LENGTH
40mm COVER

R6 HELIX —

@ 65 PITCH = ~-\_| _
eal

315¢ HUMES ~

UPVC FORMER o™~ ca

GRADE N32 --
MASS CONCRETE
TO BASE OF PILE

REINFORCING TO EXTEND ~
TO WITHIN 300 FROM —
BOTTOM OF PILES <n

 

 

 

 

 

 

 

315 DECK PILE

 

 

6 / N20 BARS
FULL LENGTH
40mm cover \

R6 HELIX

@ 65 PITCH _—w

315% HUMES

UPVC FORMER oN

 

 

 

 

R6 HELIX

@ 65 PITCH

315@ HUMES

UPVC FORMER oN

6 / N20 BARS
FULL LENGTH

& 3 7 N20 BARS
TO 2m OF TOP
40mm COVER

 

 

 

R6 HELIX 4d

@ 65 PITCH gt
Poi

bt

4000 HUMES 1-4

UPVC FORMER Ny | rt

6 / N20 BARS
FULL LENGTH

& 3 / N20 BARS
TO 3m OF TOP
40mm COVER

 

 

 

NOT APP

 

 

 

 

 

 

GRADE N32
MASS CONCRETE
TO BASE OF PILE

REINFORCING TO EXTEND
TO WITHIN 300 FROM
BOTTOM OF PILES

 

 

 

 

 

 

3158 PONTOON PILE
61kNm

 

GRADE N32
MASS CONCRETE TT
TO BASE OF PILE 4-

REINFORCING TO EXTEND :
TO WITHIN 300 FROM c
BOTTOM OF PILES qo

 

 

 

 

Ta

 

 

315¢@ PONTOON PILE
83kNm

REINFORCING TO EXTEND

 

 

 

 

4

   

GRADE N32
MASS CONCRETE
TO BASE OF PILE

WITHIN 300 FROM
BOTTOM OF PILES

 

 

 

 

 

 

 

400% PONTOON
130kNm

PILE

REINFORCING TO EXTEND
TO WITHIN 300 FROM

 

 

R6 HELIX
@ 65 PITCH NN

4008 HUMES

UPVC FORMER Ny |

 

6 / N24 BARS
FULL LENGTH

& 3 / N24 BARS
TO 3m OF TOP
40mm COVER

 

 

 

 

 

GRADE N32
MASS CONCRETE
TO BASE OF PILE

BOTTOM OF PILES

 

 

 

 

 

 

 

 

400% PONTOON PILE
172kNm

NOT APPLICABLE

 

 

 

 

 

Ee: EDGE Consulting Engineers}
1st Floor, 28 Balaclava St
Eee QLD 4102
Mob +61 447 950 427

ABN 66 099 997 985 [email protected]

TRADING AS

 

 

46kNm
E ISSUED FOR EDGE ENGINEERS WA_| 9/9/20 | TC
REV! DESCRIPTION BY | DATE |APPD)

 

 

 

CHECKED:

 

 

 

 

~ |RPEQ:

5496

 

DATE:
17/09/2020

 

THE MARINA SPECIALIST

ACN 010633119

PHONE(07) 5492 5925
ion 5492 6699

CORBOUND PARK
QLD 4551 AUSTRALIA
zy

=> SPECIALIST *

18 RON PARKINSON CRES

CuENT TC & JK St BAKER
LOT 92 (7) WITTA CIRCLE
NOOSA HEADS

TITLE:

CONCRETE INSITU PILE CONSTRUCTION

315 & 400 DIAMETER REINFORCED

 

DATE: UNITS | SCALE:

 

PROJECT:

STANDARD DRAWING

AS_1100

 

 

‘SHEET:

20/4/99 | MM
DRAWN: CHECKED: APPRD:
MA Tc

 

 

 

1:25
DRG No:

JSP—SD-045

a

: B

 

 

Used in these records

About this file

File size
6.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

MCU22 0007 & OPW22 0024 Approved Plans.pdf · 6.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.