erg

 

    

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

 

 

 

wee

wes

NOTES

LAIl work is to comply with the Queensland Plumbing & Drainage Act 2002, Building
Code of Australia, AS/NZS 3500.3 and local authority requirements.

2.These drawings are diagrammatic only. Use dimensioned building construction plans
for any set out requirements. j

3.Obtain all necessary approvals and pay all fees due.

4.The contractor is to visit the site to be fully aware of existing services and site
conditions prior to commencement of work. i

5. The contractor is to determine new drainage can be installed with correct grade and
cover prior to commencement of work.
6.Backflow prevention devices to be installed as required by the local authority.
7.Water supply pipe sizes indicated on the drawings are equivalent to type "B" copper
tube(refer table 1.1 of AS/NZS3500.1). If using an alternative material the internal

 

diameter of the pipe shall be equal to or greater than that indicated on these drawings.

ABBREVIATIONS _.

dp downpipe :

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

existing residence, nts not to scale {
2 nee uno unless noted otherwise
3 |
«
=
a
5 |
a LEGEND
Stormwater aL
a Sub soil drainage rE
Stored water
supply — et
Scale 1:250 |
I
ian bradford PROJECT T™ME CuENT DWG NO REV
aeroriresemenacacuossrs | PROPOSED ALTERATIONS HYDRAULIC SERVICES | PALTY CONSTRUCTIONS! o7955.4 | A
Bit (07) 52483875 FAX (07) 54483875 20 BAYVIEW ROAD SITE/LOCALITY PLAN, NOTES, |
BSA LICENCE NUMBER:- 1027868 NOOSA HEADS ABBREVIATIONS, LEGEND !
A ororn7 CLIENT 2 LICENCE CLASS:- HYDRAULIC SERVICES DESIGN | A3 SCALE 1:250 U.N.O. SHEET 1 OF 2
ISSUE | OATE—]-REVITON STATUS ESGNED| (INCLUDING ON SITE WASTEWATER MANAGEMENT)

 

Used in these records

About this file

File size
3.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0604 - Response to Information Request [As Published].pdf · 3.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.