Appendix A - Proposal Plans
Plans and drawings: the text below has words only, no drawings.
BUILDING HEIGHT & SETOUT NOTE LEGEND (TBA by owner) SAFETY
Confirm all dimensions on site prior to construction. SS : Single skin construction Any work performed where existing compressed sheeting is
These drawings have been prepared based on photographs WB : Weather Board external cladding present, shall have the material identified as Asbestos-free.
sketches supplied by others. BR : Timber wall brace
Dimensions and setout information shown is approximate and VJ : 19mm timber VJ internal cladding
Otherwise a licenced Asbestos compnay shall be engaged to
for development approval purposes only. AC : Asbestos Cement sheeting perform the works & approve the site as safe prior to
H
RT HR : New dowel handrail to be NCC compliant commencement of construction.
NO
Pre 1890's residence
Demolish all external walls to original
patio & recreate patio to match the Step 1130
original construction.
Existing dowel handrail
Down to remain. 100x100 Hwd
posts
2000 to US beam
existing roof line over
Open Open
Bath
(No Change) Verandah (No Change)
w.c. 2370 ceiling
Electric shr
HWS
Replace demolished
Open walls with new dowel
Slab 3030 ceiling handrail to be NCC
Replace existing Asbestos sheeting
Patio compliant and match
HR
with weatherboard external cladding Open
Bed 1
Verandah
3030 ceiling existing
to match existing.
Half wall
Raked ceiling
(No Change)
Verandah
WB
Living
WB
Raked ceiling
(No Change)
Replace existing VJ lining Replace existing VJ lining
Pre 1890's residence
Step 530
with weatherboard external with weatherboard external
cladding to match existing. cladding to match existing.
Raked ceiling
2300 ceiling
870
Demolish external walls,
WB
windows & low roof of
existing roof line over
New verandah
VJ cladding
kitchen stepout. Bed 2
beam over.
Kitchen
Extend existing slab & roof 3030 ceiling
HR
of patio to end of Kitchen. Dining 3030 ceiling
3030 ceiling
(No Change) Bed 3
Replace existing VJ lining (No Change) (No Change)
with weatherboard external
cladding to match existing.
HR
100x100 Hwd
posts
1950's extension Pre 1890's residence
Renew tank stand
Area Schedule - Proposed Second...
*To be converted to Name Area
Secondary Residence
Second Residence Floor
Exist Residence roof area 175.2 m²
(to be modified)
Habitable Rooms 82.7 m²
Entry Verandahs 39.6 m²
Floor Plan - Secondary Residence - Renovation Rear Patio 30.1 m²
1 : 100 327.6 m²
Grand total 327.6 m²
plans2go
Proposed Residences and Garage Job No PETER COOKE concept to Postal Address :
2355 Design PC 28 Kawanna St
S03 BUILDING DESIGNER
Mark Graystone and Lee Coleman Sht. no QBSA Lic : 81626 Mudjimba 4564
Date 04-12-23 Rev A Email Address :
11 Lawnville Rd [email protected]
Drawn PC Plans2go Pty Ltd
Cooroy - 'THE BUNYA HOUSE' Status Concept 0428 842316 building application www.plans2go.blogspot.com