Appendix A - Proposal Plans
Plans and drawings: the text below has words only, no drawings.
Section 1 - Residence
GENERAL CONSTRUCTION NOTES
10 These Drawings shall be read in conjunction with all other associated consultant's
drawings and specifications, and with such other written instructions as may be
issued during the course of the contract.
4000
3 3300
4 3600
5 3600
6 3300
7 All discrepancies shall be addressed by the Supervising Officer/ Superintendent
for decision before proceeding with the works.
10590 3300 All dimensions shall be verified and confirmed on-site by the contractor before
90 6810 90 1020 90 2400 90 3210 90 construction or fabrication is commenced.
The Contractor shall be responsible for maintaining the structure in a stable
90 3210 90 3510 90 1110 90 2310 90 3210 90
condition during construction and ensuring that no part may become overstressed.
Roof line over. The proposed building work and materials shall comply with the Building Act 1975
90 SHS Post and all relevant subordinate legislation; and relevant aspects of the NCC Volume 1
& 2 and with relevant SAA codes as applicable for the class of building; QDC;
90 SHS Post HR 90 SHS Post 90 SHS Post Local Government Planning Schemes & Decision Notice.
A A RESIDENCE :
Down
90 SHS Post F.L. 136.050
All construction, workmanship and materials are to be in accordance with the
90 SHS Post
Entry threshold to be current Building Code of Australia for Class 1a building.
er
H
ip
NCC compliant. 5mm GARAGE, CARPORT & SHED :
ov
3300
3300
Verandah
HR
Ramp to NSL (1 in 14)
R
r
bevelled or rounded
af
te
All construction, workmanship and materials are to be in accordance with the
te
af
step and 120mm long
ro
R
current Building Code of Australia for Class 10a buildings.
ip
ve
ramp at 1 in 8 fall
H
r
HR All dimensions are in millimeters unless noted otherwise.
24/32 oxxx 1020 glass 12/21 gas awn Written dimensions to have preference over scaled dimensions.
6750
B B All Cladding materials and elements shall be fixed in accordance with the
Step
20
12/21 gas awn
Screen to owner spec.
Ref manufacturers specifications for the appropriate internal, wet area or external
90 SHS Post 2400 head
90 SHS Post 2700Ceiling TBA ??? 90 SHS Post exposure and loading conditions and the supporting structure shown on these
90 SHS Post 2450Ceiling TBA ???
F.L. 135.100 drawings.
First Floor over.
90 90 SHS Post
3450
3450
06/24 oxxo
90 Living Dining Kitchen TERMITES
5000
Bath over 90 SHS Post Protection against subterranean termites to be in accordance with AS 3660 Part
First Floor over.
90 SHS Post
90 SHS Post 90 SHS Post FW over 1. (protection of buildings from subterranean termites.) Protection against
90 SHS Post 870x2340 csd
subterranean termites to apply to all "primary building elements". The builder is to
C C
Step
460
provide physical barriers to the entry by subterranean termites by construction of
20
WC over
CL all slabs in accordance with AS 2870 (Residential Slabs and Footings.) and AS
1550
Pty
First Floor over.
Ceiling to suit 3600 (Concrete structures code.) In addition all slab penetrations are to be
plumbing over
12/06 cas
protected using stainless steel mesh. (Termimesh or equivalent fitted to manuf.
D
3450
600
HR Mudroom WC over Linen
spec.)Regular inspections of the building are to be carried out to ensure the
820FSD
barrier has not been bridged by termites. Inspections are to be carried out as per
870x2340 csd
1900
920 2400 2421 SD S 2421 SD notices.
1500
walkway 920 Void
20
Step
20 Entry Up
over. 520
520 S Bed 2 DECKING
6840
Step
E E Isolate decking from steel joists to reduce corrosion. Refer to Bluescope CTB -
870x2340
HR 870x2340 870x2340 Cbd Cbd
2400 head 13 Technical Bulletin April 2023 – Find Bluescope CTB - 13 Technical Bulletin
90 SHS Post 90 SHS Post April 2023 – here
H
er
2550Ceiling TBA ???
ip
ov
Proposed Garage detailed separately
shr
12/06 cas
R
https://cdn.dcs.bluescope.com.au/download/corrosion-technical-bulletin-ctb-13-
r
dry
3300
3300
af
te
S 870x2340
3190
Ldy Media wc
te
af
contact-with-timber
ro
R
Bathfw
ip
ve
wm
H
r
90 SHS Post Legend Walls
fw w.c.
F 12/06 cas 06/24 oxxo 06/15 xo 06/09 xo 06/21 xox
F 90mm Steel frame with 90x45
cypress stud infill frame Legend Fittings & Fixtures
Glass Screen
90 SHS Post BB Breakfast Bar
90 SHS Post
Roof line over. BR Broom Cupboard
90 SHS Post 90 SHS Post Cupd. Cupboard with shelves & doors
9073090 1200 90 1020 90 90 SHS Post DW Dishwashing
1.2m circulation
fw Floor Waste
90 2315 90 4785 90 900 90 1030 90 1020 90 3210 90 space for the WC Legend Windows Doors
5000
hws Hot Water System
HP Hot Plates
90 3910 90 1810 90 5290 90 2020 90 1020 90 3210 90 awn Awning
MV Mechanical Ventilation
Waterproof construction csd Cavity Sliding Door
NORTH 3910 13890 to wet areas to be cas Casement
MW
Ref
Microwave
Refrigerator
NCC CL 10.2 compliant. fg Fixed Glass
RH Range Hood
Hobless shower sgd Sliding Doors
SKL Skylight
3 4 5 6 7 xxo opening/opening/fixed glass
(viewed from outside)
t
WM
Laundry tub
Clothes Washing Machine
obs obscure glass
S Smoke Detector
2 Ground Floor - Primary Residence - Proposed
1 : 100
plans2go
Proposed Residences and Garage Job No PETER COOKE concept to Postal Address :
2355 Design PC 28 Kawanna St
Mark Graystone and Lee Coleman Sht. no 05 BUILDING DESIGNER
QBSA Lic : 81626 Mudjimba 4564
Date 04-12-23 Rev A Email Address :
11 Lawnville Rd [email protected]
Drawn PC Plans2go Pty Ltd
Cooroy - 'THE BUNYA HOUSE' Status Concept 0428 842316 building application www.plans2go.blogspot.com