TIE-DOWN
WIND CLASSIFICATION - N3
ROOF - METAL ROOF BATTEN SPACING - 900 TRUSS/RAFTER - JD4
UPLIFT LOAD WIDTH - 5642 BEARER SPAN - N/A WALL FRAMING - JD4
TRUSS/RAFTER SPACING - 600 BATTENS - J2 JOISTS/BEARERS - JD4
UPLIFT UPLIFT
TABLE REQ'D FIGURE ACHV'D
No (KN) No (KN)
1/75mm No 14 TYPE 17 SCREW
(GENERAL AREA & ROOF EDGES)
Batten to truss
1.5
(ROOF 9.25(d) 4.5
EDGES)
9.14
0.85
(GENERAL 9.25(d) 4.5
AREA)
2/FRAMING ANCHORS 30 X 0.8mm G.I.STRAP Truss to top plate
AT EACH TRUSS WITH WITH 2/2.8mm DIAM NAILS
4/2.8 mm DIAM NAILS EACH END AT 450 C/S
EACH END 4.5 9.21(b) 5.9
9.13
Top plate to stud
9.13 3.3 9.19(d) 3.5
Stud to bottom plate
9.13 3.3 9.19(d) 3.5
1/M10 BOLT AT FLOOR JOIST
MAX 1800 C/S
Bottom plate to slab/bearer
9.13 13.1 9.18(d) 15.0
Floor joist to bearer
N/A
Bearer to column
N/A