                Criteria                   Planning Scheme           Proposal                         Complies

                Boundary setbacks
                 • Frontage                6 metres min              6 metres                         X
                 • Side (north)            1.5/2.0/2.5 metres min    1.5/2.0/2.5 metres               X
                 • Side (south)            1.5/2.0/2.5 metres min    1.5/2.0/2.5 metres               

                 • Rear                    6 metres min              > 6 metres                       

                Basements setback
                •       Frontage           6 metres min              < 6 metres (Retaining walls)     X
                •       Side (north)       1.5 metres min            1.5 metres                       
                •       Side (south)       1.5 metres min            0.75 metres                      X
                •       Rear               6 metres min              > 6 metres                       

                Roof Form                  0 rooftop terraces        2 rooftop terraces               X

                Communal     swimming 12 metres min      1.7 metres                                   X
                pool setback
                                      +5 metre landscape
                                      buffer

                Landscaping                40% of site area          > 40%                            
                Soft landscaping           60% of landscaping        > 60%                            

                Private open space         25m2 @ground level        > 25m²                           

                Carparking                 2 covered, 1 additional 4 covered                          
                                           min


               Storeys and Building Height
               Acceptable Outcome AO8.1 of the Medium Density Residential Zone Code requires buildings and
               structures to be no more than 8 metres in building height. The submitted architectural plans
               indicates that the building achieves the 8 metre building height, however, there appear to be
               discrepancies between the natural ground level shown on the architectural plan, the levels on the
               submitted survey plan, and the existing conditions of the site.
               As a result of the discrepancies, a further advice letter was issued to the applicant to address this
               issue, however, the natural ground level on the architectural plan appeared to change and increase
               in height with each revision. The plan revisions are shown in the following figures.




Document Set ID: 22625793
Version: 14, Version Date: 03/04/2024

Used in these records

About this file

File size
12.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Delegated Report - Code - MCU22 0139 CHANGED FROM COUNCIL REPORT [As Published].pdf · 12.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.